NEC PlasmaSync 5000W User Manual page 54

Nec plasmasync 5000w: users manual
Hide thumbs Also See for PlasmaSync 5000W:
Table of Contents

Advertisement

18. GREEN Gain Data
Function
The external control equipment changes the GREEN Gain Data of the PlasmaSync 5000W.
Transmission Data
DFH 80H
60H
7FH
DATA00: USER PICTURE Gain Flag
DATA01: GREEN Gain Flag
DATA02: GREEN Gain 1 (Bias)
DATA03: GREEN Gain2 (Drive)
ACK
7FH
60H
80H
7FH
DATA00: USER PICTURE Gain Flag
DATA01: GREEN Gain Flag
19. BLUE Gain Data
Function
The external control equipment changes the BLUE Gain Data of the PlasmaSync 5000W.
Transmission Data
DFH 80H
60H
7FH
DATA00: USER PICTURE Gain Flag
DATA01: BLUE Gain Flag
DATA02: BLUE Gain1(Bias)
DATA03: BLUE Gain2(Drive)
ACK
7FH
60H
80H
7FH
DATA00: USER PICTURE Gain Flag
DATA01: BLUE Gain Flag
04H
DATA00 to DATA03 CKS
01H
02H
F0H: -16
FFH: -1
00H: 0
10H: +16
F0H: -16
FFH: -1
00H: 0
10H: +16
02H
DATA00 DATA01
01H
02H
04H
DATA00 to DATA03 CKS
01H
03H
F0H:-16
FFH:-1
00H: 0
10H: +16
F0H:-16
FFH:-1
00H: 0
10H:+16
02H
DATA00 DATA01
01H
03H
CKS
CKS
47