Impacts or damages caused by over-voltages or electromagnetic fields which are beyond the standards and specifications in the technical data. Damages caused by improper handling, e. g. by wrong tools, incorrect installation, incorrect electrical installation (false polarity) etc. Damages which are caused by using the device beyond the specified operation conditions. page – aem.eco...
Their horizontal distance should be approximately 1.5 m. The two sensors must be staggered vertically so that the lower edge of the upper wind speed sensor is 0.1 to 0.5 m above the upper edge of the lower wind direction sensor. aem.eco page –...
The material thickness for mounting the sensor between the nuts must not exceed 10 mm. Remove the thread nut from the sensor. The sensor with cable-plug connection is led without cable into the bore and fastened by the opposite side with the loose nut as under I.3. page – aem.eco...
Please make sure the cable is protected from humidity on the side of the data processing system. Generally, Pg sockets that use a rubber joint to prevent humidity from penetrating into the terminal box of the data processing system provide sufficient protection. Example: Cable run by an EMC fair Pg-socket aem.eco page –...
For an environmentally friendly recycling and disposal of your old device, contact a certified disposal company for electronic waste. Outside the EU Please follow the regulations in your country regarding the appropriate disposal of waste electronic equipment. page – aem.eco...
Flame resistance of the cable: acc. to UL Style 20549 DIMENSIONED DR AWING 44,5 Dimensional drawings Material Maße ohne Toleranzangabe nach Oberfläche Maßs DIN ISO 2768-m Datum Name Benennung Revis Bearb. 01.11.2022 curdt Maßzeichnung - Kabel Gepr. aem.eco page – Norm. Artikelnummer...