The Perfect Weather Sensor
For industrial use as well as under extreme environmen-
tal conditions
6+1 parameters in one and at the same time
 Wind direction
 Wind speed
 Air temperature
 Air humidity
 Barometric pressure
 Global radiation
 Dew point temperature (calculated value)
With independent, integrated sensors for high accura-
cies of each individual parameter
Without movable measuring elements, i. e. no abrasion,
low maintenance and very easy to service
Applications
Land applications under any conditions
Wind turbines
Railway line monitoring
Traffic meteorology
Weather services and Offices for the Environment
Chemical and industrial facilities
Power plants, sewage plants and landfills
(16480) u[sonic]WS7
Advantages at a Glance
Extremely robust, compact weather sensor with high-
quality, pollutant-resistant housing made of anodized
aluminium
Ideal for use in extreme environmental conditions, e.g.
deserts, tropics, high mountains
Version with integrated heating system for year-round
icing-free operation
Lamella shelter for accurate measurements of the
temperature-humidity sensors
ASCII data protocol according to NMEA 0183
Power supply 6...60 VDC with integrated overvoltage
protection
Storage, evaluation and display of the measured values
using the "MeteoWare CS" evaluation software
Easy, space-saving mounting on 50 mm standard pipe
Manual
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Lambrecht Meteo u[sonic]WS7 and is the answer not in the manual?

Questions and answers

Summary of Contents for AEM Lambrecht Meteo u[sonic]WS7

  • Page 1 Manual Weather Sensor u[sonic]WS7 The Perfect Weather Sensor Advantages at a Glance ■ For industrial use as well as under extreme environmen- ■ Extremely robust, compact weather sensor with high- tal conditions quality, pollutant-resistant housing made of anodized aluminium ■ 6+1 parameters in one and at the same time ■...
  • Page 2: Table Of Contents

    Manual Weather Sensor u[sonic]WS7 Contents Introduction Warranty Setting to work Installation conditions 2.1.1 Generally Tools and installation aids Unpacking the sensor Goods inspection Power supply Installation procedure (short instruction) Mounting 2.7.1 North alignment of wind sensor 2.7.2 Power and signal connection 2.7.3 Safety regulations Maintenance...
  • Page 3: Introduction

    Manual Weather Sensor u[sonic]WS7 Introduction Advantages of the sensor: • Apart from the sensors for wind speed and direction the The sensors of the u[sonic] family are very robust, compact compact housing also contains built-in sensors for air and extremely reliable. temperature, relative humidity, barometric pressure and The sensors embody the experience of more than 150 years global radiation.
  • Page 4: Tools And Installation Aids

    Manual Weather Sensor u[sonic]WS7 Mounting The place of installation should not be in the operation fields of radar devices (radar scanners The sensor can be installed on a standard pipe with an outer or radar transmitters), generators or antennas. We diameter of 50 mm and an inner diameter of maximum 40 mm.
  • Page 5: Power And Signal Connection

    Manual Weather Sensor u[sonic]WS7 2.7.2 Power and signal connection Maintenance The u[sonic]WS7 sensor requires a 8-pole M16 plug connec- Regular maintenance and calibration tor. The cable shield should be connected with both ends at the ground wire (PE). The sensor u[sonic]WS7 is service reduced and designed for a very long lifetime.
  • Page 6: Dimensional Drawings And Electrical Connections U[Sonic]Ws7

    Manual Weather Sensor u[sonic]WS7 Dimensional drawings and electrical connections u[sonic]WS7 Ø Stecker Pinbelegung Male side pin assignment Pinbelegung RS Pinbelegung Kabelfarbe Pin assignment Pin assignment Cable color SDI-12 32.16470.060000 RS 485 SDI-12 32.16470.060000 n.c. n.c. n.c. n.c. schwarz black Data - SDI-12 Data braun Data -...
  • Page 7: Data Protocols U[Sonic]Ws7

    Manual Weather Sensor u[sonic]WS7 Data protocols u[sonic]WS7 Global radiation Example of data sequence with comma separated NMEA Communication parameters fields: $WIXDR,,,500.0,W,01*CS<CR><LF> Baudrate: 4800 Baud field delimiter: , (comma) Data Bits: Parity Bit: None (none) header: $WIXDR Stop Bits: 1 (or more) global radiation: 0.0...1600.0 Handshake: without W: global radiation in W/m²...
  • Page 8: Modbus Data Protocols U[Sonic]Ws7

    Manual Weather Sensor u[sonic]WS7 Modbus data protocols u[sonic]WS7 This manual covers the general Modbus specification common to all Modbus sensors from LAMBRECHT meteo. The manual allows easy operation of all LAMBRECHT meteo Modbus sensors. Some sensors of the Modbus family offer additional regis- ters and functions, which are described in separate documents via the registers and functions described here.
  • Page 9: Instantaneous Values / Realtime Values (Input Register)

    Manual Weather Sensor u[sonic]WS7 Instantaneous values / realtime values (Input Register) The following measured values are provided by LAMBRECHT meteo sensors. Register address Parameter name Unit Divisor Quantity of registers Access type 30001 Wind speed Read only 30201 Wind direction °...
  • Page 10: Descriptive Sensor Parameter Registers (Holding Register)

    Manual Weather Sensor u[sonic]WS7 Example: Retrieve wind speed (min. max. avr.) and erase the register content Transmission Source Dest Function Func Desk Checksum Query => Master Slave 1 Read Input Register (4) Address=30004, Quantity of Register=1 OK:86A Transmission Source Dest Function Func Desk Data...
  • Page 11: Sensor Parameters / Configuration-Parameters

    Manual Weather Sensor u[sonic]WS7 Sensor parameters / configuration-parameters Register Parameter name Allowed values Quantity of registers Access type 40001 Modbus device address Write only 40200 Baud rate 96 = 9600 Write only 192 = 19200 384 = 38400 40201 Parity 1 = even Write only 0 = none...
  • Page 12: Sdi-12 Interface

    Manual Weather Sensor u[sonic]WS7 SDI-12 Interface SDI-12 has to be preconfigured ex works. Please specify when ordering: Id-No. 97.16470.000002 Configuration SDI-12 The communication using SDI-12 protocol via SDI-12 interface is based on the ‘SDI-12 A Serial-Digital Interface Standard for Microprocessor-Based Sensors, Version 1.4, 2017’. The u[sonic] can be used in bus mode parallel to other u[sonic]. The following subset of SDI-12 commands were implemented into the u[sonic].
  • Page 13 Manual Weather Sensor u[sonic]WS7 Example: Command Answer 0<CR><LF> 1<CR><LF> Send Identification - aI! The command aI! is used to ask the sensor for its model number and firmware version. Syntax Command Answer a14LMGmbH151647011.1<CR><LF> a – Sensor address a – Sensor address I –...
  • Page 14 Manual Weather Sensor u[sonic]WS7 Example: Command Answer 0A1! 1<CR><LF> Start Concurrent Measurement - aC! The "Concurrent Measurement" enables the data logger to measure simultaneously with multiple sensors on the same bus. The "aC!" command requests the sensor to process the available measurement data and write them to an output string. Unlike the standard sensors described in the SDI-12 documentation, the u[sonic] measures continuously.
  • Page 15 Manual Weather Sensor u[sonic]WS7 Send Data - aD0! The data requested by the sensor with the commands "C" or "M" can be retrieved with the command "aD0!". The sensor uses the corresponding signs ("+" or "-") as field separators. If the data was requested with a "CC" or "MC" command, a CRC checksum is also returned.
  • Page 16 Manual Weather Sensor u[sonic]WS7 Syntax for measurements with command "aC!" or "aM!" Command Answer aD0! a<values><CR><LF> a – Sensor address a – Sensor address D – Command ‘Send Data’ <values> – Requested data separated by 0 – Request for the data in buffer 0 resp.
  • Page 17: Technical Data

    Manual Weather Sensor u[sonic]WS7 Technical data Dimensions: H 284 mm; Ø 199 mm; mast adapter Ø 50 mm for mounting on standard pipe u[sonic]WS7 (16480) Weather Sensor Housing: seawater resistent aluminium; IP 66, IP 67 ID 00.16480.001000 Weight: approx. 3.4 kg Range of application: -40...+70 °C (heated: -50...+70 °C);...