Drawers Not Able To Close Completely; Drawers Uneven - Sub-Zero Wolf ICB700 Series Service Manual

Base unit
Table of Contents

Advertisement

International Integrated
International Integrated
PROBLEM
S. Lights Stay ON when
Drawers Closed - (May be
Accompanied by /Drawer
Ajar Alarm Bell)
T. Drawers Not Able to Close
Completely
U. Drawers Uneven
(ICB700 Base)
(ICB700 Base)
POSSIBLE CAUSE
Door or Drawer Ajar
a. Food product obstruction
b. Drawer closer tripped backwards
Faulty Light Switch
Food Product Obstruction
Drawer Closer Tripped Backwards
Improper Drawer Panel Installation
Unit Not Level
8-15
Series
Series
Troubleshooting Guides
TEST / ACTION
a. Move obstruction.
b. Trip drawer closer forward
Check operation of light switches, lights off
when switch is depressed. Replace switch
if defective. (NOTE: Two light switches in
unit)
Move obstruction.
Trip drawer closer forward
The drawers are non-adjustable. Instead,
the drawer panels must be adjusted if there
is an alignment problem. Refer to the
Installation Manual and/or installation video
for panel installation and adjustment.
Check levelness of unit. If un-level, turn
front leveling legs counterclockwise to raise
front or clockwise to lower it. Rear levelers
are adjusted from front of base by turning
adjusting screw clockwise to raise rear or
counterclockwise to lower it. Refer to the
Installation Manual and/or installation video
for complete installation and leveling instruc-
tions.