Download Print this page

Datalogic S5N-Px-PK Series Instruction Manual

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1

Quick Links

This product is covered by one or more of the following patents.
European Patent 1,111,690 B1
S5N-Px-...-PK/NK SERIES
INSTRUCTION MANUAL
CONTROLS
OUTPUT LED (S5N-...A00/B01/C01/C10/F00)
The yellow LED ON indicates that the NO output status is closed.
POWER ON LED (S5N-...G00)
The green LED indicates that the sensor is operating.
TRIMMER (S5N-...B01/C01)
The trimmer can be used to adjust sensitivity; the operating distance increases
turning the trimmer clockwise.
WARNING: The trimmer rotation is limited to 270°.
Do not apply excessive torque beyond the maximum and minimum pos it i o n s
(max 40 Nmm).
INSTALLATION
The sensor can be fixed by means of the M18x1 threaded body through
a  18mm hole, using the specific washer and the two CH.24 nuts
(1.5Nm maximum tightening torque) or CH.22 nuts, h=8mm, (2Nm
maximum tightening torque) enclosed. Alternatively, the sensor can be
mounted through the two housing's holes using two screws (M3x22 or
longer) and washer.
Amongst the various possible solutions, we suggest to choose the
combination that offers the best visibility of the signalling LEDs and the
easiest access to the trimmer.
Various
orientable
fixing
brackets
are
available to ease the sensor positioning
(please refer to the accessories listed in the
general catalogue). The operating distance is
measured from the front surface of the sensor
lens.
C models: To improve the detection, the
object has to be moved closer or further away
from the front surface of the sensor lens.
In case of lateral translation, the object must move as indicated in the
figure.
CONNECTIONS
The connections are compliant to the EN 60947-5-2 standard.
S5N-...A00/B01/C01/C10/F00
S5N-...G00
BROWN
BROWN
1
1
+
+
10 ... 30 Vdc
2
WHITE
WHITE
2
*
DARK- / LIGHT+
BLACK
4
BLACK
4
N.O. OUTPUT
BLUE
3
BLUE
3
0 V
*
in case of white wire or pin 2 not connected the sensor works in
LIGHT mode for proximity models (C01/C10) and in DARK mode for
retroreflex (A00/B01) and receiver (F00).
M12 CONNECTOR
S5N-... A00/B01/C01/C10/F00
S5N-...G00
Power supply:
Ripple:
Current consumption
(output current excluded):
Outputs:
Output current:
Capacitive load:
Output saturation voltage:
Response time:
Switching frequency:
Indicators:
Setting:
Operating temperature:
Storage temperature:
Insulating strength:
10 ... 30 Vdc
Insulating resistance:
TEST +
Operating distance
TEST -
(typical values):
0 V
Emission type:
Ambient light rejection:
Vibrations:
Shock resistance:
white wire or pin 2 connected to +10...30V LIGHT mode; to 0V DARK mode
LIGHT/DARK selection:
white wire or pin 2 not connected
Housing material:
Lens material:
Mechanical protection:
Connections:
Weight:
AtEx 2014/34/EU
DIMENSIONS
TECHNICAL DATA
S5N-PA AXIAL VERSION
S5N-PR RADIAL VERSION
10 ... 30 Vdc (limit values)
2 Vpp max.
30 mA max.
N.O.; PNP or NPN (short circuit protection)
100 mA max.
C
<= 1.5 uF @24V, I
= 100mA
max
load
C
<= 3.5 uF @24V, I
= 10mA
max
load
2 V max.
1 ms (4 ms mod.F00)
500 Hz (120 Hz mod.F00)
OUTPUT LED (YELLOW) mod.G00 excluded
POWER ON LED (GREEN) (mod.G00)
sensitivity trimmer (mod.B01/C01)
-25 ... 55 °C
-25 ... 70 °C
500 Vac 1 min., between electronics and housing
>20 M 500 Vdc, between electronics and housing
A00: 0.1...3.5 m on R2
A00: 0.1...2.5 m on R2
B01: 0.1...2.5 m on R2
B01: 0.1...2.0 m on R2
C01: 1...40 cm
C10: 0...10 cm
F00/G00: 0...18 m
F00/G00: 0...15 m
RED (660 nm) (mod.B01) / INFRARED (880 nm) (mod.A00/C01/C10/G00)
according EN 60947-5-2
0.5 mm amplitude, 10 ... 55 Hz frequency, for every axis (EN60068-2-6)
11 ms (30 G) 6 shock for every axis (EN60068-2-27)
LIGHT mode (mod.C01/C10);
DARK mode (mod.A00/B01/F00)
PBT
PMMA
IP67
2 m cable  4 mm / M12 - 4 pole connector
75 g. max. cable vers. / 25 g. max. connector vers.
II 3D EX tc IIIC IP67 T85°C
Setting of S5N-...A00/B01
Position the sensor and reflector on opposite sides.
Moving the sensor both vertically and horizontally, determine the power
on and off points of the yellow LED (OUT) and then mount the sensor in
the middle of the points defined.
B01 Model: Turn the sensitivity trimmer to the maximum position.
If necessary reduce sensitivity in order to detect very small targets. In
order to improve alignment, repeat the procedure detailed above whilst
progressively reducing the sensitivity.
Setting of S5N-...F00/G00
Position the sensors on opposite sides.
Move the sensor both vertically and horizontally, determine the power on
and off points of the yellow LED (OUT) and then mount the sensor in the
middle of the defined points.
Setting of S5N-...C01
Turn the sensitivity trimmer to minimum: the yellow
LED is OFF.
Position the target to detect in front of the sensor.
Turn the sensitivity trimmer clockwise until the yellow
LED turns ON (Target detected state, pos.A).
Remove the target, the yellow LED turns OFF.
Turn the sensitivity trimmer clockwise until the yellow LED turns ON
(Background detected state, pos.B).
The trimmer reaches the maximum level if the background is not
detected.
Turn the trimmer to the intermediate C position, between the two A and
B positions.
Setting of S5N-...C10
The operating distance range of these sensors is factory preset: please
consider this feature when positioning.
TEST FUNCTION (S5N-...G00)
The TEST+ and TEST- inputs can be used to inhibit the emitter and
verify that the system is correctly operating.
The receiver output should switch when the test is activated while the
beam is uninterrupted. The inputs activating voltage range is 10 ... 30
Vdc, whilst respecting the polarity.
The emission is switched off connecting TEST+ to Vdc and TEST- to 0V.
Datalogic S.r.l.
Via S. Vitalino 13 - 40012 Calderara di Reno - Italy
Tel: +39 051 3147011 - Fax: +39 051 3147205 - www.datalogic.com
Helpful links at www.datalogic.com:
The warranty period for this product is 36 months. See General Terms and Conditions
of Sales for further details.
C01: 1...30 cm
C10: 0...8 cm
© 2021 Datalogic S.p.A. and/or its affiliates  ALL RIGHTS RESERVED.  Without
limiting the rights under copyright, no part of this documentation may be reproduced,
stored in or introduced into a retrieval system, or transmitted in any form or by any
means, or for any purpose, without the express written permission of Datalogic S.p.A.
and/or its affiliates. Datalogic and the Datalogic logo are registered trademarks of
Datalogic S.p.A. in many countries, including the U.S.A. and the E.U. All other trademarks
and brands are property of their respective owners. Datalogic reserves the right to
make modifications and improvements without prior notification.
SETTING
A
C
B
MAX
MIN
Contact Us, Terms and Conditions, Support.
For information about the disposal of Waste Electrical and
Electronic Equipment (WEEE), please refer to the website at
www.datalogic.com.
821007360 Rev.A

Advertisement

loading

Summary of Contents for Datalogic S5N-Px-PK Series

  • Page 1 2 m cable  4 mm / M12 - 4 pole connector Connections: Datalogic S.p.A. in many countries, including the U.S.A. and the E.U. All other trademarks and brands are property of their respective owners. Datalogic reserves the right to Weight: 75 g.
  • Page 2: Installation

    Hell-/Dunkelumschaltung: (A00/B01) und Einweglichschranken (F00). weißer Draht oder Pin 2 nicht angeschlossen: Hellschaltung bei Mod. C01/C10 und © 2021 Datalogic S.p.A. und/oder die Tochtergesellschaften  ALLE RECHTE VORBEHALTEN .  Dunkelschaltung bei Mod. A00/B01/F00 M12-STECKERVERSION Ohne die im Urheberrecht festgelegten Rechte einzuschränken, darf kein Teil dieses Dokuments Gehäusematerial:...
  • Page 3: Manuel D'instructions

    Sélection CLAIRE/SOMBRE: Fil blanc ou broche 2 non connecté LIGHT ON (mod. C01/C10); DARK ON (mod.A00/B01/F00) © 2021 Datalogic S.p.A. et/ou ses filiales  TOUS DROITS RÉSERVÉS.  Aucune par t ie d e S5N-… A00/B01/C01/C10/F00 S5N-…G00 Boîtier: cette documentation ne peut être reproduite, stockée ou introduite dans un système de...
  • Page 4: Manuale Istruzioni

    11 ms (30 G) 6 shock per ogni asse (EN60068-2-27) filo bianco o pin 2 connesso a +10…30V modo LUCE; a 0V modo BUIO © 2021 Datalogic S.p.A. e/o le sue consociate  TUTTI I DIRITTI RISERVATI.  Senza Selezione BUIO/LUCE: filo bianco o pin 2 non connesso modo LUCE (mod.
  • Page 5 N.O. OUTPUT TEST - TEST - Via S. Vitalino 13 - 40012 Calderara di Reno - Italy 蓝色 蓝色  电话:+39 051 3147011 - 传真:+39 051 3147205 - www.datalogic.com BLUE BLUE 绝缘电阻: >20 M 500 Vdc,电子设备与外壳之间 www.datalogic.com 上的网站帮助链接:联系我们、条款和条件、支持。 A00:R2 上 0.1…3.5 m A00:R2 上...
  • Page 6: Warranty

    Prodotti dopo la vendita. Il Periodo di Garanzia Beispiel aber nicht nur Brände, Wasserschäden, Überschwemmungen, ; (10) tout consommable ou équivalent (par exemple, des câbles, les sarà di tre anni dalla data di spedizione da parte di Datalogic, se non sonstige Naturkatastrophen,...
  • Page 7 CE Compliance CE marking states the compliance of the product with essential requirements listed in the applicable European directive. Since the directives and applicable standards are subject to continuous updates, and since the manufacturer promptly adopts these updates, therefore the EU declaration of conformity is a living document. The EU declaration of conformity is available for competent authorities and customers through the manufacturer’s commercial reference contacts. Since April 20th, 2016 the main European directives applicable to the products require inclusion of an adequate analysis and assessment of the risk(s).

This manual is also suitable for:

S5n-px-nk series