Detector Installation - DSC LC-171 Installation Instructions & User Manual

Dual-tech motion sensor (dual pir & microwave) with pet immunity
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
6

Detector Installation

Important! Prior to installation, read both "Operation" and "Selecting the mounting
location" sections carefully.
1. Install the detector in such manner that the intruder
is most likely to cross the detection area from side to
side.
3. Make sure to attach the metal bracket to a leveled
straight and firm wall, leaving 15cm (5.9 inches) from
the top and 15cm from both sides, for easy installation
and maintenance.
5. Open the detector unwinding the bottom screw.
7. Release the detector body from the metal bracket
by pulling the detector out and up.
2. The detector is to be installed at height of 0.8 to 1.5
meter (2.6 to 4.9 ft.), ideally 1.2m (4 ft.)
4. Rotating the detection beam may be required for
guarding a side window opening while the detector is
installed facing another direction.
6. Release the rear metal bracket by unwinding
internal bottom screw.
8. Attach the rear bracket to the wall or a pole using
mounting screws or metal bands.