Indoor unit
KHS1232
Outdoor unit
CH1232
208V single phase 60Hz
Rating Capacity: 11,500 BTU/h
Evaporator
Ent. Temp. °F (°C)
WB
DB
59
72 (22.2)
(15.0)
76 (24.4)
80 (26.7)
84 (28.9)
88 (31.1)
63
72 (22.2)
(17.2)
76 (24.4)
80 (26.7)
84 (28.9)
88 (31.1)
67
72 (22.2)
(19.4)
76 (24.4)
80 (26.7)
84 (28.9)
88 (31.1)
71
72 (22.2)
(21.7)
76 (24.4)
80 (26.7)
84 (28.9)
88 (31.1)
75
76 (24.4)
(23.9)
80 (26.7)
84 (28.9)
88 (31.1)
TC
: Total Cooling Capacity (BTU/h)
SHC : Sensible Heat Capacity (BTU/h)
KW : Compressor Input (kW)
Rating conditions (* mark) are: Outdoor ambient temperature
Air Flow Rate: 330 CFM
Condenser
Ambient Temp. °F (°C)
75
85
(23.9)
(29.4)
TC
11,390
10,870
KW
0.88
0.96
SHC
8,390
8,130
SHC
9,470
9,210
SHC
10,610
10,340
SHC
11,390
10,870
SHC
11,390
10,870
TC
11,780
11,410
KW
0.89
0.97
SHC
7,050
6,880
SHC
8,130
7,960
SHC
9,260
9,090
SHC
10,350
10,180
SHC
11,430
11,260
TC
12,100
11,900
KW
0.89
0.98
SHC
5,660
5,580
SHC
6,750
6,670
SHC
7,880
7,800
SHC
8,970
8,880
SHC
10,050
9,970
TC
12,480
12,270
KW
0.90
0.99
SHC
4,240
4,160
SHC
5,330
5,250
SHC
6,460
6,380
SHC
7,540
7,460
SHC
8,630
8,550
TC
12,720
12,580
KW
0.92
1.01
SHC
3,910
3,860
SHC
5,040
5,000
SHC
6,130
6,080
SHC
7,210
7,170
Indoor unit entering air temperature
8
95
105
115
(35.0)
(40.6)
(46.1)
10,350
9,760
8,970
1.04
1.13
1.24
7,870
7,580
7,200
8,950
8,670
8,290
10,090
9,760
8,970
10,350
9,760
8,970
10,350
9,760
8,970
10,960
10,360
9,550
1.06
1.15
1.27
6,670
6,400
6,040
7,750
7,490
7,120
8,890
8,620
8,260
9,970
9,700
9,340
10,960
10,360
9,550
*11,500
10,870
10,120
1.07
1.17
1.29
5,410
5,150
4,850
6,500
6,230
5,930
7,630
7,370
7,060
8,710
8,450
8,150
9,800
9,540
9,230
11,960
11,420
10,750
1.09
1.20
1.32
4,040
3,840
3,590
5,130
4,930
4,680
6,260
6,060
5,810
7,350
7,140
6,900
8,430
8,230
7,980
12,310
11,870
11,390
1.10
1.23
1.35
3,770
3,620
3,460
4,900
4,750
4,590
5,990
5,840
5,680
7,070
6,920
6,760
95°F DB
80°F DB/67°F WB