Remote Video Link Transmitter for 6300B Box PCs and 6300T Box Thin Clients Installation Instructions
European Union Directive and UKCA Compliance
This equipment meets the European Union Directive and UK requirements when installed within the European Union or EEA regions and have the CE marking. A copy of the
declaration of the conformity is available at rok.auto/certifications.
ATTENTION: This equipment is intended to operate in an industrial or control room environment, which uses some form of power isolation from the
public low-voltage mains. Some computer configurations cannot comply with the EN 61000-3-2 Harmonic Emissions standard as specified by the EMC
Directive of the European Union.
ATTENTION: All I/O cables must be used only indoors.
Unpack your RVL Transmitter
Before you unpack your RVL transmitter, inspect the shipping carton for damage. If damage is visible, immediately contact the shipper and request
assistance. If there is no visible damage, proceed with unpacking.
Your RVL transmitter ships with the following items:
RVL transmitter, 6300V-RVLDV-RTX
DC terminal block kit
Mounting kits
- Book mount kit: bracket (quantity 1) and screws (quantity 2)
- Wall mount kit: brackets (quantity 2) and screws (quantity 4)
- DIN rail mount kit: rail hook (quantity 1) and screws (quantity 2)
Installation Site Guidelines
Follow these installation site guidelines to make sure that your RVL transmitter provides service with excellent reliability.
WARNING: This RVL transmitter is:
• suitable for use in CLASS I, DIVISION 2, GROUPS A, B, and D Hazardous Locations or Non-hazardous Locations only.
• considered open equipment, which means that it may only be integrated in housings or cabinets where the front panel can be accessed for operation.
When choosing the installation site, consider the following:
- The site must have sufficient power.
- The site must be indoors and non-hazardous.
- The site must not expose the RVL transmitter to direct sunlight.
The maximum operating ambient temperature of the RVL transmitter is 50 °C (122 °F).
- Measure the ambient temperature 5 cm (2 in.) away from all cooling openings.
- Make sure all cooling openings/grids are not obstructed to confirm proper airflow.
- The surrounding air temperature must not exceed the maximum operating ambient temperature of 50 °C (122 °F), especially when mounted in an enclosure.
- The RVL transmitter can be stored in a surrounding air temperature range of -5...+60 °C (23...140 °F).
- The relative humidity (RH) of the ambient air must be 80% noncondensing when the RVL transmitter is operating or being stored.
Required Equipment
To complete the installation of your RVL transmitter, the following components, cables, and tools are required.
Components
• Industrial monitor with integrated RVL receiver or
integrated monitor with external RVL Receiver, 
6300V-RVLDV-RX)
• Industrial PC
• DIN rail (for DIN rail-mount installation only)
• 24V DC (input voltage 18...32V DC) power supply
(1)
The power supply must: (a) satisfy the requirements of a safe extra low voltage (SELV) in accordance with IEC/EN/DIN EN/UL60950-1 and (b) fulfill the requirements NEC Class 2 LPS in accordance with
IEC/EN/DIN EN/UL60950-1. Connect the system with a cable cross-section of 0.75...1.5 mm
(2)
Two cables are required if your installation requires a separate RVL receiver (6300V-RVLDV-RX).
2
Cables
• DVI cable, 11 m (36 ft) maximum length
• USB 2.0 cable, 11 m (36 ft) maximum length
• RVL (Cat. 5E/Cat. 6 A connection) cable, 100 m (328 ft)
maximum length, quantity 1
(1)
2
(from 18...16 AWG) suitable in a minimum of 75 °C (167 °F).
Rockwell Automation Publication 6300V-IN005A-EN-P - November 2022
(2)
For wall mount, shelf mount, or DIN rail attachment:
• Drill and 4 mm drill bit
(2)
• #2 Phillips screwdriver
• M4x20 stainless steel screws, quantity 4
For DC power connector assembly and ground wire installation:
• 2.5 mm hex screwdriver
• Wire stripper, cutter, and crimper tool
• Cutting pliers
• Safety glasses
Tools