Albalá Ingenieros DAD3002C01 Manual

Dual 1 loop-thorough input to 6 outputs aes/ebu digital audio distributor

Advertisement

Quick Links

DAD3002C01
DUAL 1 LOOP-THOROUGH INPUT TO 6 OUTPUTS AES/EBU DIGITAL AUDIO
DISTRIBUTOR
Version 1.0
Albalá Ingenieros, S.A.
23 September 2016 - © Albalá Ingenieros S.A. - All rights reserved
Medea, 4 - 28037 Madrid - Spain

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DAD3002C01 and is the answer not in the manual?

Questions and answers

Summary of Contents for Albalá Ingenieros DAD3002C01

  • Page 1 DAD3002C01 DUAL 1 LOOP-THOROUGH INPUT TO 6 OUTPUTS AES/EBU DIGITAL AUDIO DISTRIBUTOR Version 1.0 Albalá Ingenieros, S.A. 23 September 2016 - © Albalá Ingenieros S.A. - All rights reserved Medea, 4 - 28037 Madrid - Spain...
  • Page 2 DAD3002C01...
  • Page 3: Table Of Contents

    DAD3002C01 DUAL 1 LOOP-THOROUGH INPUT TO 6 OUTPUTS AES/EBU DIGITAL AUDIO DISTRIBUTOR Version 1.0 1. DESCRIPTION ........................5 1.1. The DAD3002C01 ........................... 5 1.2. Features ............................. 6 1.3. Block diagram ..........................7 2. SPECIFICATIONS ......................... 9 3. INSTALLATION ........................11 3.1.
  • Page 4 DAD3002C01...
  • Page 5: Description

    The DAD3002C01 is a TL3000 terminal line module and can be housed in a three rack unit (3 RU) UR3000 mounting frame or a 1 RU UR3100 mounting frame.
  • Page 6: Features

    • Purely linear distributor amplifier. Output signal is a replica of the input signal. • Front panel indicator for input presence. • One UR3000 mounting frame can house up to 12 DAD3002C01 modules. If power supply redundancy is required and FA3000 or FA3001 modules are used then only 10 modules can be housed in the mounting frame.
  • Page 7: Block Diagram

    Albalá Ingenieros | Manual DAD3002C01 1.3. Block diagram...
  • Page 8 Albalá Ingenieros | Manual DAD3002C01 DAD3002C01...
  • Page 9: Specifications

    Albalá Ingenieros | Manual DAD3002C01 2. SPECIFICATIONS AES/EBU digital audio signal input Connector Plug-in terminal, 3.81 mm pitch Impedance Loop-Through or 110 Ω loaded Type Transformer balanced Encoding and electrical characteristics According to EBU Tech. 3250-E/AES3 standard Sampling rate 30 .. 96 kHz...
  • Page 10 Albalá Ingenieros | Manual DAD3002C01 DAD3002C01...
  • Page 11: Installation

    ELECTROSTATIC DISCHARGE. Always use antistatic bags clearly identified with a high degree of shielding for storage and transportation. The DAD3002C01 module is composed of two parts: one DAD3002P01 main board and one XAD3000P02 rear board. Both parts must be installed in a UR3000 or UR3100 mounting frame following the instructions in the corresponding section of this chapter.
  • Page 12: Environmental Considerations

    The attenuation for the loop-through input of the DAD3002C01 is 0.4 dB, equivalent to an amplitude loss of 5%. It is not recommended to cascade more than five modules with loop-through, although this number can be increased.
  • Page 13: Installing The Module In The Mounting Frame

    INSTALLATION section of this manual. 6 - Insert the DAD3002P01 board (main board of the DAD3002C01 module) into the front of the mounting frame. The edges of the card slide into two plastic guides inside the...
  • Page 14: Interconnection

    After these steps, the module is ready to be connected to other equipment. 3.7. Interconnection The following figure shows the DAD3002C01 module rear board connector layout. Rear view of the DAD3002C01 The DAD3002C01 module provides two analog audio inputs with loop-through (IN-A, IN-B) and six outputs (OUT1-A to OUT6-A, OUT1-B a OUT6-B) per section.
  • Page 15: Digital Audio Connections

    For digital audio connections 110 Ω characteristic impedance, two-wire shielded cable is preferred. The GND terminal allows connection of the cable shield. The DAD3002C01 can be used in installations with 75 Ω coax cabling instead of 110 Ω shielded twin-lead cabling.
  • Page 16 Albalá Ingenieros | Manual DAD3002C01 DAD3002C01...
  • Page 17: Operation

    Albalá Ingenieros | Manual DAD3002C01 4. OPERATION This section describes the significance of the front panel indicators of the DAD3002C01 module and their remote control and monitoring ability. 4.1. Front panel description The appearance of the front panel and the elements it contains are shown in the following illustration.
  • Page 18: Functional Description

    1.5 Vpp. 4.2. Functional description The DAD3002C01 distributor does not perform any manipulation of the digital stream - therefore the signal present at the output is a replica of the signal at the input. The distributor accepts AES/EBU digital audio signals with sampling rates between 16 kHz and 96 kHz.
  • Page 19: Glossary

    Albalá Ingenieros | Manual DAD3002C01 5. GLOSSARY AES/EBU This acronym covers the combined AES and EBU standard for transmission of digital audio. The standard defines a serial interface known as AES3 as per AES, EBU 3250-E as per EBU or ITU-R BS.647-2 as per ITU. The interface originally transmitted two channels (one pair) with PCM coding with a bit depth of 20 or 24 bit and a sampling frequency between 32 kHz and 192 kHz.
  • Page 20 Albalá Ingenieros | Manual DAD3002C01 DAD3002C01...
  • Page 21: Regulations

    Albalá Ingenieros | Manual DAD3002C01 6. REGULATIONS AES3 (2003) AES Recommended practice for digital audio engineering - Serial transmission format for two-channel linearly represented digital audio data. See also: EBU Tech. 3250-E, ITU-R BS.647-2 EBU Tech. 3250-E (1992) Specificacion of the digital audio interface.
  • Page 22 Albalá Ingenieros | Manual DAD3002C01 DAD3002C01...
  • Page 23: Versions

    Albalá Ingenieros | Manual DAD3002C01 7. VERSIONS Ver. Date Description 13-06-2013 Preliminary Version 23-09-2016 First version...