• Purely linear distributor amplifier. Output signal is a replica of the input signal. • Front panel indicator for input presence. • One UR3000 mounting frame can house up to 12 DAD3002C01 modules. If power supply redundancy is required and FA3000 or FA3001 modules are used then only 10 modules can be housed in the mounting frame.
Albalá Ingenieros | Manual DAD3002C01 2. SPECIFICATIONS AES/EBU digital audio signal input Connector Plug-in terminal, 3.81 mm pitch Impedance Loop-Through or 110 Ω loaded Type Transformer balanced Encoding and electrical characteristics According to EBU Tech. 3250-E/AES3 standard Sampling rate 30 .. 96 kHz...
ELECTROSTATIC DISCHARGE. Always use antistatic bags clearly identified with a high degree of shielding for storage and transportation. The DAD3002C01 module is composed of two parts: one DAD3002P01 main board and one XAD3000P02 rear board. Both parts must be installed in a UR3000 or UR3100 mounting frame following the instructions in the corresponding section of this chapter.
The attenuation for the loop-through input of the DAD3002C01 is 0.4 dB, equivalent to an amplitude loss of 5%. It is not recommended to cascade more than five modules with loop-through, although this number can be increased.
INSTALLATION section of this manual. 6 - Insert the DAD3002P01 board (main board of the DAD3002C01 module) into the front of the mounting frame. The edges of the card slide into two plastic guides inside the...
After these steps, the module is ready to be connected to other equipment. 3.7. Interconnection The following figure shows the DAD3002C01 module rear board connector layout. Rear view of the DAD3002C01 The DAD3002C01 module provides two analog audio inputs with loop-through (IN-A, IN-B) and six outputs (OUT1-A to OUT6-A, OUT1-B a OUT6-B) per section.
For digital audio connections 110 Ω characteristic impedance, two-wire shielded cable is preferred. The GND terminal allows connection of the cable shield. The DAD3002C01 can be used in installations with 75 Ω coax cabling instead of 110 Ω shielded twin-lead cabling.
Albalá Ingenieros | Manual DAD3002C01 4. OPERATION This section describes the significance of the front panel indicators of the DAD3002C01 module and their remote control and monitoring ability. 4.1. Front panel description The appearance of the front panel and the elements it contains are shown in the following illustration.
1.5 Vpp. 4.2. Functional description The DAD3002C01 distributor does not perform any manipulation of the digital stream - therefore the signal present at the output is a replica of the signal at the input. The distributor accepts AES/EBU digital audio signals with sampling rates between 16 kHz and 96 kHz.
Albalá Ingenieros | Manual DAD3002C01 5. GLOSSARY AES/EBU This acronym covers the combined AES and EBU standard for transmission of digital audio. The standard defines a serial interface known as AES3 as per AES, EBU 3250-E as per EBU or ITU-R BS.647-2 as per ITU. The interface originally transmitted two channels (one pair) with PCM coding with a bit depth of 20 or 24 bit and a sampling frequency between 32 kHz and 192 kHz.
Albalá Ingenieros | Manual DAD3002C01 6. REGULATIONS AES3 (2003) AES Recommended practice for digital audio engineering - Serial transmission format for two-channel linearly represented digital audio data. See also: EBU Tech. 3250-E, ITU-R BS.647-2 EBU Tech. 3250-E (1992) Specificacion of the digital audio interface.