Contents Explanation of the symbols used in this manual ............4 Description ..................5 Field of application of the WS1000 Color control unit ........6 Delivery scope ........................6 Connection and control options ..............7 Automatic functions in overview ..................9 Operation and use of the automatic functions ......
Page 4
Power failure, maintenance works, etc. (restart of control) ......... 60 Installation of the weather station ............... 60 Installation location ......................60 Fitting the holder ......................61 Rear view and drill sketch ....................63 Preparation ........................64 Layout of the circuit board ..................... 65 Adjusting up the DCF77 antenna ...................
Define channel order ..................94 WS1000 Settings ....................95 Settings ......................95 Enter time and date manually ..................95 Change language ......................96 Adjust screen ........................96 Calibrate touch ........................ 97 Enter location (only DCF weather stations) ..............97 Select time zone ......................97 Service settings ....................
Please use this operational guide to adjust the automatic functions to your requirements and enable comfortable manual operation. Delivery scope • WS1000 Color central control and operations unit (with 4, 6, 8 or 10 drive groups) • Weather station •...
Page 9
Motion detector • Smoke detector • Climate sensor (a climate or heating unit which is independent of the WS1000 Color control unit, status query “active”/“not active”, for cancelling ventilation) • Closed-contact for closing notification of a sliding door • Impulse for automatic reset (e.g. button or impulse at alarm activation) The following devices can be connected via a wireless connection: •...
• Additional WGTH-UP indoor sensors (optional) for additional temperature and humidity measurement at various places in the room. This allows various climate areas to be realised (e. g. living and plant areas in the conservatory) • Radio remote control Remo 8 •...
Page 11
Automatic functions for awnings: • Extend according to brightness and the position of the sun or retract regardless of brightness (extending only manually) or extend regardless of brightness (visual protection, automatically retraction only when there is a rain or wind alarm) •...
Page 12
• Close at night/twilight Leave open until • Close daily (settable running times) • Leave open until a selectable indoor temperature is reached (can be switched off) • Leave open until a selectable outdoor temperature is reached (can be switched off) •...
Page 13
• Additionally with roof ventilators WL610 and WL305: recirculating air for heat recovery; recirculating air to avoid condensation • Cancel ventilation when cooling/air-conditioning unit is active If a smoke detector is connected, ventilation will be activated automatically when there is a fire alarm. Automatic functions for light: •...
Operation Weather data display (starting image of the control) As a starting image, the control system shows the current weather data: Sun data Intensity: Light intensity (brightness) in Lux (lx) or Kilolux (klx) Direction: Direction (azimuth) in degrees Height: Elevation over the horizon in degrees Wind The wind speed will be shown in metres per second (m/s) and the windsock changes:...
Page 16
The general weather situation is shown graphically: Sunny or cloudy: The sun moves across the sky according to its current direction and height. Rain: When there is a precipitation report and temperatures above -3 °C, it is raining. Snow: When there is a precipitation report and temperatures below -3 °C, it is snowing.
The touch display Manual control, as well as setting the defaults for the automatic functions and the connected equipment, is via the WS1000 Color’s touch display. The button surfaces are operated in this area by touching the display. When a button is activated, there is visual feedback and a brief audio signal sounds.
Manually operate drives and devices Manual operation of the drives and devices is carried out in the manual menu, which you can reach via the Manual button: Here you can operate all connected drives and devices directly: Use the buttons to select the name of the drive or device you want to operate.
Page 19
Use the arrow keys to scroll through the list. The selected device is marked in white. On the right-hand side you will receive status information (e.g. on/off, open/closed, exhaust air level) and various control options (up/down arrow keys or on/off buttons). For shades and windows, the Down and Up buttons are fitted with automatic time functions.
Internal buttons (group buttons) It is possible to operate several drives or devices at the same time via a collective group button (internal software button). This makes it possible to close all windows with a single button press, for example. These group buttons can be set up in the System menu.
Need help?
Do you have a question about the WS1000 and is the answer not in the manual?