Performance Data Sheets

Culligan Aquasential Tankless RO and Aquasential Tankless RO with Mineral Boost+
Culligan knows the more informed you are about your water treatment systems, the more confident you will be about its performance� It's because
of this and more than seventy years of commitment to customer satisfaction that Culligan is providing this Performance Data Sheet to its customers�
NOTE!
Read this Performance Data Sheet and compare the capabilities of this unit with your actual water treatment needs.
It is recommended that before purchasing a water treatment unit, you have your water supply tested to determine
your actual water treatment needs.
Manufacturer:
Culligan International Company
9399 W� Higgins Rd�, Suite 1100
Rosemont, IL 60018 USA
(847) 430-2800
www�culligan�com
Models:
Culligan Aquasential Tankless RO and Aquasential Tankless RO with Mineral Boost+
These systems must be installed according to local plumbing codes on the cold water line�
This system requires regular replacement of all filters to maintain proper operation� Depending on usage and influent
water quality, the carbon filters should be changed at least annually and the reverse osmosis membrane should be
replaced every 3-5 years� Varying chlorine, sediment, or TDS levels may affect replacement frequency�
Testing Conditions & Results:
Temperature:
77 ± 2°F (25°C)
Pressure:
50 psi (345 kg/cm)
Product Specifications:
Daily Production Rate:
Operating Temp� Range:
Working Press� Range:
Substance Reduction
While testing was performed under standard laboratory conditions, actual performance may vary�
Substance
Concentration
Total Dissolved Solids
This system has been tested and certified by the Water Quality Association according to NSF/ANSI 58 and
CSA B483�1 for the reduction of the substances listed below� The concentration of the indicated substances
in water entering the system was reduced to a concentration less than or equal to the permissible limit for water
leaving the system, as specified by NSF/ANSI 58 and CSA B483�1�
The Aquasential™ Tankless RO and Aquasential Tankless RO with Mineral Booster+ have been tested
and certified by WQA against NSF/ANSI/CAN 372, CSA B483�1 and NSF/ANSI 58 for the reduction of
TDS as verified and substantiated by test data�
CAUTION!
Do not use with water that is microbiologically unsafe or of unknown quality without adequate
disinfection before or after the system. Systems certified for cyst reduction may be used on
disinfected water that may contain filterable cysts.
1
Recovery rating means the percentage of the influent water to the membrane portion of the system that is available to the user
as reverse osmosis treated water when the system is operated without a storage tank or when the storage tank is bypassed�
This system has been tested and shown to operate at its calculated recovery rating under standard laboratory conditions�
This reverse osmosis system contains a replaceable component critical to the efficiency of the system� Replacement of the
reverse osmosis component should be with one of identical specifications, as defined by the manufacturer, to assure the same
efficiency and contaminant reduction performance�
Refer to your Installation and Operating Instructions and written limited Warranties for more specific product information� To avoid
contamination from improper handling and installation, your system should only be installed and serviced by your Culligan dealer�
Performance will vary based on local water conditions� The substances reduced by these systems are not necessarily in your water�
² Efficiency rating means the percentage of the influent water to the system
that is available to the user as reverse osmosis treated water under
operating conditions that approximate typical daily usage�
13
01044539 A 12/22
pH:
Turbidity: <1 NTU
715 gpd
Recovery Rating¹:
40-100°F (5–38°C)
Electrical Requirements:
15–120 psi (1–11 kg/cm
2
)
Efficiency Rated
Influent Challenge Water
Concentration (mg/L)
750 ± 40
7�5 ± 0�5
58�4%
120VAC, 50/60 Hz, 1 Amp
2
:
65�2%
Max. Permissible Water
Concentration (mg/L):
187
Average Percent
Reduction
81�4%