Error Code / Fault Display / Signal - Siemens SN97YX01CI User Manual

Table of Contents

Advertisement

Fault
Appliance door opens too
wide when activated.

Error code / Fault display / Signal

Fault
E:2130 lights up.
E:2060 lights up.
E:3000 lights up.
E:3100 lights up.
E:3400 lights up.
E:3200 or indicator for wa-
ter supply lights up.
1
Depending on the appliance specifications
Cause
Door is not correctly adjus-
ted.
Cause
Intake opening of Zeolith
container is covered by
items of tableware.
Appliance has detected cal-
cified heating element.
Water protection system is
activated.
Water protection system is
activated.
Water is continuously run-
ning into the appliance.
Supply hose is kinked.
Water tap is turned off.
Water tap is jammed or
furred up.
The filters in the water con-
nection of the supply or
AquaStop hose are blocked.
Troubleshooting en
Troubleshooting
Adjust the appliance door as de-
scribed in the installation instruc-
tions.
Troubleshooting
Re-arrange the tableware in the ap-
pliance so the "Intake opening of
the Zeolith container " → Page 15
is no longer obstructed.
Descale the appliance.
1.
Operate the appliance with the wa-
2.
ter softening system.
Turn off the water tap.
1.
Call "Customer Service"
2.
→ Page 61.
Turn off the water tap.
1.
Call "Customer Service"
2.
→ Page 61.
Turn off the water tap.
1.
Call "Customer Service"
2.
→ Page 61.
Install the supply hose without
kinks.
Turn on the water tap.
Turn on the water tap.
The flow rate must be at least 10 l/
min when the water supply is open.
Switch off the appliance.
1.
Pull out the mains plug.
2.
Turn off the water tap.
3.
Unscrew the water connection.
4.
1
47

Advertisement

Table of Contents
loading