Xiamen Comfort Science &Technology GROUP Co., Ltd
10:Disassembly of the remote controller
A:Disconnect the vibration wire and the air pipe of the seat pad, then
take off the seat pad.
B:Take off the five screws and then take away the panel.
The seat panel has been take off
C:Cut the cable ties which fasten the remote controller wire to the frame.
D:Disconnect the connecter then we can take off the remote controller.
The remote controller
11:Disassembly of the inflator pump
A:Refer to Maintenance of backrest to take off the backrest.
B:Take off the 6pcs screws of the main PCB cover, then pull the PCB cover,
then take it off.
C:Take off four screws which fixing the tie of the inflator Pump.
中国·厦门蒙发利科技集团有限公司
The seat pad has been
take away