Advertisement
Measuring range: | 0 - 300 mm/12" |
Resolution: | 0,01 mm, 0.0005" |
max. error: | ± 0,02 mm |
max. operational speed: | ± 1,5 m/sec. |
Repeatability: | ± 0,01mm |
Power supply: | Battery SR44W (1,55 V) |
Storag temperature: | 5°C bis 40°C |
Humidity influence: | 0 - 80% |
Open battery-cover to the down side. Replace battery, with anode outside. Now close the battery-cover very carefully.
Trouble | Cause | Correction way |
No display |
|
|
LCD does not count |
Fault in electronic |
Put battery out and replace after 30 sec. or take new battery |
Display flashing |
Voltage too low | Replace battery |
Description | Remark | |
Preparing | Open fixing screw, clean the measuring faces and switch the caliper on | |
Origin resetting | Keep measuring faces to contact and press (ZERO) key | You can reset the caliper at any position |
MM/INCH conversion | Press (inch/mm) key to be in METRIC or in INCH system condition |
NOTES:
Please prepare with measuring very carefully. Keep surfaces clean. The caliper should be regulary cleaned with cotton-cloth. Do not use petrol. Do not expose the caliper direct to the sun light, ultraviolet rays or extreme temperatures.
Prevent it from any shock and do not immerse the caliper in any liquid.
Electric etching or engraving by high voltage can destroy the electronic chip, no guarantee will be given!
Never dismantle the caliper housing. The battery should be taken out, if no use for a long time.
Do not give used batteries in refuse. Please give it to a special collecting depot.
CE - declaration of conformity:
This product complies with the 89/336/EEC.
The declaration of conformity is made according to the following norms EN 61326-1:1997 and A1:1998.
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.