Beta 1654DGT - Electronic Digital Caliper Instructions For Use

Beta 1654DGT - Electronic Digital Caliper Instructions For Use

Advertisement

Beta 1654DGT - Electronic Digital Caliper Instructions For Use

Function

Function

  1. ON/OFF
  2. Origin resetting
  3. Battery-cover
  4. Display
  5. Fixing screw
  6. Metric / Inch conversion
  7. Fine adjustment

Specifications

Measuring range: 0 - 300 mm/12"
Resolution: 0,01 mm, 0.0005"
max. error: ± 0,02 mm
max. operational speed: ± 1,5 m/sec.
Repeatability: ± 0,01mm
Power supply: Battery SR44W (1,55 V)
Storag temperature: 5°C bis 40°C
Humidity influence: 0 - 80%

Battery - replacement

Open battery-cover to the down side. Replace battery, with anode outside. Now close the battery-cover very carefully.

Trouble shooting

Trouble Cause Correction way

No display

  1. Voltage too low
  2. Battery has no contact
  1. Replace battery
  2. Clean contacts

LCD does not count

Fault in electronic Put battery out and replace after 30 sec.
or take new battery

Display flashing

Voltage too low Replace battery

Function

Description Remark
Preparing Open fixing screw, clean the measuring faces and switch the caliper on
Origin resetting Keep measuring faces to contact and press (ZERO) key You can reset the caliper at any position
MM/INCH conversion Press (inch/mm) key to be in METRIC or in INCH system condition

NOTES:
Please prepare with measuring very carefully. Keep surfaces clean. The caliper should be regulary cleaned with cotton-cloth. Do not use petrol. Do not expose the caliper direct to the sun light, ultraviolet rays or extreme temperatures.

Prevent it from any shock and do not immerse the caliper in any liquid.

Electric etching or engraving by high voltage can destroy the electronic chip, no guarantee will be given!

Never dismantle the caliper housing. The battery should be taken out, if no use for a long time.

Do not give used batteries in refuse. Please give it to a special collecting depot.

CE - declaration of conformity:
This product complies with the 89/336/EEC.

The declaration of conformity is made according to the following norms EN 61326-1:1997 and A1:1998.

Documents / Resources

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Download Beta 1654DGT - Electronic Digital Caliper Instructions For Use

Advertisement

Need help?

Need help?

Do you have a question about the 1654DGT and is the answer not in the manual?

Questions and answers

Table of Contents