Page 1
EPC Series People Counting System for Community Health and Social Distance Protection Warranty Certificate & User Manual www.edselectronic.com...
Display Messages and Definitions Section 3 Assembly and Wiring Section 4 Setting Up the System Section 5 Panel User Settings Section 6 Maintenance Section 7 Technical Drawings Section 8 Technical Specifications Section 9 Recycling Section 10 Warranty Certificate EPC Series User’s Manual...
Page 4
However, the total liability of EDS shall not exceed the sales price of the product in all cases.
Page 5
Where optional wall mounting is not possible, the mounting bracket to be attached to the beam detector Screwing or adhesive option is available for the beam detector A second beam detector is required in areas with different entrance and exit EPC Series User’s Manual Section 1: Introduction...
Page 6
Product Family Description PENBAR-50 Beam Detector, 2 IR LED, 50cm PENBAR-100 Beam Detector, 4 IR LED, 100cm EPCP People Counter Control Panel EPCS People Counter Audible Warning EPCV People Counter Visual Warning EPC Series User’s Manual Section 1: Introduction...
Illuminates when the battery is on. Alarm Lights when there is an alarm in one or more zones in the system. Audible Warning Yellow Illuminates if audible warning is disabled. EPC Series User’s Manual Section 2: Display Messages and Definitions...
Page 8
1 and above Left Exiting menu and confirmation key Arrow Right Entering menu key Arrow Navigation in menu key, goes up Arrow Down Navigation in menu key, goes down Arrow EPC Series User’s Manual Section 2: Display Messages and Definitions...
Page 9
In the event of an error, the fault description appears on the screen. These are battery low, AC error, penbar open circuit, penbar short circuit and obstacle fault respectively. Battery Low Appears on the screen when the battery voltage is lower than 11V. EPC Series User’s Manual Section 2: Display Messages and Definitions...
Page 10
IMPORTANT: The number of beam detector appears with the fault message. Please check monitoring section to see date and time of the error. Obstacle This message appears when there is obstacle in beam detector front for a long time. EPC Series User’s Manual Section 2: Display Messages and Definitions...
The beam detector, audible and visual warning device supply should be connected to the 12V DC control panel. 4x0.22 coded screened cable should be used for the connection distance between 0-100 meters. EPC Series User’s Manual Section 3: Assembly and Wiring...
Page 12
Screw Dowel M4 x 30 (4X) Ø 6 mm (4X) Mounting Points Fuse Battery Location Air Duct Battery Thermistor Electrical Connections Fuse Connection Supply Fuse - 500mA Grid Line Earth Neutral EPC Series User’s Manual Section 3: Assembly and Wiring...
Page 13
If the same door will be used as entrance and exit, it should be mounted at a distance of 25cm between the beam detectors. (Figure 2). 25cm 60-100cm Figure 1 Figure 2 EPC Series User’s Manual Section 3: Assembly and Wiring...
Page 14
The maximum distance between the columns are 6 meters. Never exceed this distance. IMPORTANT: Install the product as shown in the drawing so that it is not affected by sunlight. Beam Detector Connection Beam detectors facing each other. Rx� Tx� Tx� Rx� EPC Series User’s Manual Section 3: Assembly and Wiring...
Page 15
You can mount the device on the wall with M4X40 YSB sheet metal screw and dowel from the mounting points shown. After the electrical connections are completed, close the top cover and fix it with the screw on the bottom and top side. EPC Series User’s Manual Section 3: Assembly and Wiring...
Page 16
The Power LED lights up, the date and time displays are displayed on the LCD screen. Please go to the settings section to adjust date and time. EPC Series User’s Manual Section 3: Assembly and Wiring...
Page 17
Products to be used EPCP People Counter Control Panel 1 Piece PENBAR Beam Detector 2 Pieces EPCS People Counter Audible Warning 1 Piece EPCV People Counter Visual Warning 1 Piece DOOR 1 EPC Series User’s Manual Section 3: Assembly and Wiring...
Page 18
People Counter Control Panel 1 Piece PENBAR Beam Detector 2 Pieces EPCS People Counter Audible Warning 1 Piece EPCV People Counter Visual Warning 1 Piece Entrance Exit DOOR 1 DOOR 2 EPC Series User’s Manual Section 3: Assembly and Wiring...
Page 19
Products to be used EPCP People Counter Control Panel 1 Piece PENBAR Beam Detector 4 Pieces EPCS People Counter Audible Warning 2 Pieces EPCV People Counter Visual Warning 2 Pieces DOOR 1 DOOR 2 EPC Series User’s Manual Section 3: Assembly and Wiring...
Page 20
People Counting System EPC Series EPC Series User’s Manual Section 3: Assembly and Wiring...
Page 21
PENBAR Beam Detector 4 Pieces EPCS People Counter Audible Warning 2 Pieces EPCV People Counter Visual Warning 2 Pieces Entrance Entrance DOOR 1 DOOR 2 Exit Exit DOOR 3 DOOR 4 EPC Series User’s Manual Section 3: Assembly and Wiring...
Page 22
Pink +12V DC Pink Brown Exit +12V DC Gray Direction White Brown Door 2-Entrance 2. Penbar Pink +12V DC Pink Brown Enterence +12V DC Gray Direction White Brown Beam Detector Connections EPC Series User’s Manual Section 3: Assembly and Wiring...
Date and Time arrangement User Code Authority level 2, change password Authority Code Authority level 3 change password Version Version information Fabrication Turn back to fabrication settings Test To test the control panel EPC Series User’s Manual Section 4: Setting Up the System...
Page 24
The system section is reached with the down button. Pressing the right > button enters the system section. Single or double selection is made with up and down buttons. Confirm with left < button. EPC Series User’s Manual Section 5: Panel Settings...
Page 25
< button. Access Level 2: Factory 22 encrypted user code, in addition to access level 1, can reset, start / stop audible warning, disable relays and test. EPC Series User’s Manual Section 5: Panel Settings...
Page 26
RS-232 connection allows to recieve information of the total capacity, real-time number of people in the area, number of people entering and leaving the area. User Access Levels Staff Officer Executive Maintenance Technician / Engineer EPC Series User’s Manual Section 5: Panel Settings...
Note: Do not move and disassemble the device. Never move the transparent material. If you encounter a problem with the device, contact an authorized service. EPC Series User’s Manual Section 6: Maintenance...
Page 28
People Counting System EPC Series Section 7: Technical Drawing People Counting Control Panel Beam Detector 1000 People Counting People Counting Audible Warning Device Visual Warning Device EPC Series User’s Manual Section 7: Technical Drawing...
The first 2 digits of the serial number on the product is indicating the production date Year of production (The number on the label of the product). EDS Elektronik Destek Sanayi ve Ticaret Ltd. Meclis Mah. Teraziler Cad. Hayran Sk. No: 4 34785 Manufacture Sancaktepe / İstanbul / Turkey...
Page 30
The first 2 digits of the serial number on the product is indicating the production date Year of production (The number on the label of the product). EDS Elektronik Destek Sanayi ve Ticaret Ltd. Meclis Mah. Teraziler Cad. Hayran Sk. No: 4 34785 Manufacture Sancaktepe / İstanbul / Turkey...
Page 31
The first 2 digits of the serial number on the product is indicating the production date Year of production (The number on the label of the product). EDS Elektronik Destek Sanayi ve Ticaret Ltd. Meclis Mah. Teraziler Cad. Hayran Sk. No: 4 34785 Manufacture Sancaktepe / İstanbul / Turkey...
Page 32
The first 2 digits of the serial number on the product is indicating the production date Year of production (The number on the label of the product). EDS Elektronik Destek Sanayi ve Ticaret Ltd. Meclis Mah. Teraziler Cad. Hayran Sk. No: 4 34785 Manufacture Sancaktepe / İstanbul / Turkey...
Page 33
When your device has reached the end of its useful life, contact your local authority for disposal and recycling options, take it to a collection point for the recycling of electrical and electronic equipment, or hand it over to EDS Elektronik. This product does not contain harmful or prohibited substances specified in the Regulation on the Control of Waste Electrical and Electronic Equipment issued by the Turkish Republic Ministry of Environment and Urbanization.
EPC Series User’s Manual Section 10: Warranty Certificate...
Page 35
7. For the problems to be arisen regarding the Warranty Certificate, you can apply to the Directorate-General of Consumer Protection and Market Surveillance of the Ministry of Customs and Trade. Manufacturer title / Service address: EDS Elektronik Destek San. ve Tic. Ltd. Şti. Meclis Mah. Teraziler Cad. Hayran Sok. No:4 34785 Sancaktepe/İstanbul/Turkey Tel: 0216 528 45 00 Fax: 0216 314 17 80 e-mail: eds@eds.com.tr www.eds.com.tr...
Page 36
06.20.V1 Technical specifications are subject to change without prior notice. EDS Elektronik Destek San. Ve Tic. Ltd. Şti. Meclis Mah. Teraziler Cad. Hayran Sok. No:4 34785 Sancaktepe / İstanbul / Turkey +90 216 528 45 00 eds@eds.com.tr www.eds.com.tr...
Need help?
Do you have a question about the EPC Series and is the answer not in the manual?
Questions and answers