SLM-010 Salt Level Monitor EDSPN: 2062103001 Revision History The Table below displays revision history for the chapters in this User Guide Date Version Change Made April 04, Original release 2023 May 07, 30% alarm indication and message added 2024 Contact Us For the most up-to-date information about Electronic Design Service products, go to Electronic Design Service website at www.eldesignservice.com.
EDSPN: 2062103001 About SLM-010 Salt Level Monitor SLM-010 is a Bluetooth Low Energy Salt Level Monitor. SLM-010 provides water softener salt level data and operational status information. This device communicates with a smartphone or a tablet, which indicates salt level, operational status and audible alarm. Alarm is activated when water softener salt level dropped below 40% and 30%.
SLM-010 Salt Level Monitor EDSPN: 2062103001 1. Inside Box SLM-010 device with UART cable connected. SJ-GU-TF-Luna A01 LiDAR Module. 3. 120VAC / +5VDC Power adapter (with cable). 4. Two screws for LiDAR module installation. 5. Pair of Hanging Strips for SLM device installation Note: SLM-010 Serial Number is located on enclosure backside.
SLM-010 Salt Level Monitor EDSPN: 2062103001 Connection SLM-010 device, Luna LiDAR module and power connections is shown in Figure 3. SWI3-5-N-MUB 120VAC / +5VDC Power Adapter Micro USB SJ-GU-TF-Luna A01 UART Cable (TF-Luna Cable) Figure 3 Connection Diagram See installation instruction in Installation and Adjustment section.
SLM-010 Salt Level Monitor EDSPN: 2062103001 Installation and Adjustment Luna LiDAR module and SLM-010 needs to be installed on water softener salt tank cover. The following tools are required for installation: 1. Phillips screwdriver 2. Power Drill with 1/2 in bit 3.
(3” diameter) does not have any obstacles (see Figure 2). 3. Drill ½” Cable Hole in marked position. 4. Connect power cable and install SLM-010 on external side of salt tank lid (near Cable Hole) as it is shown in Figure 4 by using pair of hanging strips.
SLM-010 Salt Level Monitor EDSPN: 2062103001 SLM-010 iOS Application Installation and Operation Installation Install SLM-010 Application on iPhone or iPAD from App store. Before starting the application: Enable background refresh for iPhone SLM-010 application: >Settings>Salt Level Monitor>Background App Refresh Enable Notification for iPhone SLM-010 application: >Settings>Salt Level Monitor>Notifications>Allow Notifications/Sounds/Badges Enable Contacts for iPhone SLM-010 application: >Settings>Salt Level Monitor>Contacts...
Page 13
1. Allow Bluetooth - (if it was not done before start) 2. Allow Notifications - (if it was not done before start) 3. Allow access to contact list (application uses SLM-010 contact to read message phone and salt tank height only) - (if it was not done before start) Note: Restart application again after all access has been allowed.
SLM-010 Salt Level Monitor EDSPN: 2062103001 iOS Application Screenshot The Figure 9 shows screenshot of SLM-010 Application. Figure 9 iOS Application Screenshot Application receives data steadily from device if RSSB is more than -92dBm. The location of device shall guaranty that RSSB more than -92dBm for continuous operation. However, if your iPhone (or iPAD)
Connect power adapter to your 110v wall outlet. A front LED will start blinking with 1.5sec Intervals. This indicates normal operation. Start SLM-010 application on iPhone or iPAD. These are the following operation conditions: Normal Operation (status id “NORMAL” and Salt level is more than 40%):...
(the “Warranty Period”). During the warranty period, SLM- 010 will be repaired or replaced at no cost to you. EDS will inspect and diagnose the failure, at which point we will determine whether root cause of this failure is due to defective materials or workmanship.
6 minutes. Bluetooth will not connect: a) Assuming the iOS device is withing Bluetooth range of the SLM-010. Use “Forget This Device” function in iOS device Setting > Bluetooth>SumpSaltMonitorV010> Forget This Device and turn off and turn on power of SLM-010 device.