Rs232 Communication Commands - Gentec PA70W User Manual

40 watt power amplifier
Table of Contents

Advertisement

4.3.5 RS232 Communication Commands

Communication Protocol: RS232 Communication Protocol
Baud rate: 9600
Command
1A1.
Switching the audio to input 1
2A1.
Switching the audio to input 2
3A1.
Switching the audio to input 3
0A0.
Mute Audio of MIC and Line out
1A0.
Mute audio of MIC
2A0.
Mute audio of line out
3A0.
Enable noise gate.
4A0.
Disable noise gate.
0A1.
Unmute Audio
600%
Checking the working status
601%
MIC volume up
602%
MIC volume down
603%
Line volume up
604%
Line volume down
605%
Bass level up
606%
Bass level down
607%
Treble level up
608%
Treble level down
609%
Initialization, back to the default setting
610%
Enable/disable the ducking function.
Preset the volume level of ducking
4[x][x]%
function. [xx] arranges from [00] to [60].
61 degrees in total.
Preset MIC volume, [xx] arranges from
5[x][x]%
[00] to [60]. 61 degrees in total.
Preset line volume, [xx] arranges from
7[x][x]%
[00] to [60]. 61 degrees in total.
Preset the bass level, [xx] arranges from
8[x][x]%
[00] to [08]. 9 degrees in total.
Preset the treble level, [xx] arranges from
9[x][x]%
[00] to [08]. 9 degrees in total.
40W Power Amplifier
Data bit: 8
Stop bit: 1
Function Description
Parity bit: none
12
Feedback Code
A: 1 -> 1
A: 2 -> 1
A: 3 -> 1
Mute
Mute MIC
Mute LIN
Gate On
Gate Off
Unmute Audio
A: 1 -> 1
Volume of MIC : 50
Volume of LINE : 50
Bass of LINE : 4
Treble of LINE : 4
Ducking Off
Volume of MIC: 51
Volume of MIC: 51
Volume of LINE: 51
Volume of LINE: 51
Bass of LINE: 4
Bass of LINE: 4
Treble of LINE: 4
Treble of LINE: 4
Init OK
Ducking off/Ducking on
Ducking of LINE: 50
Volume of MIC: 50
Volume of LINE: 50
Bass of LINE: 4
Treble of LINE: 4