WARNING
TO AVOID SERIOUS PERSONAL INJURY OR DEATH
FROM ELECTROCUTION, DISCONNECT ELECTRIC
POWER BEFORE MANUALLY MOVING LIMIT NUTS.
MAKE SURE THE LIMIT NUTS ARE POSITIONED BETWEEN THE LIMIT SWITCH ACTUATORS BEFORE
PROCEEDING WITH ADJUSTMENTS.
1. Depress open limit switch. The operator should stop.
2. To increase door travel, spin nut away from actuator. To decrease door travel, spin limit nut toward actuator.
3. Adjust open limit nut so that door will stop in open position with the bottom of the door even with top of door
opening.
4. Repeat Steps 1 and 2 for close cycle. Be sure close limit actuator is engaged as door fully seats at the floor.
If other problems persist, call our toll-free number for assistance - 1-800-528-6563.
ADJUST LIMITS
Press Travel Nut Retainer Down
Toward Frame TO DISENGAGE.
Open Limit
Nut
OPEN
OLS
Actuator
Open Limit
Switch
6
Close Limit
Travel Nut
Nut
Retainer
CLOSE
SLS
CLS
Close Limit
Switch