Troubleshooting - Woods L6008 Installation Manual

Motion-activated fixture
Table of Contents

Advertisement

Available languages

Available languages

Troubleshooting

Symptoms
Lights are not coming
on at all
Cannot get the TEST
mode working
Motion sensor triggers
with motion but stays on
Motion sensor comes on
randomly, or blinks in
test mode
Not enough or too much
detection range
Possible Cause
1.No power connection
2.Wrong wiring
3.Faulty bulbs
The sensor is NOT in the
default setting condition.
from surrounding objects
to the sensor
2. A light bulb is too close
to the Sensor creating heat
3. Installed in moving,
busy area
2.Motion sensor aiming
issue
1.Motion sensor
RANGE setting
Solution
1. Make sure both the circuit breaker
and wall switch are in the ON position
2. Check the wiring to make sure all
the connections are correct
and secure
3.Make sure the bulbs are not
damaged and have good connection
with the bulb socket
1.Need to RESET the sensor, method #1
• Push the TIMER touchpad key to
move the LED to the OFF position.
• Then push the TIME touchpad key to
move the LED to the TEST position
• Sensor RESET is done and continue to
Or, RESET the sensor to the default,
method #2
• Turn the wall power switch OFF.
• Press the TIME, SENS and Timer touch-
pad keys at the same time for about 2
seconds.
• Turn the wall power switch back ON.
lights turn ON
lights turn OFF
• The sensor is RESET to its default TEST
mode.
1. Reposition the motion sensor
2. Adjust the light bulb position
away from Motion Sensor
3. Move the Motion Sensor away from
busy areas such as sidewalks or
passing cars
1. Reposition the bulbs away from
Motion Sensor
2. Do not aim at heating/cooling
ducts, pools of water, windows, or
smooth walls
1. Adjust the Motion Sensor's
sensitivity to desired RANGE level
7