Summary of Contents for Laird MRC 150

  • Page 1 Doc#: 60-70-004 Revision: 07 MRC 150/300 Thermoelectric Re-circulating Liquid Chiller User’s Manual USA: +1 888.246.9050 Europe: +44.1342.315044 Asia: +886.3.312.9292 Website: www.lairdtech.com • Email: clv.customerpos@lairdtech.com...
  • Page 2: Table Of Contents

    Laird Technologies chiller. Incoming Inspection Laird Technologies’ chiller units are designed, built, and packaged to withstand the shock and vibration normally associated with shipment by common carriers. Occasionally, improper handling during shipment, such as excessive vibration, crushing, etc., will cause damage to the product.
  • Page 3: Product Handling

    (10.4 to 104) Controller accuracy, °C ± 0.16 Frequency, Hz 50/60 For ambient conditions outside this range, please contact Laird Technologies. For temperature settings below 2°C, an appropriate coolant must be used. USA: +1 888.246.9050 Europe: +44.1342.315044 Asia: +886.3.312.9292 www.lairdtech.com • clv.customerpos@lairdtech.com...
  • Page 4 Doc#: 60-70-004 Revision: 07 User’s Manual Page 4 Chiller model MRC 150 MRC 300 Cooling capacity, Watt 149 (508) 290 (990) (BTU/hr) Current, Amperes, 4.7 (2.4) 8.5 (4.3) 115VAC (230VAC) Input power, Watts Fluid capacity, mL (oz.) 250 (8.4) 450 (15.2) Dimensions, h×w×d,...
  • Page 5 Doc#: 60-70-004 Revision: 07 User’s Manual Page 5 MRC 150 Performance Charts Therma l Capacity ∆ T = Outlet Fluid Temperat ure - Ambient Temperature Capacity (BTU/hour) Capac ity (Watts) USA: +1 888.246.9050 Europe: +44.1342.315044 Asia: +886.3.312.9292 www.lairdtech.com • clv.customerpos@lairdtech.com...
  • Page 6 Doc#: 60-70-004 Revision: 07 User’s Manual Page 6 MRC 300 Performance Charts Thermal Capacity ∆T = Outlet Fluid Temperature - Ambient Temperature Capacity (BTU/hour) 1000 1200 Capacity (Watts) USA: +1 888.246.9050 Europe: +44.1342.315044 Asia: +886.3.312.9292 www.lairdtech.com • clv.customerpos@lairdtech.com...
  • Page 7 Doc#: 60-70-004 Revision: 07 User’s Manual Page 7 USA: +1 888.246.9050 Europe: +44.1342.315044 Asia: +886.3.312.9292 www.lairdtech.com • clv.customerpos@lairdtech.com...
  • Page 8: Installation And Operation Instructions

    Page 8 Installation and Operation Instructions 1. Install Laird Technologies chiller on a level surface capable of supporting the weight of the Unit. Allow 30 cm (12”) clearance around the air inlet and discharge areas to insure proper air circulation. If obstacles block the airflow, the unit may overheat.
  • Page 9: Recommended Fluid Couplings

    Doc#: 60-70-004 Revision: 07 User’s Manual Page 9 Recommended Fluid Couplings For the fluid line connections, Laird Technologies recommends the following male couplings. CPC (Colder Products Co.) Unit Tubing Inner Diameter Part Number 1/4” PLCD26004 MRC 150, 5/16” PLCD26005 MRC 300 3/8”...
  • Page 10 Doc#: 60-70-004 Revision: 07 User’s Manual Page 10 Factory Available range Function Code Unit Recommended range setting of values °C or Set Point 10° -200°C to 400°C -15°C to 40°C °F Set Scale Max °C or (High Set Point H i . S c 40°C 400°C 40°C...
  • Page 11: Troubleshooting Guide

    Doc#: 60-70-004 Revision: 07 User’s Manual Page 11 Troubleshooting Guide Problem Possible Reason Corrective Action Unit will not start, with power switch turned ON. Controller Check Power supply and ensure Power not applied. display is off and fans are not proper voltage in the line.
  • Page 12: Serviceability

    This warranty covers repair or replacement of product, to be done at a Laird Technologies facility, for a period of one (1) year from date of shipment. Customer is responsible for shipping product to Laird Technologies freight prepaid. Laird Technologies in turn will return the warranted product to customer freight prepaid, if within the time period specified above.
  • Page 13: Return Procedure

    Laird Technologies will in no way be liable for incidental or consequential damage whatsoever or for any other claims by the customer for damages in connection with Laird Technologies products, even if advised in advance of the possibility of such damage.