Mobi Technologies 700027 User Manual

Mobi Technologies 700027 User Manual

Smart bluetooth ear arm blood pressure monitor

Advertisement

Quick Links

Smart Bluetooth Ear Arm
Blood Pressure Monitor
700027 User Manual
Version: V2.1
Revision Date: 7/18/22

Advertisement

Table of Contents
loading

Summary of Contents for Mobi Technologies 700027

  • Page 1 Smart Bluetooth Ear Arm Blood Pressure Monitor 700027 User Manual Version: V2.1 Revision Date: 7/18/22...
  • Page 2 Product Composition The product is comprised of the host machine and the cuff of Electronic Blood Pressure Monitor. Application Scope The Electronic Blood Pressure Monitor is used to measure the diastolic pressure, systolic pressure, and pulse rate of adults by oscillometric method for diagnostic reference.
  • Page 3: Safety Precautions

    Safety Precautions The warnings and illustrations shown in the User Manual enable you to use the product safely and correctly, thus preventing you and others from being injured, specifically as follows: Legend, mark and meaning Warning message Applied Apart of Type BF (The applied part is the anti-electric shock) Compliance with WEEE Standard Refer to Operating Instructions...
  • Page 4 Quick Start Guide Avoid smoking, eating, drinking caffeinated drinks, or exercising for 30 minutes before taking measurement. 1. Sit upright in a chair with both feet on the floor. 2. Remove tight fitting clothing from your upper arm along with any thick clothing.
  • Page 5 Overview Monitor Features Universal Cuff  Irregular Heartbeat Detector  99 Readings * 2 Users  Bluetooth Transmission Function  Auto-off Power Saving Feature  Operated by 4 AA batteries (USB 5V optional)  - 4 -...
  • Page 6: Packing List

    Display Packing List Name Quantity Smart Bluetooth Ear Arm Blood Pressure Monitor Cuff Dry Battery (AA) User Manual Zipped Carrying Bag - 5 -...
  • Page 7 Preparation 2.1 Battery Installation a) Open the battery cover as shown in the picture. b)Place 4 AA dry batteries. Pay attention to the battery electrode indication. 2.2 Battery power indication and replacement After the product is turned on, if low power symbol appears on the screen, the measurement cannot be performed, and the battery must be replaced.
  • Page 8 2.4 Cuff The applicable arm circumference range of the cuff is 22-36cm or 22-42cm. Connection: Insert the air plug of cuff air tube into air jack of the Electronic Blood Pressure Monitor. Figure shown as above: - 7 -...
  • Page 9: Function Setting Mode

    Function Setting Mode 3.1 User mode Switch between “User 1” and “User 2” can be processed in the “OFF” state or upon the measurement completion, by short press on the “User ” button. 3.2 Year/Month/Date/Time setting In the “OFF” state, enter the setting mode by long press on the “User ”...
  • Page 10 After entering the “Date” setting mode, 1/01 will flash on the screen. Press the “Memory ” button, and the value will be incremented among 01 and 31. Press the “User ” button for “Date” value confirmation and enter the “Time” setting mode. After entering the “Time”...
  • Page 11 value of the sector will start from the minimum individually. 3.3 Talking function setting (voice version only) After entering talking function setting mode, “ ” will show up at the SYS area, with the current voice status “ ” / “ ”...
  • Page 12: Correct Method Of Use

    Correct Method of Use 4.1 How to use the cuff (1) Place the cuff flat on the table, leave the hook & loop downwards, and pass the end of cuff through the metal ring to form a loop. The hook &...
  • Page 13 4.2 Starting measurement Power on state, after you wear the cuff correctly, the “cuff detection icon” lights up, then you can start the measurement: (1) Press the “Power ” button, and the device will return to zero automatically, the air pump will start to inflate the cuff, and the screen will display the change of the pressure in the cuff.
  • Page 14 symbol and start flashing. The flashing “heart” symbol will be displayed on the screen. (4) Upon measurement completion, the measured values of systolic pressure, diastolic pressure and pulse will be displayed on the screen. (5) The screen will continue to display the measurement results unless your long press on the “Power ”...
  • Page 15 users by pressing the “Memory ” button for 3 seconds. 4.5 Use Bluetooth function See the Quick-Start guide for setup. 4.6 Classification standard for blood pressure condition There is no definition of hypotension yet. Generally, if the systolic blood pressure is less than 100mmHg (13.3kPa), it is hypotension. - 14...
  • Page 16 Contraindications, Precautions, Warnings and Prompt Instruction (1) Warning: Keep the device out of the reach of the children under 12 and people who can’t express their intention. When children of 12~18 use the device, they should be accompanied by the adults. Pregnant women shall use under the guidance of doctors.
  • Page 17 measurement results is very dangerous. (2) Precautions: Do not repair, disassemble, or modify the Electronic Blood Pressure Monitor without permission. Do not collide or drop the host to avoid collision or strong impact on the device. Do not mix old and new batteries of different brands for use. Indoor temperature, environment, noise, user's body position, speech or exercise might affect the blood pressure measurements.
  • Page 18: Troubleshooting

    Troubleshooting * If you have trouble using the device, please check the following instruction. Problem Possible cause How to correct Replace new batteries or use Low battery the USB for power supply. No display when press the The polarities of Install the batteries in correct Power button batteries are...
  • Page 19 Please check if the cuff The cuff is twined wearing is correct and follow too loose. Section 4.1 How to use the “Err 4” cuff. displayed The air bag of cuff Replace with a new cuff. is ruptured. The air tube is Please check if the air tube is detected to be “Err 5”...
  • Page 20: Storage And Maintenance

    Storage & Maintenance Keep the device away from direct sunlight, extreme temperatures,  humidity, or moisture. Use a dry, soft cloth to clean the device, or if desired, use a cloth  lightly dampened with water. Do not use corrosive cleaner, benzene, thinner or other volatile ...
  • Page 21: Specifications

    Specifications Product Name Electronic Blood Pressure Monitor Model JPD-HA121 Display Mode Digital display mode Measuring Mode Oscillographic method Measuring Body Part Upper arm 0-295mmHg Pressure value Measuring Range (0kPa-39.3kPa) Pulse value 40-199 pulse beats/min Pressure value ±3mmHg(±0.4kPa) Static measurement accuracy Pulse value ±...
  • Page 22 138.5mm (length) *120mm (width) * 63.2mm Monitor Size (height) Screen Size 83mm (length) *97mm (width) Upper-arm-type cuff Cuff (Measured arm circumference 22-36cm or 22-42cm) Cuff, User Manual, Dry battery, Zipped Carrying Annexure High-performance dry battery can be used for Battery Life about 300 times at normal temperature Service Life 5 years...
  • Page 23 Avoid strong impact, direct impact, exposure, or rain during transportation. The packaged Blood Pressure Monitor shall be stored indoors at the Transportation and temperature of -20℃~55℃ and the relative Storage Environment humidity of 10%~93%, atmospheric Condition: 70kPa-106k, without corrosive gas and with good ventilation.
  • Page 24 Questions? Please visit: www.getmobi.com Support portal: https://mobisupport.zendesk.com Support ticket: https://www.getmobi.com/gethelp For detailed instructional manual please follow this link: https://www.getmobi.com/user-manuals © 2022 MOBI Technologies, Inc. All Rights Reserved - 23...

Table of Contents