Page 1
Braemar, Inc. ER910, ER910, 920 ER910, ER910, ER910, ER910, ER910, ER910, 920 920 AF Arrhythmia Event Monitor Caution: U.S. Federal law restricts this device to sale by or on the order of a physician.
Page 2
The stated express warranties are in lieu of all obligations of liabilities on the part of Braemar for damages, including but not limited to, special indirect or consequential, arising out of or in connection with the use or performance of Braemar products.
Event recording is activated by the patient or by automatic Indications for Use ..................2 event detection. The ER910 (1 channel) and ER920 (2 channel) event monitors provide Precautions....................2 up to 30 minutes of total recording time and will operate as a simple looping event recorder for a minimum of 30 days with two AAA Monitor Components ................3...
Setup Steps Monitor Components This manual is designed to allow a technician to follow the instructions page by page to setup the ER910/920 and ER910/920 AF Monitor. Here is the general layout: Connect leads and electrodes to patient. Prepare Monitor for recording.
ER910/920 and ER910/920 AF Event Monitor ER910/920 and ER910/920 AF Event Monitor Monitor Preparation 1 and 2 Channel (4 Lead) Electrode Placement General setup: Remove the Patient Cable if it is connected to the Monitor. Open the battery compartment by sliding battery door This is a typical electrode placement.
Page 6
ER910/920 and ER910/920 AF Event Monitor ER910/920 and ER910/920 AF Event Monitor General notes: Notes about sound: A. Lead loss sound overrides the POST-EVENT SOUND A. To leave the programming mode without saving your changes, remove the batteries. setting. B. If you enter the programming mode, events stored in B.
Page 7
ER910/920 and ER910/920 AF Event Monitor ER910/920 and ER910/920 AF Event Monitor Choose program: User Defined options continued Choose either the DEFAULT or CUSTOM option. The DEFAULT Display Option Description option only allows you to change the Contrast of the display. The...
Page 8
ER910/920 and ER910/920 AF Event Monitor ER910/920 and ER910/920 AF Event Monitor Connect the patient: User Defined options continued A. At this time, the patient leads should be connected to the Display Option Description electrodes and the electrodes should be connected to the patient.
ER910/920 and ER910/920 AF Event Monitor ER910/920 and ER910/920 AF Event Monitor Patient Operating Instructions To Record: Events to be recorded will be described by the physician. Press the RECORD/SEND button for two seconds until an audible The Monitor should be ready when you receive it from the technician. If tone is heard, then release.
ER910/920 and ER910/920 AF Event Monitor ER910/920 and ER910/920 AF Event Monitor To Send: Remove the Patient Cable from the Monitor. Troubleshooting (page 1 of 2) Set the Monitor on a flat surface with the speaker hole up. Symptom Recommended Solution Call the receiving center.
ER910/920 and ER910/920 AF Event Monitor ER910/920 and ER910/920 AF Event Monitor Event Markings Troubleshooting (page 2 of 2) The following shows typical event markings that are generated by the No information received by Make sure mouthpiece of phone is directly over Monitor Monitor and appear on the receiving station strip chart.
ER910/920 and ER910/920 AF Event Monitor ER910/920 and ER910/920 AF Event Monitor Service and Maintenance Cleaning Equipment Symbols Remove the batteries before cleaning the recorder. Clean the battery Symbol Description terminals with a soft dry cloth. Dampen a soft cloth with mild detergent and water to clean the recorder, lead wires, and belt clip.
ER910/920 and ER910/920 AF Event Monitor ER910/920 and ER910/920 AF Event Monitor Specifications Additional equipment classification information as required in EN 60601-1 Functional A. EQUIPMENT not suitable for use in the presence of a ER910 1 channel only FLAMMABLE ANAESTHETIC MIXTURE WITH AIR of WITH...
ER910/920 and ER910/920 AF Event Monitor ER910/920 and ER910/920 AF Event Monitor Electromagnetic Emissions Electromagnetic Emissions test Compliance environment - guidance RF emissions Group 1 The ER9xx uses RF energy only CISPR 11 for its internal function. Therefore, its RF emissions are very low and...
ER910/920 and ER910/920 AF Event Monitor ER910/920 and ER910/920 AF Event Monitor Recommended Separation Distances Refer to the following table for recommended separation distances between the ER9xx and portable and mobile RF communications equipment. The ER9xx is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled.
Page 16
Braemar Inc. Phone: 800.328.2719 1285 Corporate Center Drive, Suite 150 Fax: 651.286.8630 Eagan, MN 55121 USA E-Mail: Service@BraemarInc.com Copyright 2006, Braemar Inc. All rights reserved...