NA300 Series Programmable Logic Controller Technical Specifications and User Manual
provided by the encoder. The upper limit is 31.
The status bit is a status flag that is refreshed when this bit is received in the
sequence. For some encoders, this bit can indicate errors detected in the data frame.
Parity bit can be declared in the frame via the parity parameter . If a parity bit is
selected, the module performs a parity check based on the selected parity type (even
or odd).
The baud rate parameter has four choices that affect the maximum cable length:
Baud rate
Maximum
Cable Length
Terminal Wiring Definition
100kHz
200kHz
350m
500kHz
180m
- 92 -
1MHz
70m
20m