Duplomatic EPC 10 Series Manual

Duplomatic EPC 10 Series Manual

Electronic control unit for open loop single solenoid proportional valve

Advertisement

Quick Links

FUNCTIONAL BLOCK DIAGRAM
BROWN
WHITE
GREEN
YELLOW
SPECIFICATIONS
Power supply
Required power
Output current
standard
Reference signal
optional
Input reference signal
impedance
Electrical connection
Electromagnetic compatibility (EMC)
- EMISSIONS
EN 50081-1
- IMMUNITY
EN 50082-2
(see par. 4 - note 1)
Protection to atmospheric
agents (according to IEC 144
standard)
Operating temperature range
Mass
89 110/101 ED
÷
10
30
VCC
Ripple included
W
see par. 2.1
A
see par. 1 and 5
0
÷
+10
V
0
÷
+5
100
kΩ
DIN 43650
in compliance with
89/336 EEC
IP 67
÷
°C
-20
+70
kg
0,20
ELECTRONIC CONTROL UNIT
PROPORTIONAL VALVE
PLUG VERSION
P2 - RAMP
Ramp regulation
P1 - GAIN
Scale factor
regulation
89 110/101 ED
EPC
FOR OPEN LOOP
SINGLE SOLENOID
SERIES 10
P4 - SWITCHING
PWM frequency
regulation
P3 - OFFSET
Offset current
regulation
1/4

Advertisement

loading
Need help?

Need help?

Do you have a question about the EPC 10 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Duplomatic EPC 10 Series

  • Page 1 89 110/101 ED ELECTRONIC CONTROL UNIT FOR OPEN LOOP SINGLE SOLENOID PROPORTIONAL VALVE SERIES 10 PLUG VERSION FUNCTIONAL BLOCK DIAGRAM BROWN P4 - SWITCHING WHITE PWM frequency regulation GREEN P2 - RAMP Ramp regulation YELLOW SPECIFICATIONS ÷ Power supply Ripple included Required power see par.
  • Page 2 SERIES 10 1 - IDENTIFICATION CODE E P C - 1 / 10 ÷ E0 = reference signal 0 +10V (standard) Power amplifier E2 = reference signal 0 ÷ DIN 43650 electrical connection Series No. (from 10 to 19 sizes and mounting dimensions remain unchanged) For single solenoid proportional valves Switching frequency:...
  • Page 3 SERIES 10 3.3 - P3 - OFFSET (Offset current regulation) 5 - DEFAULT CONDITIONS Potentiometer “P3” enables regulation of the offset current of the The electronic control unit is supplied factory-set. valve. This is used to eliminate the valve insensivity zone (dead zone). Standard settings are: The offset current is activated when the reference signal exceeds ADJUSTMENTS...
  • Page 4 GREEN 8 - OVERALL AND MOUNTING DIMENSIONS dimensions in mm CABLE DUPLOMATIC OLEODINAMICA SpA 20025 LEGNANO (MI) - P.le Bozzi, 1 / Via Edison Tel. 0331/472111-472236 - Fax 0331/548328 89 110/101 ED REPRODUCTION IS FORBIDDEN. THE COMPANY RESERVES THE RIGHT TO APPLY ANY MODIFICATIONS.