InMax-..-.F1

Technical data

Torque motor
Torque spring return (F)
Dimension of external torque
Supply voltage/Frequency
Dimension
Protection class
Angle of rotation and indication
Working direction
Motor running time
Motor running time 3 Sec.
Motor
Spring return (F)
Spring return running time (F)
Safety operations
Response time spring return
Control mode
Thermal circuit
InPro-TT-.. connection
Integrated aux. switches
Axle of the actuator
Electrical connection
Diameter of cable
Cable gland
Manual override
Integral heater
Housing material
Dimensions
Weight
Ambients
Operation mode at
runningtime motor 3 sec
Operation mode at
runningtime motor 15 sec
Self adjustment
Maintenance
Wiring diagrams (SB)
Delivery
Parameter at delivery
Certification
InMax actuators size S
EMV
Directive 2004/108/EC
Low voltage
Directive 2006/95/EC
IP-Protection
IP66, in acc. with EN 60529
Potential compensation
external PA-terminal, 4 mm²
Schischek GmbH Germany, Mühlsteig 45, Gewerbegebiet Süd 5, 90579 Langenzenn, Tel. +49 (0)9101 9081-0, Fax +49 (0)9101 9081-77, E-Mail info-de@schischek.com
InMax-8-.F1
8 Nm
min. 8 Nm
minimum 2 Nm lower load reduce lifetime
24...240 VAC/DC, ± 10% , self adaptable, Frequency 50...60 Hz ± 20 %
max. starting currents see table "EL-S" (in acc. with voltage, I
class I (grounded)
95°, incl. ~ 5° pre-tention, mechanical value indication
selectable by left/ right mounting to the damper /valve shaft
3 / 15 / 30 / 60 / 120 sec. at 90° selectable on site
due to external torque and supply voltage 3 to 4 Sec at 90° ancle
brushless DC Motor
spring return in the event of loss of power
spring return in < 1 sec. at 90°
min. 1.000 in acc. with construction of damper and ambient, consider minimum load
up to 1 sec. after power failure
On-off
Additional circuit to connect a passive potential free thermostat as a safety sensor, e.g. type InPro-TT-.. in version ..-BF1
direct to the actuator with M12 × 1,5 mm fast connection
2 aux. switches, switching at 5° and 85° Angle of rotation in types ..-SF1 and ..-BF1
double squared 12 × 12 mm, direct coupling, 100 % overload protected
cable, ~1 m, diameter of wires 0,5 mm²
~ Ø 7,3...9,6 mm acc. to type
M16 × 1,5 mm standard
manual override only if supply voltage is cut, use delivered socket wrench, slow motion, enough torque/ force is required
Attention: with manual operation of actuators with spring return danger of injury exists, with release/let go the allen key.
integral heater, controlled, for ambient temperature down to -40°C
aluminium die cast housing, painted (optional in stainless steel version AISI 316 Type InMax-...-VAS, amercoat painting type InMax ...-CTS)
L × W × H = 210 × 95 × 80 mm, for diagramm see extra information "ME-S"
~ 3,5 kg Aluminium housing (stainless steel ~ 7 kg)
storage temp. -40...+70°C, working temperature -40...+50°C, humidity in acc. with EN 60335-1
the motor will work in 3 seconds only after 1 minute voltage supply. While open/close-operation (open voltage supply and shut it down)
the motor works only with speed 15 sec./90°
at 15/30/60/120 sec. 100 % ED
if you select 3 sec. and 15 sec. mode for motor you need to start the self adjustment mode
maintenance free, maintenance must be complied with regional standards, rules and regulations
SB 1.4 / 1.5 / 7.5 / 7.6
1 actuator, 1 m cable, double squared shaft connection 12 × 12 mm, 4 screws M4 × 100, 4 nuts M4, socket wrench for simple manual override
8 Nm, 30 sec./90°
www.schischek.com

E X P L O S I O N P R O O F

InMax-15-.F1
15 Nm
min. 15 Nm
minimum 5 Nm lower load reduce lifetime
>> I
), max. 20 W blocking position, approx. 16 W for heater
start
rated
SB 1.4 / 1.5 / 7.5 / 7.6
15 Nm, 30 sec./90°
Accessories or special solutions size S
...-VAS
above listed types in stainless steel housing AISI 316, parts nickel-plated
...-CTS
above listed types in Al-housing with amercoat painting, parts nickel-plated
InBox-...
Terminal boxes
InSwitch
2 external aux. switches, adjustable
MKK-S
mounting bracket for terminal boxes type InBox-... direct on actuator
HV-S
comfortable manual override for InMax actuators size S
Adaptations various adaptations for dampers/ valves on request
BFH-S
mounting holder for actuators at fire danger area
InPro-TT-..
passive temperature sensor
AR-12-xx
reduction of square damper connection from 12 mm to 11, 10, ...