Alemite 9979-A Service Manual

Alemite 9979-A Service Manual

High-pressure stationary pump

Advertisement

Description

The major components of the high-pressure
stationary pump assembly model 9979-A consist of a(n):
• air-operated motor
• double-acting reciprocating pump tube
• cover assembly

• follower plate

Pump Assembly

The high-pressure (50:1 ratio) pump included with
the assembly is designed to deliver a range of greases
directly from a 400-pound container.
Follower Plate
The follower plate is designed with a flexible edge
that allows operation in tapered containers.

Specifications

IMPORTANT: For detailed information on
the pump tube (including specifications
and performance data) refer to SER 9930.
For information on the motor, please refer
to SER 339413.
This document contains confidential information that is the property of Alemite Corporation
670797
and is not to be copied, used, or disclosed to others without express written permission.
Service Guide
High-Pressure Stationary Pump
Alemite Corporation
PO Box 473515, Charlotte, North Carolina 28247-3515
www.alemite.com
©
Copyright
Weight
Container
lbs
400-pound
50
Figure 1 High-Pressure Stationary Pump
2000 by Alemite Corporation
9979-A
Width x Height
kg
Inches
22.7
24 x 43-1/2
Model 9979-A
SER 9979-A
Revision (4-02)
Cm
61 x 110.5

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 9979-A and is the answer not in the manual?

Questions and answers

Summary of Contents for Alemite 9979-A

  • Page 1 PO Box 473515, Charlotte, North Carolina 28247-3515 www.alemite.com © Copyright 2000 by Alemite Corporation SER 9979-A This document contains confidential information that is the property of Alemite Corporation 670797 Revision (4-02) and is not to be copied, used, or disclosed to others without express written permission.
  • Page 2 172207-1 77786 Screw, 1/4 " -20 x 1/2 " 338165 338911 Plate, Follower 338911 Legend: Part numbers left blank (or in italics) are not available separately Figure 2 High-Pressure Stationary Pump Model 9979-A - Exploded View Revision (4-02) Alemite Corporation...
  • Page 3 High-Pressure Stationary Pump SER 9979-A Assembly Follower Plate 3. Place Follower Plate (6) onto the top of the product. • With a wobbling motion, eliminate any air that may NOTE: Refer to Figure 2 for component be trapped underneath the Follower Plate. Force the identification on all assembly procedures.
  • Page 4 SER 9979-A High-Pressure Stationary Pump Revision (4-02f) Alemite Corporation...

Table of Contents