Table of Contents

Advertisement

Available languages

Available languages

Quick Links

Description
The major components of these stripped pump models consist
of an air-operated motor and a pump tube. The air motor connects
directly to the single-acting reciprocating pump tube.
These high-pressure stripped pumps (50:1 ratio) are designed
to deliver a range of greases [up to NLGI # 2] and operate directly
from their original drums or bulk containers.
Each pump model is designed with a pump tube length to
accommodate different size containers. See Figure 1.
Specifications
Air Motor
Piston Diameter x Stroke
Inches
Centimeters
3 x 3-5/16
7.6 x 8.4
For details on the air motor, refer to Service Guide SER 339413
Pump Tube
Max. Material
Pressure
Material
Outlet
psi
Bars
3/8 " NPTF
7500
517
* For detailed information, refer to Figure 3
Table 1 High-Pressure Stripped Pump Specifications
Package Models
The usage for each model of stripped pump is indicated below.
Pump
Package Model
Model
9911
9911-H, 9911-Z
9911-R
9911-A, 9911-B
Table 2 High-Pressure Stripped Pump Usage
This document contains confidential information that is the property of Alemite Corporation
670785
and is not to be copied, used, or disclosed to others without express written permission.
Service Guide
High-Pressure Stripped Pump
Maximum Air
Pressure
Air Inlet
psi
1/4 " NPTF (f)
150
Delivery/Minute
Displacement
(Approximate)*
per Cycle
3
Pounds
Kilograms
In
3
1.4
0.39
Pump
Package Model
Model
9950
9950-A, -HC, 9951, -S, -T
9950-B
9911-HA
9950-C
9911-HB
Alemite Corporation
PO Box 473515, Charlotte, North Carolina 28247-3515
www.alemite.com
©
Copyright
2000 by Alemite Corporation
Bars
10.3
3
Cm
6.39
Container Size
Stripped
Pump Model
lbs
9911
35
9911-R
70
9950
120
9950-B
-
9950-C
-
9950-D
400
Figure 1 High-Pressure Stripped Pump
Models 9911, 9950 Series
9911, 9911-R
9950, 9950-B
9950-C, 9950-D
X
Y
kg
Inches
Cm
Inches
-
13.75
34.9
23.6
-
17.68
44.9
27.53
50
27.75
70.5
37.6
12.5
15.50
39.4
25.35
20
19.00
48.3
28.85
180
37.06
94.1
46.91 119
SER 9911/9950
Revision (4-00)
Cm
59.9
69.9
95.4
64.3
73.2

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 9911 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Alemite 9911

  • Page 1 PO Box 473515, Charlotte, North Carolina 28247-3515 www.alemite.com © Copyright 2000 by Alemite Corporation SER 9911/9950 This document contains confidential information that is the property of Alemite Corporation 670785 Revision (4-00) and is not to be copied, used, or disclosed to others without express written permission.
  • Page 2 SER 9911/9950 High-Pressure Stripped Pump Figure 2 High-Pressure Stripped Pump Models 9911, 9950 Series - Exploded View Revision (4-00) Alemite Corporation...
  • Page 3 High-Pressure Stripped Pump SER 9911/9950 Item Numeric Order Part No. Description Notes Part # (Item #) Motor Assembly, Air See SER 339413 14536 Bolt, Carriage, 1/4 " -20 x 7-1/2 " X171000-7 Included w/ Nut, Serrated Flange, 1/4 " -20...
  • Page 4: Preventive Maintenance

    SER 9911/9950 High-Pressure Stripped Pump Accessories Part Number Description 326750-F1 Bung Adapter, 2 " NPTF (m) Table 3 High-Pressure Stripped Pump Accessory Component Preventive Maintenance Refer to section entitled Overhaul for the procedures necessary to perform maintenance. Daily Weekly Monthly...
  • Page 5 High-Pressure Stripped Pump SER 9911/9950 Alemite Corporation Revision (4-00)
  • Page 6 SER 9911/9950 High-Pressure Stripped Pump Overhaul 3. With a side-to-side motion, pull the Air Motor Assembly from the Body. NOTE: Refer to Figure 2 for component 4. Remove Keepers (12) from the Body. identification on all overhaul procedures. 5. Remove the bottom end cap from the Body.
  • Page 7: Clean And Inspect

    High-Pressure Stripped Pump SER 9911/9950 7. Inspect the corners of Stop (22) for breakage. Place 18. Remove Guide (19) from the Primer Rod. the Stop into the bottom of Tube (21). Make sure the 19. Remove Roll Pin (17) that secures Upper Rod (16) to Stop is secure within the Tube when pressure is the Extension as required.
  • Page 8 SER 9911/9950 High-Pressure Stripped Pump 9. Install Roll Pin (17). • Use a small hammer. 10. Install the Rod assembly [chamfer end first] into the bottom of the Body. • Use care passing the Seal. 11. Install and seat Gasket (10) into the Body.
  • Page 9 High-Pressure Stripped Pump SER 9911/9950 Air Piston CAUTION CAUTION Do not overtighten Flange Nuts (1b). Component damage can occur. Use care not to switch Washers (3 and 7). Com- ponent damage can occur. 32. Torque the Flange Nuts in a crisscross pattern from 60 to 70 inch-pounds (6.8 - 7.9 Nm).
  • Page 10: Installation

    SER 9911/9950 High-Pressure Stripped Pump Installation If the pump does not stall, refer to the Troubleshooting Chart for details. Additional items that should be incorporated into the 1. Check the motor for air leakage. air piping system are listed in Table 6.
  • Page 11: Guide D'entretien

    © Copyright 2000, Alemite Corporation SER 9911/9950 Ce document contient des informations confidentielles qui sont la propriété de Alemite Corporation 670785 Révision (4-00) et qui ne peuvent être copiées, utilisées ou divulguées à des tiers sans accord écrit exprès.
  • Page 12 SER 9911/9950 Pompe exposée haute pression Illustration 2 Pompe exposée haute pression modèles 9911, 9950 - vue éclatée Révision (4-00) Alemite Corporation...
  • Page 13 Pompe exposée haute pression SER 9911/9950 Ordre numérique N° de Référence Description Qté Remarques Référence pièce (n° de pièce) Assemblage du moteur à air Voir SER 339413 14536 Boulon de carrosserie, 1/4" -20 x 7-1/2" 4 X171000-7 Inclus avec Écrou à collet dentelé, 1/4" -20...
  • Page 14: Entretien Préventif

    SER 9911/9950 Pompe exposée haute pression Accessoires Référence Description 326750-F1 Adaptateur de bonde, NPTF 2" (m) Tableau 3 Composant accessoire des pompes exposées haute pression Entretien préventif Reportez-vous à la section intitulée Inspection pour connaître les procédures d’entretien requises. Tous les jours...
  • Page 15 Pompe exposée haute pression SER 9911/9950 Alemite Corporation Révision (4-00)
  • Page 16 SER 9911/9950 Pompe exposée haute pression 3. Retirez l’ensemble du moteur à air du corps dans un Inspection mouvement latéral. REMARQUE : reportez-vous à 4. Retirez les armatures (12) du corps. l’illustration 2 pour identifier les 5. Retirez l’embout inférieur du corps.
  • Page 17: Nettoyage Et Inspection

    Pompe exposée haute pression SER 9911/9950 6. Remplissez l’assemblage du clapet antiretour (11) 18. Retirez le guide (19) de la tige de l’amorceur. de solvant. Vérifiez qu’il n’y a aucune fuite. 19. Retirez la goupille élastique (17) qui fixe la tige supérieure 7.
  • Page 18 SER 9911/9950 Pompe exposée haute pression IMPORTANT : ne desserrez pas la tige de l’amorceur de plus d’un demi-tour. 8. Dévissez la tige de l’amorceur jusqu’à ce que le trou de la tige de l’amorceur soit aligné sur le trou de l’extension.
  • Page 19 Pompe exposée haute pression SER 9911/9950 Piston à air 31. Fixez l’assemblage du moteur à air sur le corps du tube de pompe avec les armatures (12), les boulons de carrosserie ATTENTION et les écrous à collet. Veillez à ne pas inverser les rondelles (3 et 7), ATTENTION faute de quoi les composants risquent d’être...
  • Page 20 SER 9911/9950 Pompe exposée haute pression Installation Si la pompe ne s’arrête pas, reportez-vous au tableau de dépannage pour plus de détails. Les autres pièces qui doivent être intégrées au système de canalisations d’air sont répertoriées dans le tableau 6.

This manual is also suitable for:

9911-r99509950-b9950-c9950-d

Table of Contents