Troubleshooting; Electrical Wiring - Buffalo Heavy Duty Meat Mincer 12 Instruction Manual

Table of Contents

Advertisement

EN

Troubleshooting

A qualified technician should carry out repairs if required.
Fault
The unit is not working
Minced meat does not exit
the appliance evenly

Electrical Wiring

This appliance is supplied with a 3 pin BS1363 plug and lead.
The plug is to be connected to a suitable mains socket.
This appliance is wired as follows:
Live wire (coloured brown) to terminal marked L
Neutral wire (coloured blue) to terminal marked N
Earth wire (coloured green/yellow) to terminal marked E
This appliance must be earthed.
If in doubt consult a qualified electrician.
Electrical isolation points must be kept clear of any obstructions. In the event of any emergency
disconnection being required they must be readily accessible.
Compliance
The WEEE logo on this product or its documentation indicates that the product must
not be disposed of as household waste. To help prevent possible harm to human
health and/or the environment, the product must be disposed of in an approved and
environmentally safe recycling process. For further information on how to dispose of
this product correctly, contact the product supplier, or the local authority responsible for
waste disposal in your area.
BUFFALO parts have undergone strict product testing in order to comply
with regulatory standards and specifications set by international,
independent, and federal authorities.
BUFFALO products have been approved to carry the following symbol:
All rights reserved. No part of these instructions may be produced or transmitted in any form or by any means, electronic,
mechanical, photocopying, recording or otherwise, without the prior written permission of BUFFALO.
Every effort is made to ensure all details are correct at the time of going to press, however, BUFFALO reserves the right to
6
CH134_EN_A5_v1_20220407.indb 6
CH134_EN_A5_v1_20220407.indb 6
Probable Cause
Unit not switched on
Plug or lead is damaged
Fuse in the plug has blown
Mains power supply fault
Overload protection has
activated
Barrel cap is on too tight
Cutting plate is blocked
Cutting blade is blunt
change specifications without notice.
Telephone Helpline: 0845 146 2887
Solution
Check the unit is plugged in correctly and
switched on
Replace plug or lead
Replace the fuse
Check mains power supply
Reset the appliance (Page 4)
Loosen the cap
Remove and clean the plate
Replace the cutting blade
2022/4/7 14:24
2022/4/7 14:24

Advertisement

Table of Contents
loading

This manual is also suitable for:

Heavy duty meat mincer 22Ch133Ch133-eCh134Ch134-e

Table of Contents