Systems Specifications; Operating Specifications; Feed Water Parameters; Design Test Conditions - Reo-Pure LP3 Series Installation Operation & Maintenance

Hide thumbs Also See for LP3 Series:
Table of Contents

Advertisement

SYSTEM SPECIFICATIONS
Low Feed Water Pressure Switch:
Product Water Pressure Switch:
*System production may vary depending upon incoming water temperature and chemistry.
Systems are designed for use with potable water sources only
Inlet Feed Water Pressure:
Max Operating Pressure:
Operating
Inlet
Pressure
Conn.
150 PSI
3/8" NPTF
Shipping Dimensions
Wgt
Height
Width
Lbs
In
Cm
In
75
41
104
21

OPERATING SPECIFICATIONS

Production Rates:
500 GPD (1,893 LPD)*
Minimum 95% – Maximum 99%
Rejection Rate:
System shuts down at 15 PSI decreasing pressure
System shuts down at 45 PSI ~ System starts at 25 PSI
Standard – 120V, 60Hz, 1Ph (Optional – 220V, 50Hz, 1Ph)
Electrical:
150 PSI
Operating Pressure:

FEED WATER PARAMETERS

Hardness:
Maximum 10 GPG (Over 10 GPG should be softened)
Iron:
Maximum 0.01 PPM (Dissolved Only)
Turbidity:
Maximum 1 NTU
Hydrogen Sulfide:
Must be removed
Chlorine:
Maximum 0.1 PPM
Minimum 40 PSI Maximum 85 PSI
4 to 10
pH Range:
Feed Water TDS:
Consult Reo-Pure Manufacturer if TDS exceeds 2,000 PPM
Minimum 45
Temperature:
180 PSI

DESIGN TEST CONDITIONS

150 PSI
Operating Pressure:
Feed Water TDS:
500 PPM as NaCI
o
Design Temperature:
77
F (25
TFC Polyamide – 21" High Flux
Membrane Element:
Design Recovery:
50%

DESIGN SPECIFICATIONS

Product &
Filter
Reject Conn.
Housing
3/8" Tube
20" SL
WEIGHT AND DIMENSIONS
Depth
Cm
In
Cm
53
19
48
o
F – Maximum 90
o
F
o
C)
Membrane
Motor
Element
60 Hz
2 x 26"
1/4 HP
60 GPH
Installation Dimensions
Height
Width
In
Cm
In
Cm
33
84
14
36
LP3-500 Owner's Manual | 4
Pump
Depth
In
Cm
16
41

Advertisement