tams elektronik GBM-8.2 Manual page 9

Track occupancy indicator 8-fold
Table of Contents

Advertisement

tams elektronik
Connecting the track sections
The busy status can only be reported trouble free, if one conductor is isolated at both ends of
each section to be monitored:
3-rail systems: centre conductor or both rails
2-rail systems (analogue): "-" rail
2-rail systems (digital): one of the two rails
Please note that, due to the principle, in analogue 2-rail systems (DC systems) only vehicles
are detected that enter the track section in the direction marked as "direction of travel" in the
connection diagram.
GBM-8.2
G1, G2, G3, ... G8
V1
Monitoring of switched-off track sections
Track sections that are to be switched off during operation (e.g. in a staging yard) can also be
monitored with the GBM-8.2. For this purpose, a resistor with a value < 1.5 kW must be
installed in the supply line to the track section concerned in such a way that it bridges the
switch in the switched-off state.
3.2.
Connection to
isolated conductors in the track sections
uninterrupted conductor
GBM-8.2
Connections GBM-8.2 | 9