Needle

Vertical
feed front
arm

Feed dog



Feed base arm

16) Adjust so that the needle is aligned with the center
of the needle hole in the feed dog.
Adjust so that the needle enters the center of the
needle hole in the feed dog. (B=B')
Condition: Needle bar is at its lower dead point;
the feed amount is 0 mm
[Lateral position]
Move feed lever base  to adjust its lateral posi-
tion. Then, tighten feed lever base setscrew  .
Where necessary, loosen clamping screw  of the
feed base arm and clamping screw  of the ver-
tical feed front arm to adjust the lateral position of
the feed base.
At this time, check to make sure that feed lever 
does not come in contact with feed lever support ❾ .
[Longitudinal position]
Move the feed base arm to adjust its longitudinal
position. Then, tighten the clamping screw  of the
feed base arm.
17) Adjusting the height of the feed dog
Condition: Feed dog is at its highest position;
the feed amount is 0 mm.
Turn the handwheel to bring the feed dog to its
highest position.
Loosen clamping screw  of the vertical feed front
arm.
Turn the vertical feed front arm to adjust the feed
dog height to 0.6 to 0.7 mm above the top surface
of the throat plate. Then, tighten clamping screw  .