Installation
11. Installation
11.1 Installation environment
The product is not intended for continuous exposure to direct sunlight. There is a risk that the product
might be overheating.
The product is not intended for installation in contact with corrosive chemical compounds. Check the
resistance of the front panel film to a specific compound before installation.
Do not use tools of any kind (screwdrivers, etc.) to operate the touchscreen of the product.
IP67 is guaranteed only if:
• An appropriate cable (JSCAxxxx) is used. The cables JSCAU001, JSCAU002, JSCAU003 and
JSCAU004 can be orderd as accessories.
• The max. deviation from the plane surface to the cutout is ≤0.5mm.
• The thickness of the case where the product is mounted is from 1.5mm to 3mm.
• The max. surface roughness where the gasket is applied is ≤120μm.
11.2 Installation procedure
For details on installation, please refer to the "Installation Guide" provided with the product.
Notice
Tightening torque: 1000Ncm (nut),130Ncm (screws)
18
D
Cable
Max. 3mm
JSCAxxxx (IP67)
Max. 10mm
Standard Ethernet
ACGM0198V3EN Version 3.0