MC0322 through MC2148
Air, Water, and Remote Cooled Service Manual
Performance Data
Ice production (lb /24 hr @ 90/70)
Ice production (lb /24 hr @ 70/50)
Water use, gallons ice only
Ice weight / cycle (lb)
Refrigerant charge, oz R-404A
Fan pressure cut out / cut in, PSIG
High pressure cut out / cut in, PSIG
Compressor Amps, beg. - end, freeze
Compressor Amps, harvest
Cycle Time (minutes) @ 70/50
Cycle Time (minutes) @ 90/70
Beginning Freeze - Low Side Pressures @ 70/50
Ending Freeze - Low Side Pressures @ 70/50
Beginning Harvest - Low Side Pressures @ 70/50
Ending Harvest - Low Side Pressures @ 70/50
Beginning Freeze - Low Side Pressures @ 90/70
Ending Freeze - Low Side Pressures @ 90/70
Beginning Harvest - Low Side Pressures @ 90/70
Ending Harvest - Low Side Pressures @ 90/70
Number of Evaporators
Evaporator Height in Inches
Headmaster Set point
Average heat load for air conditioning unit sizing
BTUH
Water use, water cooled condenser only
Water Cooled Condenser GPM @ 45 oF temp
OPR valve setting PSIG at compressor dome
CPR valve setting PSIG at compressor dome
Compressor Amps, beg. - end, freeze - 3 Phase
MC0322A
MC0322W
255
329
356
366
48
61
2.4-2.6
2.4-2.6
14
11
190/240
7.3-4.8
7.3-4.8
6.2
6.2
9-10
8-10
12-13
10-11
50
56
26
32
100
95
105
105
60
57
32
32
130
110
125
130
1
1
6
6
5200
5200
454
0.2
January 2022
Page 71
MC0522A
MC0522W
340
409
475
480
69
90
4.8-5.2
4.8-5.2
17
14
190 /240
500 / 300
400/300
7.8 -6.0
7.4-5.8
7.8
6.8
14-17
14-16
22
17
57
50
30
31
80
81
98
95
67
55
33
31
85
100
110
110
1
1
12
12
7900
7900
701
0.3
MC0722A
566
770
106
7.3-7.5
20
190-240
500/390
5.8-4.1
4.2
16
20
60
25
87
84
62
29
100
94
1
18
12750