Prodigy Cuber System Information - Scotsman Prodigy Elite MC0322 Service Manual

Air, water, and remote cooled modular cuber
Table of Contents

Advertisement

MC0322 through MC2148
Air, Water, and Remote Cooled Service Manual

Prodigy Cuber System Information

Overall System Type:
• Refrigeration: Mechanical, either air cooled, water cooled or remote cooled.
• Water System: Inlet water solenoid valve fills reservoir once per cycle. Purge solenoid valve opens to
discharge some reservoir water once per cycle.
• Control System: Electronic
• Harvest cycle sensor: Conductivity probe
• Water full/empty sensor: Conductivity probe
• Bin Control: Curtain Switch
• Ice type: Unified
• Harvest system: Hot gas defrost with mechanical assist
Electrical Components:
• Compressor
• Contactor
• Water Pump
• Inlet Water Solenoid Valve
• Purge or purge Valve
• Fan Motor(s)
• Fan motor pressure control
• High pressure cut out – certain AC models only
• Harvest Assist Solenoid(s)
• Hot Gas Valve(s)
• Controller
• Transformer – 12v AC for the controller only
• Water Level Sensor
• Ice Thickness Sensor
• Curtain Switch(es)
January 2022