SleepSense Operation
LOGIC ( SleepSense)
●
At First the Unit will operate at Cooling mode for 20 minutes at setting condition.
●
With the motion sensor, the room air conditioner can monitor human movement. If no human movement is
detected, then the temperature will increase ( in case of cooling operation ) automatically and unit
continues running for 1 hour.
The Fan speed will be changed to one tap lower than the set fan speed.
●
If the condition of activity in the room is stable then the unit will continue running with the temperature
increased by another 1°C( in case of cooling) respectively.
●
During the SleepSense operation , if Big activity /movement is detected, the temperature and Fan speed
will resume back to previous setting.
●
During the SleepSense operation , if small activity /movement is detected, the temperature will decreased
( in case of cooling) and Fan speed will increase by one tapping.
- 15 -