SleepSense Operation
LOGIC ( SleepSense)
At First the Unit will operate at Cooling mode for 20 minutes at setting condition.
With the motion sensor, the room air conditioner can monitor human movement. If no human movement is
detected, then the temperature will increase ( in case of cooling operation ) automatically and unit
continues running for 1 hour.
The Fan speed will be changed to one tap lower than the set fan speed.
If the condition of activity in the room is stable then the unit will continue running with the temperature
increased by another 1°C( in case of cooling) respectively.
During the SleepSense operation , if Big activity /movement is detected, the temperature and Fan speed
will resume back to previous setting.
During the SleepSense operation , if small activity /movement is detected, the temperature will decreased
( in case of cooling) and Fan speed will increase by one tapping.