Technical specifications
Article number
Nesting depth
S7 counter
Retentivity
IEC counter
Retentivity
S7 times
Retentivity
IEC timer
Retentivity
Flag
Data blocks
Local data
38
Number of DPV1 alarm OBs
Number of isochronous mode OBs
Number of technology synchronous alarm
OBs
Number of startup OBs
Number of asynchronous error OBs
Number of synchronous error OBs
Number of diagnostic alarm OBs
per priority class
Counters, timers and their retentivity
Number
adjustable
Number
adjustable
Number
adjustable
Number
adjustable
Data areas and their retentivity
Retentive data area (incl. timers, counters,
flags), max.
Extended retentive data area (incl. timers,
counters, flags), max.
Size, max.
Number of clock memories
Retentivity adjustable
Retentivity preset
6ES7518-4AP00-0AB0
3
3
2
100
4
2
1
 
24
 
 
2 048
 
Yes
 
Any (only limited by the main memory)
 
Yes
 
2 048
 
Yes
 
Any (only limited by the main memory)
 
Yes
 
768 kbyte; In total; available retentive memory
for bit memories, timers, counters, DBs, and tech­
nology data (axes): 700 KB
20 Mbyte; When using PS 6 0W 24/48/60 V DC HF
 
16 kbyte
8; 8 clock memory bit, grouped into one clock
memory byte
 
Yes
No
 
CPU 1518-4 PN/DP (6ES7518-4AP00-0AB0)
Equipment Manual, 11/2022, A5E32334527-AE