CT SERIES
WIRING PROCEDURES
FOR
1 PHASE FIELD MOTOR STARTER
TURN OFF POWER BEFORE SERVICING!!!
1. CONNECT MOTOR LEADS AS PER DIAGRAM ON MOTOR NAMEPLATE
TO STARTER TERMINALS T1 & T2.
2. CONNECT ONE WIRE FROM PRESSURE SWITCH TO STARTER
TERMINAL L1 (USE 18GA WIRE).
3. CONNECT 2
TERMINAL A2 (USE 18GA WIRE). A2 IS OPEN SPADE CLIP BEHIND L2.
4. CONNECT INCOMING POWER WIRES TO STARTER TERMINALS
L1 & L2.
ND
WIRE FROM PRESSURE SWITCH TO STARTER COIL
PAGE 30
CONNECT INCOMING
POWER WIRES TO
STARTER TERMINALS
L1 & L2.
CONNECT ONE WIRE
FROM PRESSURE SWITCH
TO STARTER TERMINAL
L1.
ND
CONNECT 2
WIRE FROM
PRESSURE SWITCH TO
STARTER COIL TERMINAL A2.
THERMAL UNIT
CONNECT MOTOR
LEADS TO STARTER
TERMINALS T1 & T2.