Start And Stop; Start The Inverter; Stop The Inverter; General Operation - Sunways STT Series User Manual

Grid-connected inverter
Hide thumbs Also See for STT Series:
Table of Contents

Advertisement

5 Start and Stop

5 Start and Stop
※ 5.1 Start the Inverter
When starting the inverter, follow these steps:
① Turn on the AC breaker first (close the AC circuit breaker).
② Turn on the DC switch in the bottom. If the PV string voltage higher than the inverter
start-up voltage, the inverter will start.
③ When both AC and DC power supply are normal, the inverter is ready to start. The
inverter will initiate checking its internal parameters and grid parameters, if it is within
the range, the green light on the left side of the screen begins to flash, and the "Waiting"
message will be displayed on the OLED display.
④ After self-checking completed, the inverter will start generating electricity, the green
light will remain on, and the OLED display will display real-time power information.
※ 5.2 Stop the Inverter
When turning off the inverter, please follow the steps below:
① Turn off the AC breaker first.
② Wait 30 seconds and then turn the DC switch to the "OFF" position. At this time,
there is remaining power in the inverter capacitor. Wait for 5 minutes until the inverter is
completely de-energized before conducting any work on the inverter.
③ Disconnect the AC and DC cables.
36

6 General Operation

※ 6.1 Display Operation
When the inverter is turned on, the following interfaces will be displayed on the OLED
display, and the OLED display allows the user to check various operation information and
to modify the settings of the inverter. Please refer to the following display operation flow
for details:
6.1.1 Main Window and General Setting
Main Window
Waiting
Checking
Normal
PV Voltage
PV Current
Grid Voltage
E-Day
E-Total
Grid Current
Grid Freq
Not WiFi/LAN
Modbus
LAN
Addr
setting
OR
OR
WIFI
Setting
setting
Language
Export Limit
Time Set
On/Off
Set
XXX%
Setting
Setting
Re-
Grid Connect
CT Ratio
Connect
Type Set
Setting
Setting
Setting
Sys
OverLoad
Power
CtrlMode
(AU)
Rate Limit
Setting
Setting
Setting
6 General Operation
Firmware
Fault info
Updating
Model
General
Advanvced
H-Total
Name
Settings
Settings
System
RSSI
Fault Info
Info
Error
SN/FM
Message
Version
Power Rate
Generation
Limit
Limit
XXX%Pn/min
XXX%
Power
Feed in
Export
Safety
Factor
Grid
Limit
Set
Setting
Setting
Setting
Setting
Generation
Limit
Setting
Short press(1s), switch window
Long press(3s), enter the lower menu
37

Advertisement

Table of Contents
loading

Table of Contents