USER MANUAL
DRAGON POWER 1-L
1 KVA - 3 KVA

Advertisement

Table of Contents
loading

Summary of Contents for LBS DRAGON POWER 1-L

  • Page 1 USER MANUAL DRAGON POWER 1-L 1 KVA - 3 KVA...
  • Page 2 Safety precautions Operation 1. Before usingthis product, please read "safety precautions" carefully to ensure correct and safe use, and please keepthe manual properly. 2. Duringoperation, please pay attention to all warning signsand operate as required. 3. Donot use the device in direct sunlight,rain or the humid environment. 4.
  • Page 3: Table Of Contents

    Content 1.Introduction ..........................1 1.1Symbol..........................1 1.2Rear view .........................2 1.3Specification ........................3 1.4Electromagneticcompatibility ..................4 2.Installation ..........................5 3.ControlPanel..........................5 3.1Panel display........................6 3.2Functionof button......................7 3.3UPS workingstatustable of LCDdisplay................8 3.4Parameter query......................9 3.5Functionsetting......................10 4.Warning code/faultcodeand solution ..................13 4.1Warning codeandsolution....................13 4.2Fault codeandsolution ....................14 4.3Commonfaultsandtrouble shooting................16 5.Controlandcommunication......................
  • Page 4: Introduction

    1. Introduction This series of UPS is an online sine wave uninterruptible power supply system with bypass maintenance switch, which can provide reliable and high-quality ACpower for your precision equipment. It can be used in a wide range, from computer equipment, communication system to industrial automatic control equipment.
  • Page 5: Rear View

    1.2 Rear view � Computerinterface � Smart slot(optional) � Externalbattery connection � USB � Input over currentprotection � ACINPUT � Output socket � EPO � Battery interface � Battery breaker(optional) ⑪ Maintenance bypassswitch (optional) ⑫ Output breaker(optional)
  • Page 6: Specification

    1.3 Specification Model DP1OL-3KTRL-120 Capacity 3kVA/3kW Input Nominal Voltage 100/110/115/120/127VAC, L+N+PE Voltage Range 55-150VAC Frequency 40-70Hz �0.99 Power Factor THDi ≤4% (linear load); ≤5% (non-linearload) Output Nominal Voltage 100/110/115/120/127VAC, L+N+PE Voltage Regulation ± 1 % Frequency 50/60Hz±0.1% CrestRatio Voltage HarmonicDistortion ≤2% (linear load);...
  • Page 7: Electromagneticcompatibility

    Loadat highaltitude=Rated power *Derating factor (correspondingto altitude) Altitude(m) 1000 1500 2000 2500 3000 3500 4000 4500 5000 Derating factor 100% Notice: If the machine is used at above 1000m,diminishing ratings output must be used, please refer to above table for derating factor. 1.4 Electromagneticcompatibility Safety IEC/EN 62040-1-1...
  • Page 8: Installation

    2. Installation 2.1 Setup the UPS Sep 1: UPS inputconnection Plug the UPS into a two-pole,three-wire, groundedreceptacle only. Avoidusingextensioncords. Step 2: UPS output connection For socket-typeoutputs, simply connect devices to the outlets. For terminal-type input or outputs, please follow below stepsfor the wiring configuration: a) Remove the smallcover of the terminal block.
  • Page 9: Panel Display

    3.1 Panel display Display Function Error message FAULT Failure occurred Warnings Fault code Mute Mute function Input and output voltage, DCvoltage, UPS internal temperature VAC:input and output voltage; VDC:DCvoltage ℃: UPS internal temperature; Hz:Frequency Loadinformation The load volume(0-25%, 26%-50%,51%-75%, 76%-100%) is shown here, andthe overload icon flasheswhen the battery is low or not connected Battery information The battery capacity(0-25%, 26%-50%,51%-75%, 76%-100%)is displayed...
  • Page 10: Functionof Button

    3.2 Function of button Button Functional Description ACMode: pressthe two buttons at the sametime for 1 Combokey for turningon the UPS secondabove to start UPS. Battery Mode: please press confirmation button first, after turning on the screen,please pressthe two buttons at the same time for 1secondabove to start UPS.
  • Page 11: Ups Workingstatustable Of Lcddisplay

    3.3 UPS workingstatus table of LCDdisplay ACMode LCDdisplay content Instruction UPS can provide stable ACoutput when ACinput in the permissible range.In ACMode, batteries will also be chargedby the UPS. Battery Mode LCDdisplay content Instruction When the ACinput isout of limited rangeor shutoff, the UPS will turn to Battery Mode.
  • Page 12: Parameter Query

    3.4 Parameter query Normally the LCDdisplay can show 8pagestotally. Pressing the query button 0.1-2seccan enter into the different pageswhich show all information, suchas input, battery, output, load, software version, temperature, and etc. If alarms occur,the display will add one more pageto show the alarm information.If the UPS hasfaults, the default displaywill turn to the Fault code pageautomatically, the home pagewill show the fault or alarm information by default.
  • Page 13: Functionsetting

    3.5 Function setting ●01: Outputvoltage LCDDisplay Setting 1. Press the function setting button over 2 sec, then goto the setting page.Press the pageturning buttonstill the setting pageof output voltage, and the word "OPU" flashing. 2. Press confirmation button 0.5-2sec, then go to the setting pageof output voltage OPU.The "OPU"...
  • Page 14 02-2Battery low voltage shutdownpoint/End ofdischargevoltage(EOD) LCDDisplay Setting The options of EOD setting are dEF, 9.8V, 9.9V,10V,10.2V,10.5V. By default, the EOD is dEF (The EOD will be changed accordingto loading condition. 10.5V@load<25%,10.2V@25%<load<50%,10V@load> 50%). 02-3:Economic Operation Mode LCDDisplay Setting ECOis OFF bydefault, can be set as ONto improve the efficiency of systemoperation.
  • Page 15 02-5:Battery quantity(PCS) LCDDisplay Setting When EP is set to ON,the PCSoption appearson the function setting page,will enter the passwordpage,enter the password (the general passwordis 135),you can set the number of batteries. Thedefault battery numberis 16pcs,whichcan be set to 16/18/20pcs. 02-6:ChargerCurrent(CHG) LCDDisplay Setting When EP is set to ON,the CHGoption appearson the functional...
  • Page 16: Warning Code/Faultcodeandsolution

    4. Warning code/faultcodeandsolution 4.1 Warning code andsolution " When the " symbolon the UPS LCDflashes,the UPS is in alarmstate. Press the pageturning keyto the error state page(refer to 3.5), observe the alarm code andmakeappropriate processingaccordingto the table below. Alarm Indication Possible reasons Treatment measures No battery...
  • Page 17: Fault Codeandsolution

    4.2 Fault code and solution " When the "FAULT"is longbright, and" symbolon the UPS LCDflashes, the UPS is in fault state. UPS automatically switches to the error status page(refer to 3.5) to observe the fault code and makeappropriate processingaccordingto the following table. Fault Indication Possible reasons...
  • Page 18 Negative power 1. Bypass reverses to the Checkthe loads and if no abnormal, protection(output inverter. please contact the supplier. with ACinput fail) 2. load abnormal Inv relay or SCR Relay RL8 is damaged. Please contact the supplier. open circuit Inv relay or SCR short circuit Bypass relay or Relay RL4/RL6is damaged.
  • Page 19: Commonfaultsandtrouble Shooting

    4.3 Commonfaults and trouble shooting Number Problem or errors description Reason Solution Connectto city electricity, No input power Checkif the input wiring and no display on LCDdisplay harnessof UPS is in well panel connection. Input voltage under Use voltagemeter to check voltage or overload the input voltage if in normal or meets the requirement.
  • Page 20: Controlandcommunication

    5. Controland communication UPS includesseveral communicationports: RS232,EPO, SNMP card, USB, and dry contact card. NOTICE:Only oneof SNMP card, and dry contact card can be usedat the sametime. Only one of RS232and USB is available at the sametime. 5.1 SNMP Card SNMP card is usedto monitor the UPS via TCP/IPprotocol, users can checkthe UPS status and data online.
  • Page 21: Epo

    UPS fail Bypass mode General alarm Battery low UPS is on 12~24VDC Remote shutdown Utility fail 5.3 EPO Theremote EPO islocated onthe rear panel of UPS. Its normal closed,if its open,it will active EPO function, the UPS will shutdown output.
  • Page 22: Battery Maintenance& Repair

    6. Battery Maintenance& Repair ●This series of UPS only needsvery little maintenance.Thebatteries of the standardmachine are seal type and noneed to maintain frequently. But also keepchargingto get the expected battery life. UPS keepschargingwhen it is connectingto AC,no matter on/off.Andif also have function of overchargingand overload protection.