Download Print this page

Giant P426HHP Operating Instructions/ Repair And Service Manual page 3

Triplex ceramic plunger pump

Advertisement

Flow (continuous) .........................................Up to 14.3 GPM ............. (54 L/min)
Flow (intermittent) .........................................18 GPM ........................... (68.1 L/min)
Maximum Discharge Pressure .....................Up to 3000 PSI ............... (200 bar)
Maximum Inlet Pressure ...............................145 PSI ........................... (10 bar)
Power Required ............................................27.1 BHP ......................... (20.7 kW)
Stroke ...........................................................0.97" ................................ (24.6 mm)
RPM (continuous) .................................................................................. 1450 RPM
RPM (intermittent) .................................................................................. 1825 RPM
Plunger Diameter ..........................................1.02" ................................ (26 mm)
Temperature of Pumped Fluids .....................Up to 160
Inlet Ports ...............................................................................(1) 1" BSP, (2) 3/4" BSP
Discharge Ports ..................................................................................... (2) 3/4" BSP
Crankshaft Bore ............................................SAE 2B or SAE 4B 13T 16/32 Spline*
Shaft Rotation ........................................................................................ Towards fluid end
Crankshaft Diameter .............................................................................. (28 mm)
Key Width .............................................................................................. (8 mm)
Shaft Mounting ....................................................................................... Either side
Weight ...........................................................39.7 lbs. .......................... (18 kg)
Crankcase Oil Capacity ................................27.1 fl.oz. ........................ (0.8 liters)
*J498b 30° Class 5
Consult the factory for special requirements that must be met if the
pump is to operate beyond one or more of the limits specified above.
NOTES:
In order to drive the pump from the side opposite the present shaft exten-
sion, simply remove the valve casing from the crankcase and rotate the
pumps 180 degrees to the desired position. Be certain to rotate the seal
case (item #20) as well, so that the weep holes are down at the six o'clock
position. Exchange the oil fill and the oil drain plugs, also. Refer to the
repair instructions as necessary for the proper assembly sequence.
To Determine the Torque of a Hydraulic Motor: Torque (in-lbs) = (GPM x PSI x 36.77) / RPM
P426HHP HORSEPOWER REQUIREMENTS
RPM GPM 1000 PSI 1500 PSI 2000 PSI 3045 PSI
785
7.7
5.3
900
8.9
6.1
1010 10.0
6.9
1120
11.1
7.7
1240 12.2
8.4
1450 14.3
8.8
Model P426HHP Specifications
8.0
10.6
16.2
9.2
12.3
18.7
10.3
13.8
21.0
11.5
15.3
23.3
12.6
16.8
25.6
14.8
19.7
30.0
U.S.
o
F ................... (70
SPECIAL NOTE:
The theoretical gallons per revolution
(gal/rev) is 0.00986. To find specific
outputs at various RPM, use the
formula: GPM = 0.00986 x RPM
3
(Metric)
o
C)
1

Advertisement