Advertisement

The peculiarity of GMDSS is highly reliable communication by automation and
digitalization.
S RG- 1150DN/S RG- 1250DN with S N- 100 TERMINAL is consists of a MF /HF
transmitter, MF/HF receiver, DS C (Digital Selective C alling) w/k receiver, NBDP
receiver, DSC , distress alarm telephone. All of these are to communicate digitalized
data properly for distress safety and general communication.
T he range o f
frequency
J 3E
150W(HIGH)/100W(MID)/50W(LOW)
The typ e
o f
H3E
75W(HIGH)/16W(LOW)
em ission
F1B
100W(HIGH,MID)/75W(LOW)
1.1 FEATURES
(1) Possible range
Because MF /HF transceiver, DS C W/K receiver, DSC , Distress alarm telephone is
built in SRG- 1150DN/SRG- 1250DN, you are able to use itself without NBDP
terminal. NBDP function works by connecting SN- 100 TERMINAL, but it is not
available to use NBDP TERMINAL only.
(2) Total C ontrol S ystem
SRG- 1150DN/SRG- 1250DN is set up with the major modules combined as one unit
or circuits within a single cabinet. Thus, it is possible to rationalize the total c ontrol
system by interlinking the respective module controls.
And Narrow Band Direct Printing is available by connecting NBDP unit(S N- 100) to
S RG- 1150DN/1250DN simply.
1. OVERVIEW
S RG -1 1 5 0 DN
T ra ns miss ion : 1.6MHz ~ 27.5MHz
Receiving : 500KHz ~ 29.9999KHz
SRG-1150DN / SRG-1250DN / SN-100
S R G - 1 2 5 0 D N
250W(HIGH)/100W(MID)/50W(LOW).
75W(HIGH)/16W(LOW).
150W(HIGH)/100W(MID)/75W(LOW)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SRG-1150DN and is the answer not in the manual?

Questions and answers

Summary of Contents for Samyung ENC SRG-1150DN

  • Page 1 Thus, it is possible to rationalize the total c ontrol system by interlinking the respective module controls. And Narrow Band Direct Printing is available by connecting NBDP unit(S N- 100) to S RG- 1150DN/1250DN simply. SRG-1150DN / SRG-1250DN / SN-100...
  • Page 2 And each keys are made by soft rub material, it has stylish shape and makes you feel comfortable when you press the button. Futhermore there is frequency sheet for users. S N- 100 NBDP TERMINAL has large, thin, c olorful LCD and convenient keyboard. SRG-1150DN / SRG-1250DN / SN-100...
  • Page 3: Basic Components

    R E M A R K A L A R M B O X SD-250 O P T I O N MF/ HF A NT (WHIP ) K U M- 8 0 3 O P T I O N SRG-1150DN / SRG-1250DN / SN-100...
  • Page 4 A L A R M B O X SD-250 O P T I O N D S C ANT ( WH IP ) K U M - 8 0 3 O P T I O N SRG-1150DN / SRG-1250DN / SN-100...
  • Page 5: General Specification

    : 288(W) X 312(H) X 166(D) (unit : mm) * SN- 100 : 300(W) × 255(H) × 125(D) (unit : mm) S RG- 1150DN/S RG- 1250DN : 8.5Kg o Weight S N- 100 : 5Kg SRG-1150DN / SRG-1250DN / SN-100...
  • Page 6 5 0 0 H z 43dB or more o Overall Frequency Deflection 6dB max. at 350 - 2,700Hz o Overall Distortion 20dB or more & Noise o Input Low Frequency +10dB/- 35dB, IMPE DANC E 600 ohm SRG-1150DN / SRG-1250DN / SN-100...
  • Page 7 The detailed characteristics of 0.3KHz F ILTER (for DS C , NBDP) The passband below 6dB is 270Hz- 300Hz Attenuation at ± 380Hz is 30dB or more Attenuation at ± 550Hz is 60dB or more SRG-1150DN / SRG-1250DN / SN-100...
  • Page 8 500Hz from the want signal, the c harac ter error rate is less than 1× 10 The power of emission from air antenna terminal is o S purious emission 4000㎼ or less. o Nominal input load 50 ohm unbalanc ed SRG-1150DN / SRG-1250DN / SN-100...
  • Page 9: Automatic Alarm

    Within 1300Hz ± 1.5% o Frequency and Deflec tion Within 2200Hz ± 1.5% o Each Alarm for long & E rror 250ms ± 50ms o Alarm Intervals 50ms o Amplitude Rates of Alarm Less than 1.2 SRG-1150DN / SRG-1250DN / SN-100...
  • Page 10 10- bit error detection c ode as spec ified in C C IR 493- 8 standard. o Processor * Correction of C LOC K transmission type CLOCK frequency : 14,000kHz CLOCK stability : within ± 5× 10 SRG-1150DN / SRG-1250DN / SN-100...
  • Page 11 S hift Range o Modulation S peed 100 baud (ARQ, F EC mode) o Modulation Phase- continuous AFSK o Frequency deviation Within 0.5Hz o Demodulation Input 0dBm, 600ohm unbalanced/balanced o Modulation Output 0dBm, 600ohm unbalanced/balanced SRG-1150DN / SRG-1250DN / SN-100...
  • Page 12: Printer (Dpu-414)

    Temperature : 0℃ ~ 40℃ Humidity : 30% ~ 80% RH(at no condensation) 4. PRINT PAPER Model No. : TP411 ~ 28C L (TP- 411L) Width : 112mm Diameter : 48mm Length : 28m approx. SRG-1150DN / SRG-1250DN / SN-100...
  • Page 13 * Noise L e v e l : Less than 55 dBA * Power R equirements : 230V AC (+6%, - 14%), 240V AC (± 10%) * F re q ue nc y : 50/60 Hz SRG-1150DN / SRG-1250DN / SN-100...
  • Page 14 Paper path 2 : Bottom paper feed for continuous forms with straight paper path Paper path 3 : Top feed of single, cutsheet forms S tandard paper handling : Rear feed Bottom feed Top feed SRG-1150DN / SRG-1250DN / SN-100...
  • Page 15: Power Supply

    AUTO MO DE - When the battery is low, automatically charge. The default is auto mode. NORMAL  MODE - Regardless of battery status, charge the battery. To make battery life long, it needs repair properly. Refer to the manual. SRG-1150DN / SRG-1250DN / SN-100...
  • Page 16: Front Panel

    ④ FRONT PANEL (LCD) - DISPLAYS CHANNEL / FREQUENCY / MODE ⑤ ARTICULATION - ADJUST ARTICULATION(TO RECEIVE SIGNAL CLEARLY) ⑥ GAIN - ADJUST AF GAIN ⑦ VOL - ADJUST SPEAKER VOLUME ⑧ CHANNEL - ADJUST CHANNEL AND FREQUENCY UP AND DOWN ⑨ KEY PANEL SRG-1150DN / SRG-1250DN / SN-100...
  • Page 17 RECEIVING : RX SIGNAL OR POWER VOLTAGE(24V) TRANS MITTING : END CURRENT OR ANT C URRENT POWER - ON / OFF. C ANC EL SETTING OR RETURN TO PREVIOUS MENU. TRANSMISSION MODE OF DIS TRES S ALARM SIGNAL SRG-1150DN / SRG-1250DN / SN-100...
  • Page 18 ANS WERING MODE ON/OFF PRINT REC EIVED FREQUENC Y/C HANNEL STOP ALARM, OFF THE INDIC ATORS OF DIS TRES S , C ALL. C OMMUNIC ATION MODE BY S S B TELEPHONE C OMMUNIC ATION MODE BY DSC SRG-1150DN / SRG-1250DN / SN-100...
  • Page 19 INDIC ATOR IS TURNED ON EXCEPT OF DIS TRES S SIGNAL. LED INDIC ATOR - WHILE TRANS MITTING, LED INDIC ATOR IS TURNED ON. LED INDIC ATOR - WHEN W/K RECEIVER IS AC TIVATED, LED INDIC ATOR IS TURNED ON.(ALWAYS WORKING) SRG-1150DN / SRG-1250DN / SN-100...
  • Page 20 * MODE, BAND WIDTH, AGC , NOIS E BLANKER, ATTENUATOR AND S P E A K E R S TATUS IN RECEIVING PRAT * INDIC ATE KEY INPUT(REFER TO OPERATION ITEMS IN C OMMUNIC ATION MODE) INDIC ATOR W/K FREQUENC Y SCANNING [ SPK] KEY - ON / OFF SRG-1150DN / SRG-1250DN / SN-100...
  • Page 21 FREQUENC Y WITH [ C H] DIAL OR NUMBER KEY. RxG:00.0% BE DISPLAY RX SIGNAL & POWER VOLTAGE(24V) WITH S ETTING AT THE RECEIVING THAT BE DIS PLAY END C URRENT & ANTENNA C URRENT WITH SETTING AT THE TRANS MITTING SRG-1150DN / SRG-1250DN / SN-100...
  • Page 22 [ ENTER] Key AND THEN ON/OFF. (When setting up : ▶ ) 2002. 4. 6 N 3 5 . 0 5 E 129.03 : GPS DATA SIGNAL (Lat. Lot.) While c hanging channels, indicate tuning condition SRG-1150DN / SRG-1250DN / SN-100...
  • Page 23 5. Geography msg edit 6. Auto / Semi - AT msg edit 7. Dist. ac k/rly msg edit 8. Ordinary ack msg edit 9. Display & S end msg 0. System SET 2182 MAIN MENU SRG-1150DN / SRG-1250DN / SN-100...
  • Page 24 (1) S elect by [ SSB] KEY If pressing [ SSB] KEY of FRONT PANEL, set to SSB MODE as follows. 5.2 SSB MENU DISPLAY * If pressing [ MENU] KEY at SSB mode display, menu display is indicated as follows. SRG-1150DN / SRG-1250DN / SN-100...
  • Page 25 [ Last] : Set last frequency of S c an Frequency. [ Speed] : S et S c an Frequency S peed. [ S tep] : S et S canning frequency S TEP(100HZ per 1S tep) ex ) When‘ 100’ - 10KHz STEP SRG-1150DN / SRG-1250DN / SN-100...
  • Page 26: Manual Tuning

    (7) MANUAL TUNING a) When turning manually, menu is used. b) After [ 8.Manual Tuning] is inverted us ing [ ▲ ] [ ▼ ] KEY, press [ ENTER] KEY and then display as follows. SRG-1150DN / SRG-1250DN / SN-100...
  • Page 27: System Set

    S elect ANT, 24V, S WR, IC . RxG(RX signal level), ANT means (Antenna C urrent), 24V(Power Voltage), S WR(Reflected Wave C urrent), IC (End C urrent). ANT, S WR, IC is indicated at TX SRG-1150DN / SRG-1250DN / SN-100...
  • Page 28 Press [ ENT] , display as follows for each frequency by turns. Freq 2,032.0khz Tune Tuning - - - ⑧ [ 8.S elf Test] : S elf test func tion. Press [ ENT] , display as follows. Version Receiver good Watch-R good Exciter good Tuner good SRG-1150DN / SRG-1250DN / SN-100...
  • Page 29 : In c ase of emergency only * CH17 ˜ C H19 : C an be used by user. press [ SCAN] key, scan only in spec ified data location within CH17 ˜ C H19. SRG-1150DN / SRG-1250DN / SN-100...
  • Page 30 ) After selecting c hannel1 with [ ▲ ] [ ▼ ] [ ◀ ] [ ▶ ] key, press [ ENTER] key and the message edit screen is set as follows. FORMAT Distress NATURE Undesigreted POSITION DIST-UTC TEL C M D SRG-1150DN / SRG-1250DN / SN-100...
  • Page 31 : S how the completion of DS C message.(End Of S equenc e) EOS - Be set automatically (Fixed) d) S aving of the message Press [ 1] , show [ ...File S aved...] and be s aved. SRG-1150DN / SRG-1250DN / SN-100...
  • Page 32 08,200.0 08,200.0 Ack RQ ① [ TX- Freq] : Indic ate TX frequency. 2,187.5 4,207.5 6,312.0 8,414.5 12,577.0 16,804.5 8,414.5 ※ Indicate the frequencies which is memorized by user in DS C mode CH7˜ 19. SRG-1150DN / SRG-1250DN / SN-100...
  • Page 33 AIA m orse F1C/F2C/F3C No information ⑥ [ TEL C MD2] : S et Telecommand2 Telecommand is changed by [ TEL CMD 1] <J 3E> ship and aircraft medical transport pay phone call offics No information SRG-1150DN / SRG-1250DN / SN-100...
  • Page 34 ④ While selec ting WORK FRQ, press [ 3] then show the frequency list whic h is registered till then. T x F re q . R x F req. ↓ ↓ 01 : 10, 000.0/20, 000.0 02 : 14, 000.0/14, 000.0 03 : 04 : 50 : SRG-1150DN / SRG-1250DN / SN-100...
  • Page 35 ※ Moreover, indicate the frequency memorized by user in DSC MODE CH7 ~ C H19. ② [ FORMAT] : Show a kind of c all. G R OUP - S howi ng a g roup c all ( F i x ed) SRG-1150DN / SRG-1250DN / SN-100...
  • Page 36 ⑦ [ WORK FRQ] : S et a operational frequenc y. ⑧ [ E O S ] : Show the completion of DSC message (End Of Sequency) E OS - B e s et automati c al l y ( F i x ed) SRG-1150DN / SRG-1250DN / SN-100...
  • Page 37 ( NO DA T A ) C H = 301 ( NO DA T A ) C H = 302 ( NO DA T A ) … … C H = 399 ( NO DA T A ) SRG-1150DN / SRG-1250DN / SN-100...
  • Page 38 A L L S hi p - S howi ng all of the s hi ps ( F i x ed) ③ [ C ATE GORY ] : S et a purpose of call. S a f e t y Urg enc y Di s tres s ・ SRG-1150DN / SRG-1250DN / SN-100...
  • Page 39 ⑥ [ WORK FRQ] : S et a operational frequency. ⑦ [ E O S ] : S how the completion of DS C message.(End Of Sequency) E OS - B e s et automati c al l y ( F ix ed) SRG-1150DN / SRG-1250DN / SN-100...
  • Page 40 (5) Geog raphy msg edit a) Use in a definite area. b) After converting [ 5.Geography msg edit] with [ ▲ ] [ ▼ ] key, press [ ENTER] key and the screen is set as follows : SRG-1150DN / SRG-1250DN / SN-100...
  • Page 41 A l i mi t on l ati tude ( the v al ue of offs et) Do - A l i mi t on l ong i tude( the v al ue of offs et) SRG-1150DN / SRG-1250DN / SN-100...
  • Page 42 ⑧ [ E O S ] : Show the completion of DSC message. ( End Of S equenc y) E OS - B e s et automati c al l y ( F ix ed) SRG-1150DN / SRG-1250DN / SN-100...
  • Page 43 ( NO DA T A ) C H = 301 ( NO DA T A ) C H = 302 ( NO DA T A ) … … C H = 399 ( NO DA T A ) SRG-1150DN / SRG-1250DN / SN-100...
  • Page 44 A T /s emi- A T - S howi ng A T /s emi - A T c al l i ng ( F i x ed) ③ [ C ATE G ORY ] : Set a purpose o f call. R outine - A us ag e ( F ix ed) ④ [ PARITY ID] : Input ID SRG-1150DN / SRG-1250DN / SN-100...
  • Page 45 : S how the completion of DS C message.(End Of Sequency) A C K R Q - B E S E L E C T E D .( E S T A B L IS HE D) SRG-1150DN / SRG-1250DN / SN-100...
  • Page 46 ④ While selec ting WORK FRQ, press [ 3] then show the frequency list which is registered till then. Tx F req. Rx Freq. 01 : 10, 000.0/20, 000.0 02 : 14, 000.0/14, 000.0 03 : 04 : 50 : SRG-1150DN / SRG-1250DN / SN-100...
  • Page 47 A c k R Q ※ In case there is other vessel in distress or it's not able to send distress signal, this function can be used instead of 'Distress S ignal' by pressing [ CALL] . SRG-1150DN / SRG-1250DN / SN-100...
  • Page 48 L i s t i n g S i nk i ng A d r i f t Undes i g nated A bandon s h i p P i rac y /A ttac k Man Ov erboard SRG-1150DN / SRG-1250DN / SN-100...
  • Page 49 F 1B /J 2B F ec ⑫ [ E O S ] : Show the completion of DSC message (End Of Sequency) E OS - B e s et automati c al l y ( F ix ed) SRG-1150DN / SRG-1250DN / SN-100...
  • Page 50 ) [ ▲ ] [ ▼ ] - Move channel 1 by 1 (up/down) [ ◀ ] [ ▶ ] - Move c hannel 10 by 10 (up/down) d) Able to answer pressing [ CALL] key. SRG-1150DN / SRG-1250DN / SN-100...
  • Page 51 S et W K R S c a n S et D a t a C l ear P rinting D a t a T rans mi t Ds c - E t c S et SRG-1150DN / SRG-1250DN / SN-100...
  • Page 52 ㄱ ㄲ ㄴ ㄷ ㄸ ㄹ ㅁ ㅂ ㅃ ㅅ ㅆ ㅇ ㅈ ㅉ ㅊ ㅋ ㅌ ㅍ ㅎ ㅏ ㅐ ㅑ ㅒ ㅕ ㅓ ㅔ ㅕ ㅖ ㅗ ㅛ ㅜ ㅠ ㅡ ㅣ Input : SRG-1150DN / SRG-1250DN / SN-100...
  • Page 53 → Data expect Distress data in the received data ※ Using [ ▼ ] [ ▲ ] keys, after reverting the spot you want press [ ENT] , then it shows as follows. Y e s SRG-1150DN / SRG-1250DN / SN-100...
  • Page 54 If press [ Distress] key for 3 sec. P res s S top K ey display and if press [ S TOP] , Ok . ( P res s any K ey ) display. SRG-1150DN / SRG-1250DN / SN-100...
  • Page 55 When press [ 2182] key of Front PANEL, be display as follows : b) Only transmitting is not working in this mode. c) If you want to make test stop, press [ S TOP] . SRG-1150DN / SRG-1250DN / SN-100...
  • Page 56 After revert [ DISTRESS SEND] key, transmit distress signal pressing [ E NT] . b) If you want to make TX stop, press [ S TOP] . c ) Revert to S S B mode pressing [ S S B] , C HANNEL dial, [ SSB] key. SRG-1150DN / SRG-1250DN / SN-100...
  • Page 57 Then "Distress" LED blink that means the position, time, ship ID will be sent. ■ ※ Receiving channel range is from 1 to 6 as follows. 2, 187.5 4, 207.5 6, 312.0 8, 414.5 12, 577.0 16, 804.5 SRG-1150DN / SRG-1250DN / SN-100...
  • Page 58 If there is no answer, it shows as follow screen. After "3min. 50sec .", Then it will try transmitting again from channel 1 through c hannel 6 till getting an answer. ■ c) If you want to stop transmitting, press [ S TOP] . SRG-1150DN / SRG-1250DN / SN-100...
  • Page 59: H O W T O U S E P R I N T E R

    On pressing this switch once, it will be feed once and on pressing this switc h c ontinuously, it will be kept feeding. c ) C utter : Use for cutting the printer paper. d) Exit of paper : it is the part where the paper is ejected through it. SRG-1150DN / SRG-1250DN / SN-100...
  • Page 60 Store up the center shaft and the paper gets out of the way- out. g) Press FEED KEY until the end of paper gets out of the way- out. h) Close the PAPER COVER and put it down to shut. SRG-1150DN / SRG-1250DN / SN-100...
  • Page 61 HEX- dump mode: turn the printer ON while holding down the SELECT and FORM FEED buttons. Hex mode generates data rather than test and a sample is shown below. To terminate this mode, switch the printer off and on again. SRG-1150DN / SRG-1250DN / SN-100...
  • Page 62 Line Feed Button. This print out illustrates the various styles of printing available from the ML184Turbo. Once printed, the printer automatically reverts to 10c pi Utility mode. An example of the DE MO PAGE IS ON THE NEXT PAGE . SRG-1150DN / SRG-1250DN / SN-100...
  • Page 63: Paper Loading

    Place the box of paper behind the printer. c ) Remove the access cover and lift the column indic ator bar. d) Open the paper release lever. e) Insert the first sheet of paper in the paper guides. SRG-1150DN / SRG-1250DN / SN-100...
  • Page 64 Turn the platen knob to advance the paper until it appears in front of the platen. h) Lower the column indic ator bar. I) Close the paper release lever. j) Use the platen knob to advance the paper to the first printing line. k) Replace the access cover. SRG-1150DN / SRG-1250DN / SN-100...
  • Page 65 1. If AC power is turned off, POWER LED will started blinking with "bip- " sound. When bip is stoped, press Reset Key. 2. POWER LED keep blinking while the equipment is operated by DC power. SRG-1150DN / SRG-1250DN / SN-100...
  • Page 66 C ONTROL C irc uit DS C C irc uit S AT- 100 MF /HF Transmitting, Rec eiving C irc uit W/K Rec eiving C irc uit PRINTE R Power C irc uit SRG- 1150DN BLOCK DIAGRAM SRG-1150DN / SRG-1250DN / SN-100...
  • Page 67: Power Circuit

    ⑴ Main power c irc uit and power c ontrol circuit SWITCH ON main power DC 24V when turn on and convert constant voltage to +15v, +12v . EXT. supply power even in AMP of speaker and S N- 100 TERMINAL. SRG-1150DN / SRG-1250DN / SN-100...
  • Page 68 2‘ nd LOC AL 49MHZ and 2’ nd MIXER Q7, Q8 and make 455KHZ IF . This signal bec ome filtering through J 3E(XL2), H3E(XL1) FILTER according to MODE. Again, amplify in Q1,IC6 and mix S S B and H3E in IC7. SRG-1150DN / SRG-1250DN / SN-100...
  • Page 69 ) Eac h circuit board c onnec ted by this circuit board arranged c onnec tors mec hanic ally not to inc orporate in wrong- position. SCHEMATIC IS AS FOLLOW. SRG-1150DN / SRG-1250DN / SN-100...
  • Page 70 S RG- 1150DN/S RG- 1250DN F REQUENC Y SYNTHESIZER. ① MF /HF unit S YNTHES IZER PLL(IC 8) and VCO(2MVCO) output as MF/HF 1‘ st LOC AL input signal (49.455MHZ ~ 79.4549MHZ) and 7MHz from OUTPUT of DDS 3 makes 49MHZ in 7 SRG-1150DN / SRG-1250DN / SN-100...
  • Page 71 TX C URRENT happen through BiMOS Operational Amplifiers(IC 3), AUDIO signal(C ONNEC TOR 6PIN, 5PIN) c onnec t PHONE J AC K through amplifier(IC 6). 10.9 PA AMP(SRG-1150DN : T-514, SRG-1250DN : T-524) This PC B circuit consists of TX output POWER AMP, TX output is 150W(S RG- 1150DN) and 250W(S RG- 1250DN).
  • Page 72 CRYSTAL FILTER of center frequency 49MHz passing band about 15KHz and amplify through 1st intermediate amplifier and is supplied in 2 mixture part. Receiving signal as 2 mixture part is mixed with 2 signal supplied from SRG-1150DN / SRG-1250DN / SN-100...
  • Page 73 PROGRESS in panel side, scanning- cease, output of receiving frequency is carried on C PU c irc uit T- 557. RESET of c irc uit picking DOT PATTERN c arry on RESET signal from DS C equipment. SRG-1150DN / SRG-1250DN / SN-100...
  • Page 74 ④ EXT.J ACK : EXTERNAL SPEAKER C ONNEC TING J AC K ⑤ W/K ANT : IMPEDANC E 50- 75Ω W/K RECEIVING ANTENNA J ACK. ⑥ C AR CONNECTOR S UPPLY C ONNEC TOR EQUIPMENT POWER SRG-1150DN / SRG-1250DN / SN-100...
  • Page 75 ⑩ ALARM BOX : CONNECTOR WHIC H WITH CONNECTED WITH SD- 250 ⑪ AC/DC DETECTOR : POWER UNIT AC/DC DETEC TION ⑫ TERMINAL C ONTROL : CONNECTOR BETWEEN SRG- 1150DN/SRG- 1250DN AND S N- 100(NBDP TERMINAL). SRG-1150DN / SRG-1250DN / SN-100...
  • Page 76: Nbdp T E R Mina L

    ② S PEAKER : ALARM RINGS WHEN IT RECEIVES DATA OR WARNING SIGNAL. ③ TX LED : RED LIGHT ON TX LED ④ RX LED : GRE E N LIGHT BLINKS WHILE RECEIVING DATA ⑤ POWER SWITCH : SN- 100 POWER ON/OFF SRG-1150DN / SRG-1250DN / SN-100...
  • Page 77 Adjust the portion of RF GAIN properly using up/down with direction RF GAIN keys. (0~ 1steps) CLARIFY Adjust the number properly using up/down direc tion key. (± 10Hz) Adjust attenuator 4 steps using up/down direction key. SRG-1150DN / SRG-1250DN / SN-100...
  • Page 78 [ Editor] : Edit file and save content [ System Set] : Use while adjusting TELEX mode condition. [ NBDP Test] : Transmitting signals of Dot, Mark, S pace. Use for testing printer and NBDP TX/RX condition. SRG-1150DN / SRG-1250DN / SN-100...
  • Page 79 Press [ F8] key. b) Input the frequency with number key. (While inputting frequency if press [ →] ,[ ←] , c urser will move.) c) Press [ ENT] NOTE!!) Available RX Freq. range : 95KHz ~ 29.99999MHz SRG-1150DN / SRG-1250DN / SN-100...
  • Page 80 Revert the channel you want to communicate using [ →] ,[ ←] key. And then press [ ENT] key. S et TX/RX frequency to registered freq. on c hannel displaying the first dis play of NBDP. SRG-1150DN / SRG-1250DN / SN-100...
  • Page 81 Press [ F2] key, displaying as following screen. b) S elec t [ ARQ] and press [ ENT] , then it will be connected with other party through ARG mode in present setting C hannel. SRG-1150DN / SRG-1250DN / SN-100...
  • Page 82 ※ C onnecting specific station a) C all the menu pressing [ F10] to call SUB MENU. b) S elec t ARQ from the above menu, press [ ENT] then display the screen as follow. SRG-1150DN / SRG-1250DN / SN-100...
  • Page 83 * If you want to make calling stop, can be back to the Telex first display b y pressing [ F8] . f) In c ase that the connecting is done properly, you can see the c urser in the left- up side of the screen. SRG-1150DN / SRG-1250DN / SN-100...
  • Page 84 Press [ F5] and after selecting the command, press [ ENT] . c ) Can be transmitted displaying c ontents of C ommand on the screen. * Pressing [ F8] is able to stop transmitting. SRG-1150DN / SRG-1250DN / SN-100...
  • Page 85 (1) C onnecting the other station by S elec tive FEC mode. * Communication with present selec ting C hannel. a) Press [ F2] and display sc reen as below. b) S elec t [ FEC] and press [ ENT] , then below screen is displayed. SRG-1150DN / SRG-1250DN / SN-100...
  • Page 86 [ S FEC ] mode. * To stop c alling , press [ F8] . f) As long as connecting with the other station, a curser will be displayed on the left- up side of the screen. SRG-1150DN / SRG-1250DN / SN-100...
  • Page 87 (2) C onnecting with the other station by collective FEC mode a) C all SUB menu with pressing [ F 10] . b) After selecting [ FEC ] , press [ ENT] key. Then follow display is showed. SRG-1150DN / SRG-1250DN / SN-100...
  • Page 88 * Enter - S end one line. * Shift(on the left) + Space - C onvert language. (English, Russian) NOTE!!) It is possible while the present language is Russian only. * F2 : 'Hereis' - Transmit Answer back code of yourself. SRG-1150DN / SRG-1250DN / SN-100...
  • Page 89 Press [ F5] . b) After selec ting the command, press [ ENT] . c ) Can be transmitted displaying c ontents of C ommand on the screen. * Pressing [ F8] is able to stop transmitting. SRG-1150DN / SRG-1250DN / SN-100...
  • Page 90 11.6 OTHER SEA STATION OR SHIP STATION EDIT & RESISTER FREQUENCY a) C all the S UB menu pressing [ F10] . b) After selecting Station Edit, press [ ENT] . Then following is displayed. SRG-1150DN / SRG-1250DN / SN-100...
  • Page 91 After inputting Tx Freq., press [ E NT] . j) After selec ting Rx channel, press [ ENT] . k) After inputting Rx Freq. press [ E NT] . l) Press [ ES C ] key to change to the first display. SRG-1150DN / SRG-1250DN / SN-100...
  • Page 92 After selecting Station Print, press [ ENT] . Then following is displayed. c) After selec ting the other station you want to communicate, press [ ENT] . Then selected frequency of the other station is printed. SRG-1150DN / SRG-1250DN / SN-100...
  • Page 93 After selecting 'Macro C ommand', press [ ENT] . Then the following is displayed. c) S elect the number of C ommand using [ →] ,[ ←] ,[ ↓ ] ,[ ↑ ] . d) After inputting 'C ommand' by keyboard, press [ ENT] . SRG-1150DN / SRG-1250DN / SN-100...
  • Page 94: Editor Mode

    C all the SUB menu pressing [ F 10] . b) S elect Editor and press [ ENT] , then following sc reen is displayed. c ) Writing and modifying c ontents is possible. In order to finish, press [ ENT] . SRG-1150DN / SRG-1250DN / SN-100...
  • Page 95 2. Answer Back Code 3. Collective FEC Receiving 4. Maximum FEC Error Ratio 5. NAVTEX Station Selection 6 . NAVTEX Message Selection 7 . NAVTEX ID Data Clear 8 . ID Printing 9 . Etc. Setting SRG-1150DN / SRG-1250DN / SN-100...
  • Page 96 * After doing as follow (1), operate the procedure as below. a) S elect Navtex Message and press [ ENT] . b) Whether receiving message or not is selectable. But, A, B, C , D are being received continuously. SRG-1150DN / SRG-1250DN / SN-100...
  • Page 97 - 2. Printer Poter : Local(printing from main unit) or REMOTE(printing from terminal). - 3. Date Set : Set the date. - 4. Time S et : Set the present time. - 5. Data C lear : Can erase memory data or data of Edit- File. SRG-1150DN / SRG-1250DN / SN-100...
  • Page 98 (5) NBDP Rx/Tx Test - Check NBDP terminal condition by transceiving the signal. (6) Freq- S hift C orrec t - The function which receiving 14MHz+1400Hz from receiving terminal and correct terminal 1st LOC AL frequency. SRG-1150DN / SRG-1250DN / SN-100...
  • Page 99 To off LC D selec t LCD Off and press [ E NT] . c ) Even LCD is turned off, other functions are available and if key is pressed or receive the data, then LC D is turned on. SRG-1150DN / SRG-1250DN / SN-100...
  • Page 100 And while power on, it makes ON main power DC 24V, convert constant voltage +12V, +8V, +5V. If it is over powered +32V, then power off. Prevention to reversing voltage c irc uit is built- in. SRG-1150DN / SRG-1250DN / SN-100...
  • Page 101 ⑧ PRINTER POWER : CONNECTOR WHIC H S UPPLIES +24V, +8V, GND TO PRINTER ⑨ FUS E : 3A FUSE (POWER S UPPLY F US E) ⑩ C ONNEC TOR TO MAIN UNIT : TRANSCEIVING PTT IN, PTT OUT, READY, DATA AF+, AF- . SRG-1150DN / SRG-1250DN / SN-100...
  • Page 102: Troubleshooting

    Is it O.K c onnec t condition & insulation of air antenna and connecting parts between transmitter receiver. d) check the Travelling wave and reflection frequency after connect high- frequency power supply to transmitter receiver and coaxial c able. SRG-1150DN / SRG-1250DN / SN-100...
  • Page 103 C heck air antenna connection for DS C . b) Check T- 552 PCB or T- 553 PC B of inside of equipment, if this part is not good, have to change same goods. SRG-1150DN / SRG-1250DN / SN-100...
  • Page 104 5. In c ase of checking or modulating, pay attention to the difference when measuring instrument is connected into each circuit or not. 6. All maintenance had better be carried out in our agent or SAMYUNG ENC CO., LTD. SRG-1150DN / SRG-1250DN / SN-100...

This manual is also suitable for:

Srg-1250dn

Table of Contents

Save PDF