Quick Start Guide
ENGLISH
Data Logger
Models DL913 & DL914
DATA LOGGERS
WITH AEMC
INSTRUMENTS
®

Advertisement

Table of Contents
loading

Summary of Contents for Chauvin Arnoux AEMC DL913

  • Page 1 Quick Start Guide ENGLISH Data Logger Models DL913 & DL914 DATA LOGGERS WITH AEMC INSTRUMENTS ®...
  • Page 2: Statement Of Compliance

    Statement of Compliance Chauvin Arnoux , Inc. d.b.a. AEMC Instruments ® ® certifies that this instrument has been calibrated using standards and instruments traceable to international standards. We guarantee that at the time of shipping your instrument has met its published specifications.
  • Page 3: Product Packaging

    PRODUCT PACKAGING (1) of the following: Data Logger Model DL913 / Data Logger Model DL914 Cat. #2153.61 / Cat. #2153.62 (1) Small Classic Tool Bag (1) 10 ft USB A to USB B cable Cat. # 2133.72 Cat. #2136.80 Also Included: (1) Quick Start Guide (1) USB Stick with User Manual &...
  • Page 4 Thank you for purchasing a Data Logger Model DL913 or DL914. For the best results from your instrument, read the operating instructions, and comply with the precautions for use. Signifies that the instrument is protected by double or reinforced insulation CAUTION - Risk of Danger! Indicates a WARNING.
  • Page 5: Precautions Before Use

    Precautions Before Use These instruments comply with safety standard IEC 61010-2-032: Ed4 for voltages and categories of installations at an altitude below 6500 ft (2000 m) and are rated for 600 V CAT IV installations with a degree of pollution equal to 2. Failure to observe the following safety instructions may result in electric shock, fire, explosion, damage to the instrument, or damage to other equipment.
  • Page 6: Other Configuration Settings

    2. If prompted, restart the computer after installation is complete. 3. Connect the instrument to the computer using Wi-Fi Direct or a USB cable. 4. Wait for the drivers to install. The drivers are installed the first time the instrument is connected to the computer. The operating system will display messages to indicate when they are installed.
  • Page 7 These tasks can be completed through either the instrument front panel or DataView . In addition, the Control Panel allows you to set a number of other ® parameters, including configuring Permanent mode, changing communication settings, erasing memory, and others. Detailed information for configuring the instrument via the DataView Data Logger Control Panel is available by pressing the Help button.
  • Page 8: Making Measurements

    Recording Mode: 1. Press either ◄ or ► until is highlighted. 2. Use ▲ or ▼ to display the rEC screen. 3. Press to cycle between normal recording mode and extended recording mode. In normal recording mode, the instrument records a sample every second. In extended recording mode, the instrument’s storage interval is 1/4th of the aggregation period.
  • Page 9: Remote User Interface

    If the instrument is returned for calibration, we need to know if you want a standard calibration or a calibration traceable to N.I.S.T. (includes calibration certificate plus recorded calibration data). Ship To: Chauvin Arnoux , Inc. d.b.a. AEMC Instruments ®...
  • Page 10: Technical And Sales Assistance

    Technical and Sales Assistance If you are experiencing any technical problems or require any assistance with the proper operation or application of your instrument, please call, e-mail or fax our technical support team: Chauvin Arnoux , Inc. d.b.a. AEMC Instruments ®...
  • Page 11: Warranty Repairs

    CSA Form and other required paperwork along with the next steps to complete the request. Then return the instrument along with the signed CSA Form. Please write the CSA# on the outside of the shipping container. Return the instrument, postage or shipment pre-paid to: Chauvin Arnoux , Inc. d.b.a. AEMC Instruments ®...
  • Page 12 12/22 99-MAN 100541 v0 AEMC Instruments ® 15 Faraday Drive • Dover, NH 03820 USA Phone: (603) 749-6434 • (800) 343-1391 • Fax: (603) 742-2346 www.aemc.com © Chauvin Arnoux , Inc. d.b.a. AEMC Instruments. All Rights Reserved. ® ®...