EN 61000-3-11:2000 EN 55014-2:2015 EN 61000-3-3:2013 EN 61000-3-12:2011 EN 61000-3-2:2014 NOISE 200/14/CE HP Models: BWT PEARL HPF 10/13/16/20/24/27 Other normative documents Person authorised to manage technical documentation RoHS 2011/65/EU R&D Department WEEE 2012/19/EU Processing by individuals of electronic appliances reaching the end of their lifespan: The symbol depicting a barred wastebin that features on the main parts constituting the product indicates that it must not be discarded alongside household waste.
Page 4
TECHNICAL SPECIFICATIONS Models BWT PEARL HPF09 BWT PEARL HPF13 BWT PEARL HPF16 BWT PEARL HPF20 BWT PEARL HPF24 BWT PEARL HPF28 Recommended pool size 55-70 m³ 70-85 m³ 85-105 m³ 105-130 m³ 130-160 m³ 30-45 m³ Air 28°C / Water 28°C / 80%HR...
Page 5
Immersion and starting of HP P. 22 P. 22 Settings P. 23 General use P. 23 Regulation (Electronic controller) P. 24 Mobile application : BWT Inverter P. 25 Controller state table P. 26 Maintenance P. 27 Wintering P. 27 Recycling the HP P.
Page 6
This symbol indicates that the device uses R32, a coolant featuring a low combustion speed. This symbol indicates that a maintenance technician must handle this equipment according to the operating manual. This symbol indicates that the operating manual should be read attentively prior to use. WARNING: In normal conditions, a suitable HP can heat the water of the pool by 1°C to 2°C per day.
Page 7
INSTALLATION (SITE, TYPE DE SUPPORT, ESPACE À PRÉVOIR) - Installer la PAC à l' e xtérieur à plus de 2 m du bassin selon les lois en vigueur (NF C 15 100). INSTALLATION (SITE, TYPE OF SUPPORT, NECESSARY SPACE) - Poser la PAC sur ses les plots anti-vibratoires fournis sur une surface stable, solide (pouvant supporter le poids de l'appareil) et de niveau (éventuellement réaliser un socle en béton).
Page 8
HYDRAULIC CONNECTION • Water quality necessary for this device: NF-EN-16713-3 • The HP is compatible with all types of water treatment. The HP must imperatively be connected by a PVC pipe of Ø 50mm to the swimming pool’s hydraulic • circuit, after the filter and before the treatment system, regardless of its type (Cl, pH, Br metering pumps and/or electrolyser).
Page 9
Maximum cable* length with cable sections: Rated residual action Rated current (A) 2,5 mm² 4 mm² 6 mm² 10 mm² current (mA) BWT PEARL HPF 09/ 13 16 A 30 mA 24 m 39 m 56 m 96 m BWT PEARL HPF 16/20...
Page 10
Heating priority (Option): The filtration pump can be connected to the HP to force the filtration to operate if the water is not at the desired temperature. Prior to this connection, a “dry contact” (normally open relay or connector) with a 230V AC coil should be provided. Electrical connections: •...
Page 11
SETTINGS Water flow setting: • To optimise the heating performance and achieve power savings, the flow of water travelling through the HP should be adjusted. • The adjustment is done based on the reading of the adjustment pressure gauge. The adjustment is done by opening or closing the adjustment valve of the bypass.
Page 13
MOBILE APPLICATION : BWT INVERTER This model is equiped with BWT Inverter module allowing the user to control remotely the heat pump and its accessories with BWT Inverter application. BWT Inverter will also allow you to communicate easily with our after sales technicians to solve remotly and quicly some of the machine disfuncions.
Page 14
CONTROLLER STATE TABLE Affichage Explanation Check Solution (if no reset) St-by Stand-by No water flow or the flow - Check if filtration pump is working. Contact your seller switch doesn’t detect the - Check by-pass setting. water flow - Check water flow switch position. AL10 / AL11 HP error AL15 / AL16...
Page 15
MAINTENANCE Before any maintenance operation, the heat pump must be completely stopped for few minutes before connecting pressure controllers. This is because high pressure and temperature inside the heat pump could be harmful. Please check the following on a monthly basis: •...
Page 16
Contact your dealer and pass on this information together with the dimensions of the swimming pool, your personal details (address, telephone number) and the description of the failure. If this procedure is respected, the BWT technician will be able to make as accurate diagnostic of the failure. The recommended solution made by BWT will be implemented briefly after that.
Page 17
Instructions Manual BWT PEARL HPT 09 BWT PEARL HPT 15 BWT PEARL HPT 20...
Page 18
EN 55014-1:2017 EN 61000-3-11:2000 EN 55014-2:2015 EN 61000-3-3:2013 EN 61000-3-12:2011 EN 61000-3-2:2014 NOISE 200/14/CE HP Models: BWT Pearl HPT 09/12/15/18/20 Other normative documents Person authorised to manage technical documentation RoHS 2011/65/EU R&D Department WEEE 2012/19/EU France, 04/2022 Processing by individuals of electronic appliances reaching the end of their lifespan: The symbol depicting a barred wastebin that features on the main parts constituting the product indicates that it must not be discarded alongside household waste.
Page 19
TECHNICAL SPECIFICATIONS BWT PEARL HPT15 Models BWT PEARL HPT09 BWT PEARL HPT20 Recommended pool size 55-70 m³ 35-45 m³ 85-105 m³ Air 26°C / Water 26°C / 80%HR Capacity in MAX Mode 15,3 kW 9,5 kW 20,1 kW COP MAX Mode...
Immersion and starting of HP P. 22 P. 22 Settings P. 23 General use P. 23 Regulation (Electronic controller) P. 24 Mobile application : BWT Inverter P. 25 Controller state table P. 26 Maintenance P. 27 Wintering P. 27 Recycling the HP P.
Page 21
This symbol indicates that the device uses R32, a coolant featuring a low combustion speed. This symbol indicates that a maintenance technician must handle this equipment according to the operating manual. This symbol indicates that the operating manual should be read attentively prior to use. WARNING: In normal conditions, a suitable HP can heat the water of the pool by 1°C to 2°C per day.
INSTALLATION (SITE, TYPE OF SUPPORT, NECESSARY SPACE) • Install the HP outdoors at more than 2 meters from the pool. • Place the HP on the provided vibration absorbers on a surface that is stable, solid (able to bear the weight of the device) and level (prepare a concrete base if necessary).
HYDRAULIC CONNECTION • Water quality necessary for this device: NF-EN-16713-3 • The HP is compatible with all types of water treatment. The HP must imperatively be connected by a PVC pipe of Ø 50mm to the swimming pool’s hydraulic • circuit, after the filter and before the treatment system, regardless of its type (Cl, pH, Br metering pumps and/or electrolyser).
Page 24
Maximum cable* legnht with cable sections: Rated residual action Rated current (A) 2,5 mm² 4 mm² 6 mm² 10 mm² current (mA) BWT PEARL HPT 09 30 mA 43 m 68 m 100 m 170 m BWT PEARL HPT 15 14 A...
Heating priority (Option): The filtration pump can be connected to the HP to force the filtration to operate if the water is not at the desired temperature. Prior to this connection, a “dry contact” (normally open relay or connector) with a 230V AC coil should be provided. Electrical connections: •...
SETTINGS Water flow setting: • To optimise the heating performance and achieve power savings, the flow of water travelling through the HP should be adjusted. • The adjustment is done based on the reading of the adjustment pressure gauge. The adjustment is done by opening or closing the adjustment valve of the bypass.
MOBILE APPLICATION : BWT INVERTER This model is equiped with BWT Inverter module allowing the user to control remotely the heat pump and its accessories with BWT Inverter application. BWT Inverter will also allow you to communicate easily with our after sales technicians to solve remotly and quicly some of the machine disfuncions.
CONTROLLER STATE TABLE Affichage Explanation Check Solution (if no reset) St-by Stand-by No water flow or the flow - Check if filtration pump is working. Contact your seller switch doesn’t detect the - Check by-pass setting. water flow - Check water flow switch position. AL10 / AL11 HP error AL15 / AL16...
MAINTENANCE Before any maintenance operation, the heat pump must be completely stopped for few minutes before connecting pressure controllers. This is because high pressure and temperature inside the heat pump could be harmful. Please check the following on a monthly basis: •...
Contact your dealer and pass on this information together with the dimensions of the swimming pool, your personal details (address, telephone number) and the description of the failure. If this procedure is respected, the BWT technician will be able to make as accurate diagnostic of the failure. The recommended solution made by BWT will be implemented briefly after that.