Omron JX Series Replacing Manual page 31

Simple, compact inverters
Table of Contents

Advertisement

Communication speed
selection
1138h
(Baud rate selection)
Communication station No.
1139h
Communication parity
113Bh
selection
Communication stop bit
113Ch
selection
Communication error
113Dh
selection
Communication error
113Eh
timeout
Communication wait time
113Fh
FV adjustment
1141h
FI adjustment
1142h
UP/DWN selection
1149h
Reset selection
114Ah
Logic operation function A
1150h
input
Logic operation function B
1151h
input
Logic operator selection
1152h
Output terminal P1 ON delay
1153h
Output terminal P1 OFF
1154h
Relay output ON delay
1157h
Relay output OFF delay
1158h
Motor capacity selection
1165h
2nd motor capacity selection
1541h
Motor pole number selection
1166h
2nd motor pole number
1542h
Stabilization parameter
1168h
2nd stabilization parameter
1544h
Enter command
0900h
Please note that 3G3MX2-V1 does not provide the following functions:
Overload limit source selection
2nd overload limit source selection
AM adjustment
Monitor display selection
Overvoltage LAD stop function
Overvoltage LAD stop function level setting
Ready function selection
PID FB upper limit
PID FB lower limit
Operator/ModBus selection
AM offset adjustment
C071
C072
C074
Do not change through ModBus
C075
communication. For setting, refer to
"ModBus Setting" (4-78).
C076
C077
C078
C081
0 ~ 2000
C082
00︓OFF
C101
01︓ON
00: Trip reset at power-on
01: Trip reset when the power is
C102
OFF
02: Enabled only during trip (Reset
when the power is ON.)
00︓RUN/01︓FA1/02︓FA2/03︓
C141
OL/04︓OD/05︓AL/06︓Dc/07︓
FBV/08︓NDc/10︓ODc(使用しない で
C142
ください)/43︓LOC
C143
00︓AND/01︓OR/02︓XOR
C144
C145
0 ~ 1000
C148
C149
00︓0.2/ 02︓0.4/ 04︓0.75/ 06︓
H003
1.5/ 07︓2.2/ 09︓3.7/ 11︓5.5/ 12︓
7.5
H203
H004
2/4/6/8
H204
H006
0. ~ 255.
H206
-
Indefinite value
Function name
144Bh
C071
144Ch
C072
144Eh
C074
144Fh
C075
1450h
C076
1451h
C077
1452h
C078
1455h
C081
0.1[%]
1456h
C082
-
1469h
C101
-
146Ah
C102
1492h
C142
-
1493h
C143
-
1494h
C144
1486h
C130
1487h
C131
0.1[s]
1490h
C140
1491h
C141
1503h
H003
-
2503h
H203
1504h
H004
1[ 極 ]
2504h
H204
1507h
H006
1[%]
2507h
H206
-
0900h
-
3G3JX
Register No.
10BBh
152Ch
10CFh
10D8h
10F5h
10F6h
10F9h
112Eh
112Fh
1137h
1145h
31
03(2400bps)/ 04(4800bps)/
05(9600bps)/ 06(19.2kbps)/
07(38.4kbps)/ 08(57.6kbps)/
09(76.8kbps)/ 10(115.2kbps)
1~247
00: No/ 01: Even/ 02: Odd
1: 1 bit
2: 2 bits
00: Trip
01: Trip after deceleration stop
02: Ignore
03: Free-run stop
04: Deceleration stop
0: Timeout disabled
1 to 9999
0~1000
0~2000
00: Not store frequency data
01: Store frequency data
00: Trip reset at power-on
01: Trip reset at power-off
02: Enabled only during trip (Reset
at power-on)
03: Trip reset only
Same as C021 (Except 33 (LOG1) to
35 (LOG3), 63 (OPO), and 255 (no))
00:AND
01:OR
02:XOR
0~1000
00:0.1/ 01:0.2/ 02:0.4/ 03:0.55/
04:0.75/ 05:1.1/ 06:1.5/ 07:2.2/
08:3.0/ 09:3.7/ 10:4.0/ 11:5.5/
12:7.5/ 13:11.0/ 14:15.0/ 15:18.5
00:2P/ 01:4P/ 02:6P/ 03:8P
04~23:10~48Pは設定しないでください
0~255
1
Parameter No.
b028
b228
b080
b089
b130
b131
b151
C052
C053
C070
C086
-
0.01[s]
1[ms]
0.1[%]
-
-
-
-
0.1[s]
-
-
1[%]
-

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents