Rear blower installation
Hide thumbs Also See for Lopi Answer:

Advertisement

Leyden and Arbor Installation Instructions – Prior to Rev 005
The following instructions are for Leyden and Arbor wood stoves that do not have the built in
thermodisk (serial # 1110-009119 or less for Leyden, serial # 1307-003085 or less for Arbor).
a
1-1/2"
c
Route the wires on the
outside of the stove, behind
the convection jacket.
d
Route the wires from the blower through the hole
in the back of the blower housing. Attach these
wires to the thermodisk wires.
3/8" Wrench
f
Attach the blower to the
stove with the three screws
included with the blower.
Page 5 of 6
Rear Blower Installation Instructions
Bend the legs of the
thermodisk bracket to
make it 1-1/2" deep.
e
Position the blower near the rear of the stove. Tuck all excess wire into the
blower box, making sure it does not contact any moving parts. Make sure when
installing the blower, these wires do not become loose.
Plug the blower in. Do not route the power cord under or over the stove or in a
g
location where it may become damaged.
17601035 - 8/18/10
99000138
b
Tuck the thermodisk into place. It
wedges between the rear heat sheild
and the cast iron firebox.