Download Print this page

Sony CNU-700 Operation Manual page 17

Camera command network unit

Advertisement

Available languages

Available languages

Specifications
General
Power requirements 100 to 240 V AC, 50/60 Hz
Current consumption When connecting twelve
RCP-700-series units using a
BKP-7930: 4.0 A max.
Peak inrush current
(1) Power ON, current probe method:
10 A (100 V), 70 A (240 V)
(2) Hot switching inrush current, measured in
accordance with Europen standard
EN55103-1:
14 A (230 V)
Operating temperature
0°C to 45°C (32°F to 113°F)
Dimensions
424 × 132 × 400 mm (w/h/d)
3
(16
/
Mass
9.5 kg (20 lb 15 oz)
Input and output connectors
CCU 1 through 6
8-pin multiconnector (1
each)
RCP 1 through 6
8-pin multiconnector (1
each)
MSU
8-pin multiconnector (1)
VCS
8-pin multiconnector (1)
AUX 1 and 2
8-pin multiconnector (1
each)
CHARACTER
BNC type (2)
video: 0.7 Vp-p,
sync: 0.3 Vp-p
REFERENCE
BNC type (2)
0.3 Vp-p with loopthrough
output
RS232C
D-sub 9-pin (3)
-AC IN
3-pin (1)
Supplied accessories
Operation Manual (1)
Optional accessories
AC power cord
• For customers in the USA and Canada
Power cord (125 V, 10 A, 2.4 m (8 feet))
(Part No. 1-551-812-1X)
Plug retainer (Part No. 2-990-242-0X)
• For customers in the European countries
Power cord (250 V, 10 A, 2.4 m (8 feet))
(Part No. 1-782-929-1X)
Plug retainer (Part No. 2-990-242-0X)
Design and specifications are subject to change
without notice.
1
3
× 5
/
× 15
/
inches)
4
4
4
15

Advertisement