Drolet Deco Nano Owner's Manual page 26

Table of Contents

Advertisement

• The assembly should be as short and direct as possible between the stove and chimney. The
use of two 45 degree elbows is often preferable to a single 90 degree elbow because less
turbulence is created in the exhaust flow and they result in less horizontal run.
• The minimum overall height of the chimney system, measured from the stove top to the exterior
termination cap of the chimney should be at least 12 ft. (3.66 m). A chimney which is too short
may lack the "tunnel effect" required to obtain a proper draft.
• Maximum number of 90-degree elbows: 2.
• Maximum unsupported horizontal length: 3 ft. (1 m).
• Galvanized flue pipes must not be used because the coatings vaporize at high temperatures
and release dangerous gases. Use black painted flue pipes.
• Flue pipes must be at least 24 gauge in thickness.
• Flue pipe joints should overlap 1 ¼" (30 mm).
• Each joint in the assembly must be fastened with at least three screws.
• The assembly must make allowance for expansion: elbows in assemblies allow for expansion;
straight assemblies should include an inspection wrap with one end unfastened, or a telescopic
section.
• Minimum upward slope towards the chimney: ¼ in/ft. (20 mm/m).
• One end of the assembly must be securely fastened to the flue collar with 3 sheet metal
screws and the other end securely fastened to the chimney.
• There must be provision for cleaning of the pipes, either through a clean out or by removal
of the pipe assembly. Removal of the assembly should not require that the stove be moved.
• The male ends of the sections must be oriented towards the appliance so that falling dust and
condensation stay inside the pipe.
• A flue pipe must never pass through a combustible floor or ceiling or through an attic, roof
space, closet or concealed space. Where passage through a wall or partition of combustible
construction is desired, the installation shall conform to CAN/CSA-B365, Installation Code for
Solid-Fuel-Burning Appliances and Equipment.
• A straight up connector assembly needs either a telescopic length or an inspection wrap (pipe
coupler) to allow it to be assembled and disassembled without moving the stove.
• A straight flue pipe assembly offers the least restriction to gas flow and results in a stronger
draft. Straight assemblies also need less maintenance because there are no corners to collect
creosote.
• The chimney connector must be clean and in good condition.
Page 26
Wood Stove - Owner's Manual

Advertisement

Table of Contents
loading

Table of Contents