MAIN CONTROL
The main control board is very ro bust and is rarely the
cause of system issues. It is impo rtant to fully diagnose
the board fo r any suspected failures befo re attempting
to remo ve the bo ard fo r replacement o r service. Follow
the guidelines belo w to fully test and diagno se the main
control.
Power Fault
If the unit does no t (o r seems to no t) po wer o n, fo llo w the
flo w chart belo w to help diagno se the issue. Before begin­
ning it is important to first verify the unit is no t simply set
to sabbath mode.
Check Voltage
No Voltage
At Wall Outlet
Voltage
Verify Voltage At
Main Control
No Voltage
Voltage Input
Voltage
Check Fuse Fl
No Continuity
For Continuity
Continuity
Connect Test Display
Cycle Power And Check
For Operation
Not Operating
Is the Plunger
__
Switch Operating
Properly?
No
Replace
Plunger Switch
Troubleshooting Extended
Alert Customer
Of Power Failure
Replace
Power Cord
Replace
Fuse
Inspect
Operating -
Customer UI
and Data Cable
Replace Main
Yes
Board
CAUTION
I
A
Precautions must be taken while workin g with
live electrical equipmen t. Be sure to follow
proper safety procedures while performin g tests
on live systems.
REED SWITCH
A reed switch is used to mo nito r do o r state. When the do o r
is clo sed it co mes into contact with the reed which clo ses a
circuit which turns the light and display o ff. When the do o r
is o pen the reed mo ves o utward and o pens the circuit. If
the do o r is left o pen fo r lo nger than 5 minutes the switch
will trigger an erro r co de and set an audible warning.
34