Advertisement

O W N E R ' S G U I D E
O W N E R S G U I D E
M A R V E L P R O F E S S I O N A L U N D E R C O U N T E R R E F R I G E R AT I O N
M A R V E L P R O F E S S I O N A L U N D E R C O U N T E R R E F R I G E R A T I O N
F O R M O D E L # M P C P 4 1 5
F O R M O D E L # M P B V 4 1 5
T H E O R I G I N A L R E F R I G E R AT I O N E X P E R T S S I N C E 1 8 9 2
T H E O R I G I N A L R E F R I G E R A T I O N E X P E R T S S I N C E 1 8 9 2

Advertisement

Table of Contents
loading

Summary of Contents for Marvel MPCP415

  • Page 1 O W N E R ’ S G U I D E O W N E R S G U I D E M A R V E L P R O F E S S I O N A L U N D E R C O U N T E R R E F R I G E R AT I O N M A R V E L P R O F E S S I O N A L U N D E R C O U N T E R R E F R I G E R A T I O N F O R M O D E L # M P C P 4 1 5 F O R M O D E L # M P B V 4 1 5...
  • Page 2 Tech Support: techsupport@marvelrefrigeration.com side near the top. Got a Marvelous Design? MARVEL We would love to see how your Marvel product looks in its new home. Send us photos at marketing@marvelrefriger- ation.com, and we might feature your Marvel home design XXXXXXXXXXXX...
  • Page 3: Table Of Contents

    TABLE OF CONTENTS Tip: Click on any section below to jump directly there Safety Control Operation - Service Important Safety Instructions Thermistor Warranty Installation Unpacking Your Appliance Electrical Cutout & Product Dimensions Installing Your Appliance Side-by-Side & Stacking Installations Door Reversal Integrated Panel Dimensions Integrated Panel Installation Installing The Water Supply...
  • Page 4: Important Safety Instructions Thermistor

    IMPORTANT SAFETY INSTRUCTIONS Important Safety Instructions Warnings and safety instructions appearing in this guide are not meant to cover all possible conditions and situa- tions that may occur. Common sense, caution, and care must be exercised when installing, maintaining, or operat- ing this appliance.
  • Page 5: Unpacking Your Appliance

    UNPACKING YOUR APPLIANCE WARNING CAUTION If the appliance was shipped, handled, or stored in other EXCESSIVE WEIGHT HAZARD than an upright position for any period of time, allow the ap- Use two or more people to move product. pliance to sit upright for a period of at least 24 hours before Failure to do so can result in personal injury.
  • Page 6 ELECTRICAL Electrical Connection A grounded 115 volt, 15 amp dedicated circuit is required. This product is factory equipped with a power supply cord that has a three-pronged, grounded plug. It must be plugged into a mating grounding type receptacle in ac- cordance with the National Electrical Code and applicable Do not remove local codes and ordinances (see figure below).
  • Page 7: Cutout & Product Dimensions

    CUTOUT AND PRODUCT DIMENSIONS ROUGH-IN OPENING DIMENSIONS CABINET DIMENSIONS "A" "B" "C" "D" "E" "F" "G" "H" "J" 15" 24" 14 7/8" /4" to 34 /4" /8" " " 34" to 35" " (38.1 cm) (61 cm) (37.8 cm) (67 cm) (98.7 cm) (44.5 cm) (86.4 to 88.9 cm)
  • Page 8 General Installation INSTALLATION Plug in the power/electrical cord. LEVELING INFORMATION Gently push the unit into position. Be careful not Use a level to to entangle the cord or water and drain lines, if confirm the unit is applicable. level. Level should be placed along top Re-check the leveling, from front to back and side to edge and side edge...
  • Page 9: Side-By-Side & Stacking Installations

    SIDE-BY-SIDE AND STACKING INSTALLATIONS Side-by-Side Installation Hinge-by-Hinge Installation (Mullion) When installing two units hinge-by-hinge, 13/16" (22 mm) Other Site Requirements is required for integrated models. Additional space may be Units must operate from separate, properly grounded elec- needed for any knobs, pulls or handles installed. trical receptacles placed according to each unit's electrical specifications requirements.
  • Page 10: Door Reversal

    DOOR REVERSAL Door Reversing Instructions 1. Open door. 2. Loosen screw #1 and #2 using a Philips Screwdriver on top and bottom hinge. Slide door and remove the door from the unit. Figure 16 3. Once door is removed, using a Philips Screwdriver remove screws from magnet actuator located on inside and bottom of door.
  • Page 11: Integrated Panel Dimensions

    INTEGRATED PANEL DIMENSIONS Clearance Clearance for hinge for hinge at top and at top and bottom bottom Right Hand Hinged Door Left Hand Hinged Door 15" (38.1 cm) wide appliance 15" (38.1 cm) wide appliance ⁄ " (2.9 cm) Left Hand Hinged Door Right Hand Hinged Door 15"...
  • Page 12: Integrated Panel Installation

    INTEGRATED DOOR PANEL INSTALLATION Integrated door panel installation: If you purchased an integrated panel model, your unit is equipped with articulated hinges to allow fully integrated built-in installations. Custom panel thicknesses of ⁄ " (15 mm) and ⁄ " (18 mm) are accommodated. CAUTION It is important to use the factory provided grille that came with the product to assure proper air flow is maintained...
  • Page 13 INTEGRATED DOOR PANEL INSTALLATION WARNING Use extreme caution with the articulated hinges. The hinge is self closing and many pinch points exist prior to built-in installation. Do not remove the cabinet "Z" bracket from the top of the cabinet. Integrated Step 2: Remove the door gasket panel flush With the door laying on a flat surface and starting at a...
  • Page 14 INTEGRATED DOOR PANEL INSTALLATION CAUTION Weight of integrated door panel must not exceed 15 pounds (6.8 kg) for a solid door model or 10 pounds (4.5 kg) for a glass door model. Figure 25a #10 x ⁄ " screw Material Type #10 Wood Screw Hardwood ⁄...
  • Page 15 INTEGRATED DOOR PANEL INSTALLATION Step 5: Assemble lock parts Step 7: Install the door Two (2) lock extensions are provided with the lock. Use Carefully open the top and bottom hinges on the door being the longer extension for ⁄ "...
  • Page 16 A tone will sound for several seconds every minute • will appear in display • Close door to silence alert and reset NOTE towards the selected temperature. Time to reach set point varies based etc. Marvel recommends allowing the unit to reach set points before loading.
  • Page 17 USING YOUR ELECTRONIC CONTROL BrightShield™ This model includes BrightShield™ with Vyv™ Antimicrobial Light Technology. BrightShield™ • • Provides continuous antimicrobial action to keep surfaces clean • • • * Testing on a non-enveloped virus (MS2 bacteriophage) showed a 97.12% reduction in controlled laboratory testing in 8 hours on hard surfaces.
  • Page 18: Installing The Water Supply

    INSTALLING THE WATER SUPPLY Water Supply CAUTION Observe and follow all local building codes when installing this appliance. This ice machine must be connected to a potable cold water supply line. delivering water pressure between a minimum of 20 psi and a maximum of 120 psi. "...
  • Page 19: Installing The Drain Plumbing

    616-754-5601 an appropriate drain and cut to length. CAUTION This drain pump is designed to be installed in Marvel ice machines only and approved for use with water only. WARNING Drain pump vent tube. Electrical Shock Hazard...
  • Page 20: Care And Cleaning

    CARE AND CLEANING Refer to your cleaning solution instructions to determine the proper amount of cleaning solution to add based on evaporator plate. Pour the cleaning the fresh water reservoir. Splash shield Splash shield brackets Lift fascia door up to access evaporator plate Remove all of the ice from...
  • Page 21 If Service is Required: It is strongly recommended to periodically inspect and • please contact your dealer or call Marvel Customer Service at 616-754-5601 for directions on how to obtain warranty coverage in your area. showing signs of corrosion should be replaced.
  • Page 22: Long-Term Storage/Winterization

    LONG TERM STORAGE AND WINTERIZATION water in the ice-making system. CAUTION This ice machine must have all water drained and removed to prevent ice machine damage as well as possible water damage to the surrounding area in freezing conditions. These damages are not covered under warranty. CAUTION Do not use any type of anti-freeze or other solution as a substitution for properly draining the ice machine.
  • Page 23 LONG TERM STORAGE AND WINTERIZATION 7. Disconnect the water valve’s outlet water line to the Reconnect the water valve outlet water line. reservoir and drain the remaining water left in the water Reinstall the ice machine’s access cover. line trap area. Clean and dry the ice machine’s storage bin.
  • Page 24 LONG TERM STORAGE AND WINTERIZATION To Restart the Ice Machine access for the air hose. Reconnect or turn on the water supply line. Apply air pressure (approximately 10 psi) to the end of Reconnect drain tubing if removed. the vent tube which will purge the remainder of the Plug in the power cord to a wall outlet and turn the water from the drain pump and the drain line.
  • Page 25: Obtaining Service

    OBTAINING SERVICE If Service is Required: • If the product is within the first year warranty period please contact your dealer or call Marvel Customer Service at 616.754.5601 for directions on how to obtain warranty coverage in your area. •...
  • Page 26: Troubleshooting

    TROUBLESHOOTING Before You Call for Service WARNING troubleshooting guide below. Locate the problem in the Electrocution Hazard guide and refer to the cause and its remedy before calling • Never attempt to repair or perform maintenance on for service. The problem may be something very simple the appliance until the main electrical power has been disconnected.
  • Page 27 TROUBLESHOOTING Ice Quality Troubleshooting the Drain Pump Is there mineral scale build up on the evaporator NOTE plate If the drain pump reservoir (not the ice machine bin) Is there a high mineral content in the water? The water If the ice machine is not working, check the following: Are food items being stored in the ice bin? Remove •...
  • Page 28: Product Liability

    The part that caused the damage must be returned to Marvel in its entirety. The part must be clearly labeled with the serial number of the unit it was removed from, the date, and the servicer who removed the part.
  • Page 29: Warranty Claims

    Claims must be submitted online at • Final billing - Remodel www. marvelservice . co m Warranty parts will be shipped at no charge after Marvel • 60 day submittal d eadline from date of completed confirms warranty status. Please provide the model, serial service number, part number and part d escription.
  • Page 30: Ordering Replacement Parts

    Warranty parts will be shipped at no charge after Marvel confirms warranty status. Please provide the model, serial number, part number and part description. Some parts will require color or voltage information.
  • Page 31: R600A Specifications

    PERSONNEL DO HOT PUNCTURE REFRIGERANT TUBING refrigeration system. RISK Of FIRE OR EXPLOSION. FIAMHA_ B LE REFRIGERANT USED. CONSULT Never substitute Marvel OEM replacement parts REPAIR IIANUAVOWHER'S GUIDE BEFORE ATTEMPTING TO SERVICE THIS PRODUCT. ALL SAFETY PRECAUTIONS HUST BE FOUOWEO.
  • Page 32 R-600A SPECIFICATIONS/LABELING WARNING R-600a equipped products are labeled (both the unit and the compressor). Only skilled and well trained service technicians permitted to service R-600a equipped products. R-600a is colorless and odorless. All tools and equipment must be approved for use with R-600a refrigerant.
  • Page 33 Evacuate/reclaim via the piecing pliers to ensure the When re-brazing, the system must be purged with dry system is empty of R-600a before any system work is nitrogen and at least one access point open to the performed. atmosphere. When re-brazing, proper ventilation is required along with constant monitoring for the presence of R600a refrigerant.
  • Page 34 The low side of the refrigeration system (evaporator, Proper ventilation during service is required. compressor and suction line) must be leak tested with the compressor off (equalized pressure). Never apply a torch to a charged R-600a refrigeration system. RECHARGING No air is ever to be allowed inside the refrigeration system Use OEM replacement service parts and do not alter the (R-600a refrigerant or dry nitrogen only).
  • Page 35: System Diagnosis Guide

    System Diagnosis Guide REGRIGERATION SYSTEM DIAGNOSIS GUIDE System Suction Suction Compressor Condenser Capillary Evaporator Wattage Condition Pressure Line Discharge Tube Normal Normal Slightly Very hot Very hot Warm Cold Normal below room temperature Overcharge Higher than Very cold Slightly warm Hot to warm Cool Cold...
  • Page 36: Compressor Specifications

    Compressor Specifications FMXA9C REFRIGERANT R600A DANGER VOLTAGE 115 VAC FREQUENCY 60 Hz 5 Ohm at 77 START WINDING ° Electrocution can cause death or serious injury. RUN WINDING 7 Ohm at 77 ° Burns from hot or cold surfaces can cause serious 12 Ohm at 77 °...
  • Page 37 MODEL NUMBER 1. Disconnect the unit from power source. 2. Push and hold the Marvel button. 3. While still holding the Marvel button, plug the unit into the appropriate power source. 4. When the flashing digits appear (3-5 seconds), use the up and down arrow buttons to select the appropriate model number*.
  • Page 38 USER GUIDE u-line.com Control Operation-Service...
  • Page 39 Thermistors Evaporator Thermistor Thermistors are used for various temperature readings. If the evaporator thermistor fails, the unit will rely on a Thermistors provid e reliable temperature readings preset defrost timer during defrost cycles. The unit will using a resistance which varies based on surrounding otherwise operate normally.
  • Page 40 For designated Marvel Professional product, Marvel offers a one year extension of the two year warranty coverage from the date of purchase, free of charge. To take advantage of this third year warranty, you must register your product with Marvel within 60 days from the date of purchase at marvelrefrigeration.com and provide proof of purchase.
  • Page 41 Marvel Refrigeration 1260 E. Van Deinse St. Greenville MI 48838 616.754.5601 41015651 Rev A All specifications and product designs subject to change without notice. Such revisions do not entitle 12/14/20 the buyer to corresponding changes, improvements, additions, replacements or compensation for...

Table of Contents