E5850A Time Correlation Fixture
Quick Start/Installation Guide
The Agilent E5850A time correlation
fixture allows you to make time-correlated
measurements between a 1680/90 or 16700 logic
analyzer and an Agilent 548XX series Infiniium
oscilloscope. The instruments communicate
with one another through a LAN connection
and through the time correlation fixture. The
instruments connect to your target system
(device undertest) through separate probes,
just as when they are used independently.
Waveforms acquired by the oscilloscope can
be displayed on the logic analyzer.
Equipment Supplied
Point-to-point cable
5061-7342
BNC cables (4)
8120-1840
You may use your own BNC
cables or combine two short
cables into a longer one using
the provided connector.
Equipment Required
Agilent 16700-series logic
analysis system, software
version 2.50 or later.
Note: The E5850A Time Correlation Fixture requires a 548xx Infiniium oscilloscope and either a 16700-series logic analysis
system or a 1680/90-series logic analysis system.
E5850A time
correlation fixture
CD-ROMs:
16700 software
Infiniium software update
Documentation
Agilent 548xx Infiniium
oscilloscope, with a probe.
548xxA models require
software version 4.00 or later.
Power supply and power cord
WARNING Shock hazard. Use
!
only the 0950-2546 power supply
Caution Equipment damage. Use
only the 0950-2546 power supply
and cord.
If the cord you received is not
appropriate for your electrical
power outlet type, contact your
Agilent Technologies sales and
service office.
Agilent 1680/90-series logic
analysis system, software
version 1.40 or later.

Advertisement

loading

Summary of Contents for Agilent Technologies E5850A

  • Page 1 548xxA models require version 2.50 or later. version 1.40 or later. software version 4.00 or later. Note: The E5850A Time Correlation Fixture requires a 548xx Infiniium oscilloscope and either a 16700-series logic analysis system or a 1680/90-series logic analysis system.
  • Page 2 If your oscilloscope and logic analyzer are not already connected to a LAN, a simple point-to-point connection may be the most convenient connection between the instruments. Use the cross-over (blue) cable provided with your E5850A. Connect one end of the cable to the network interface on your Infiniium 548xx oscilloscope the and the other end to the network interface on logic analysis system.
  • Page 3 Enter: 192.0.2.231 infiniium. Select Add and OK. Select OK to close the Network Setup dialog. Now when you use the E5850A software, you can enter either infiniium or 192.0.2.231 as the Infiniium Host Name or IP. E5850A Quick Start Guide...
  • Page 4: Install The Software

    If you purchased a 16700-series logic analyzer with the E5850 time correlation fixture, you can skip this step. Insert the 16700 Software CD into the logic analysis system. Click on the following fields to install the E5850A tool software. Double-click to open the AUXILIARY-SW directory.
  • Page 5 Setup Assistant to connect the cables. calibration process. When the calibration is complete, disconnect the scope probe and the logic analyzer leads from the time correlation fixture, but do not disconnect the BNC connections. E5850A Quick Start Guide...
  • Page 6 In the IP Settings all DNS tab, remove any addresses installed gateways. from the list. In the WINS Close the dialogs. tab, remove Click on Yes if all WINS prompted to addresses continue. from the list. E5850A Quick Start Guide...
  • Page 7 Click Finish to add the Infiniium tool to the 1680/90 Overview window. When the calibration is complete, disconnect the scope probe and the logic analyzer leads from the time correlation fixture, but do not disconnect the BNC connections. E5850A Quick Start Guide...
  • Page 8 For More Information 16700-series Logic Analyzer Help Open the Time Correlation Fixture Help from the Infiniium window in the logic analysis system. 1680/90-series Logic Analyzer Help E5850A Quick Start Guide...
  • Page 9: Declaration Of Conformity

    Date: 11/22/2000 Name Ken Wyatt / Product Regulations Manager For further information, please contact your local Agilent Technologies sales office, agent or distributor. Electrical characteristics: power supply Input: 100-240 V, 9.75 A, 50/60 Hz, IEC 320 connector. Output: +5 V, 2.0 A Accessory output: 100-240 V, 9.5 A, 50/60 Hz...
  • Page 10 The mains plug shall only be that its software and firmware translation into a foreign This is the E5850A Time you to refer to the instruction inserted in a socket outlet pro- designated by Agilent...